TITLE

Optimization of an ion-optics system with 'thick' electrodes for the diagnostic neutral beam

AUTHOR(S)
Davydenko, V.I.; Ivanov, A.A.; Rogozin, A.I.; Uhlemann, R.
PUB. DATE
March 1997
SOURCE
Review of Scientific Instruments;Mar97, Vol. 68 Issue 3, p1418
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Considers the optimization results of the ion-optics system in a neutral beam injector. Application of beam emission spectroscopy in the TEXTOR tokamak; Neutral beam that the injector is capable of delivering; Simulation results with the AXCEL code for grids of a certain thickness; Estimated temperature rise of the inertially cooled molybdenum grids.
ACCESSION #
4320515

 

Related Articles

  • First results of reverse field experiment vertical time-of-flight. Costa, S.; Murari, A.; Lotto, L. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p607 

    The charge exchange neutral particle outfluxes and ion temperature are important quantities for the determination of the power balances and the plasma’s energetic content; therefore they constitute a long term issue of reversed field pinch research. In order to improve the experimental...

  • In situ calibration of neutral beam port-through power and estimation of neutral beam deposition on LHD. Osakabe, M.; Takeiri, Y.; Tsumori, K.; Murakami, S.; Kaneko, O.; Ikeda, K.; Oka, Y.; Asano, E.; Kawamoto, T.; Akiyama, R.; Kawahata, K.; Komori, A.; Inoue, N.; Yonezu, Y.; Ohyabu, N.; Motojima, O. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p590 

    The neutral beam (NB) shine-through profile is routinely monitored on the Large Helical Device (LHD) both to calibrate the port-through power of the NB and to evaluate the NB-deposition power to LHD plasmas. The profile is measured with a calorimeter (CM) array on an armor plate of the NB...

  • Charge exchange neutral particle analysis with natural diamond detectors on LHD heliotron. Isobe, M.; Sasao, M.; Iiduka, S.; Krasilnikov, A. V.; Murakami, S.; Mutoh, T.; Osakabe, M.; Sudo, S.; Kawahata, K.; Ohyabu, N.; Motojima, O. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p611 

    Semiconductor detectors based on natural diamonds have been installed on the Large Helical Device (LHD) heliotron to measure the energy distribution of charge exchange fast neutral particles from different viewing angles. Advantages of a natural diamond detector (NDD) are (1) very compact size,...

  • A diagnostic neutral beam system for the MST reversed-field pinch. Abdrashitov, G. F.; Davydenko, V. I.; Deichuli, P. P.; Den Hartog, D. J.; Fiksel, G.; Ivanov, A. A.; Korepanov, S. A.; Murakhtin, S. V.; Shulzhenko, G. I. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p594 

    A diagnostic neutral beam system has been developed for the Madison symmetric torus (MST) reversed-field pinch. The system is primarily used: (1) for measurement of the majority ion equilibrium and fluctuating velocity and temperature by Rutherford scattering (RS); (2) for measurement of the...

  • Versatile multiwavelength imaging diagnostic in the MAST spherical tokamak. Patel, A.; Carolan, P. G.; Conway, N. J.; Bunting, C. A.; Akers, R. J. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4145 

    Spectral imaging diagnostics that view the full plasma cross section are used on MAST with sensor resolutions and frame rates of up to 256×512 chords and 130 Hz, respectively. The incident and solid angles of filter illumination are fully controllable. Image splitting and spectral selection...

  • Variable frequency RFQs as cyclotron injectors. Schempp, A. // AIP Conference Proceedings;2001, Vol. 600 Issue 1, p283 

    Injectors for cyclotrons must provide low emittance beams with variable energy and bunch repetition frequency. The parameters of standard RFQs, which are short duty factor and constant operating frequency are not favourable for cyclotron application. Our development of the VE-RFQ has been...

  • Increased performance with 12-mrad sagittal-focusing monochromator. Chung, Ki-Sup; Bai, Jianming; Sparks, Cullie J.; Ice, Gene E. // AIP Conference Proceedings;2000, Vol. 521 Issue 1, p234 

    A recently installed large (20 cm) ribbed crystal located 9.8 m from the source of beamline X14A at the NSLS (National Synchrotron Light Source) is capable of collecting 15 milliradians of horizontal divergence. A nearly linear increase in beam flux and intensity is demonstrated for 6 keV...

  • Dispersion Dilution of the Beam Emittance in Linear High-Energy Electron Accelerators. Tsakanov, V. M. // Technical Physics;Jul2000, Vol. 45 Issue 7, p887 

    Dispersion dilution of the beam emittance in a linear accelerator due to the initial uncorrelated spread of the particle energy in a bunch is considered. Both coherent beam oscillations and the case of the disturbed central trajectory and its local correction are treated. Emphasis is given to...

  • Improvement of beam emittance of the CEA high intensity proton source SILHI. Gobin, R.; Beauvais, P.-Y.; Ferdinand, R.; Leroy, P.-A.; Celona, L.; Ciavola, G.; Gammino, S. // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2652 

    Discusses the improvement of beam emittance of the Commisariat a l'Energie Atomique high intensity proton source SILHI. Beam emittance measurements.