TITLE

Electron density profile reconstruction from multichannel microwave interferometer data at W7-AS

AUTHOR(S)
Koponen, J.P.T.; Dumbrajs, O.
PUB. DATE
November 1997
SOURCE
Review of Scientific Instruments;Nov97, Vol. 68 Issue 11, p4038
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Studies electron density profile reconstruction methods based on regularization functionals. Multichannel microwave interferometer built for the W7-AS fusion experiment; Temporal phenomena in plasma density; Better results given by the minimum Fisher-information approach; Profiles reconstructed from multichannel interferometer data.
ACCESSION #
4320569

 

Related Articles

  • Density profile reconstructions from 2-D interferometric data on Microtor using novel tomographic analysis techniques (abstract). Howard, J.; Doyle, E. J.; Reibeiz, G.; Savage, R. L.; Peebles, W. A.; Luhmann, N. C. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1592 

    Plasma tomographic reconstructions are subject to aliasing ambiguity as a result of the limited angular and radial sampling rates for the line-integrated data. The two-view interferometer installed on the Microtor tokamak yields unambiguous information, specifically, a collection of six...

  • New type of digital phase linearizer for real-time interferometric measurement. Tokuzawa, T.; Kawahata, K.; Tanaka, K.; Ito, Y.; Ejiri, A.; Simizu, T. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1103 

    A new type of digital phase linearizer has been developed for real-time electron density measurement using a multichannel far-infrared (FIR) interferometer. The phase linearizer can measure phase shifts up to 640 fringes. The size of internal memory is 16 bits-2 Mwords and the sampling frequency...

  • He–Ne interferometer for density measurements in plasma opening switch experiments. Weber, B. V.; Hinshelwood, D. D. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5199 

    A He-Ne interferometer is used to measure the line-integrated electron density in the plasma of an operating plasma opening switch (POS). A heterodyne technique is used, where an acousto-optic modulator generates a 40-MHz frequency shift between the reference and scene beams. The phase shift is...

  • A multichannel interferometer for electron density measurements in COMPASS. Edlington, Trevor; Wylde, Richard // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4968 

    A compact seven channel interferometer has been designed and built to measure electron density profiles in the COMPASS (compact assembly) tokamak. Two far-infrared (FIR) laser cavities are optically pumped with a single continuous-wave CO[sub 2] laser, generating two similar beams at λ = 433...

  • Density profile measurement using a multichannel difluoromethane laser interferometer system on ATF. Ma, C. H.; Baylor, L. R.; Hutchinson, D. P.; Murakami, M.; Wilgen, J. B. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4981 

    Recent results of the electron density profile measurement on the Advanced Toroidal Facility are presented. A multichannel difluoromethane laser interferometer system has been routinely employed to study density evolution in electron cyclotron heated as well as neutral-beam-heated plasma...

  • A two color mm-wave interferometer for the JET divertor. Prentice, R.; Edlington, T.; Smith, R.T.C.; Trotman, D.L.; Wylde, R.J.; Zimmermann, P. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1154 

    Describes an interferometer with compensation for vibration and large scale mechanical movements that was designed and built to measure the line integral electron density along three different lines of sight through the Joint European Torus divertor plasma. General design of the interferometer;...

  • TEXT upgrade far-infrared interferometer system. Hallock, G. A.; Gartman, M. L.; Castles, R. L.; Chiang, K.; Rahman, A. S. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2893 

    A high-resolution 2-D interferometer is being developed to measure electron density profiles in the TEXT-upgrade tokamak. Excellent port access allows both horizontal and vertical chords, which will be used to resolve plasma asymmetries. Close channel spacing is employed to give good spatial...

  • Multichord, near infrared interferometers for the CTX and ZT-40M experiments. Newman, E. W.; Buchenauer, C. J.; Hoida, H. W. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1992 

    A versatile, multichord CO[sub 2] interferometer design with a wide dynamic range is adapted to several different experiments. The systems are double pass, Mach-Zehnder, heterodyne, interferometers [that employ a single germanium Bragg cell and 2[sup n + 1] - l (n is an integer) 50%...

  • CO2 laser interferometer for electron density measurement in JT-60U tokamak. Kawano, Yasunori; Nagashima, Akira; Ishida, Shinichi; Fukuda, Takeshi; Matoba, Tohru // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4971 

    A tangential chord CO[sub 2] laser interferometer for electron density measurement in the JT-60U tokamak is described. To compensate for a phase shift due to mirror vibrations, an IR-HeNe laser interferometer is introduced. Probe beams of the CO[sub 2] and the IR-HeNe lasers travel in a similar...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics