TITLE

A software-controlled analog random pattern generator for space-borne detector simulation

AUTHOR(S)
Chun, H.J.; Thomas, P.D.
PUB. DATE
December 1996
SOURCE
Review of Scientific Instruments;Dec1996, Vol. 67 Issue 12, p4369
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a user-controlled detector simulator to aid development of the grazing incidence spectrometer (GIS), which forms part of the coronal diagnostic spectrometer on-board the solar and heliospheric observatory. Full-range tests of the GIS processing electronics in the absence of real detectors; Performance parameters; Software and hardware design.
ACCESSION #
4320496

 

Related Articles

  • New method of adjusting and aligning a grazing incidence grating spectrometer. Shaotang, He; Yuan, Chen; Shutai, Chunyu; Hansheng, Peng // Review of Scientific Instruments;Jul1993, Vol. 64 Issue 7, p2031 

    A compact grazing incidence grating spectrometer with spectral range of 2-32 nm resolution of 0.0005 nm, and about 3.6-kg weight has been manufactured, which can meet the requirements of current x-ray laser experimental research. During the construction, as a new method, we used a 3D measuring...

  • New spectrometer for grazing exit x-ray fluorescence. Perez, Roberto D.; Sanchez, Hector Jorge // Review of Scientific Instruments;Jul97, Vol. 68 Issue 7, p2681 

    Describes the technical characteristics of one spectrometer developed for surface analysis by using the grazing exit technique. Application of x-ray fluorescence techniques; Description of the spectrometer; Advantages of the grazing x-ray fluorescence.

  • Grazing-incidence spectrometer on the SSPX spheromak. Clementson, J.; Beiersdorfer, P.; Magee, E. W. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10F538 

    The silver flat field spectrometer (SFFS) is a high-resolution grazing-incidence diagnostic for magnetically confined plasmas. It covers the wavelength range of 25–450 Å with a resolution of Δλ=0.3 Å full width at half maximum. The SFFS employs a spherical 1200 lines/mm...

  • Application of bent microchannel plates in recording systems of grazing-incidence spectrometers. Antsiferov, P.; Dorokhin, L.; Sopkin, Yu.; Shevel'ko, A. // Instruments & Experimental Techniques;Sep2015, Vol. 58 Issue 5, p696 

    The design of the grazing-incidence spectrometer, in the scheme of which microchannel plates (MCPs) elastically bent along the Rowland circle are used, is described. This scheme allows one to improve the matching of the spatial resolution of the MCP and the real spectral structure as compared...

  • High-resolution VUV spectrometer/detector investigations of rare-earth pulsed plasma source (abstract). Roberts, J. R.; Cromer, C. L.; Bridges, J. M.; Lucatorto, T. B. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p868 

    A 1.5-m grazing incidence spectrometer with a channel electron multiplier (CEMA) and electronic readout detector has been incorporated with a rare-earth target, pulsed plasma, continuum source. The spectrometer is compact and portable while maintaining high resolution. The CEMA detector consists...

  • Calibration of grazing incidence spectrometers using charge transfer excitation (abstract). Isler, R. C.; Langley, R. A. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p868 

    The sequence of radiative cascades following charge transfer between energetic neutral atoms and C[sup 6+] , N[sup 7+] , and O[sup 8+] are readily observed in high-temperature plasma devices where the field of view of a vacuum spectrometer includes a neutral heating beam. These charge exchange...

  • Flat-field grating spectrometer for high-resolution soft x-ray and extreme ultraviolet measurements on an electron beam ion trap. Beiersdorfer, P.; Magee, E. W.; Trèbert, E.; Chen, H.; Lepson, J. K.; Gu, M.-F.; Schmidt, M. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3723 

    A R=44.3 m grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 up to 50 Ã…. The instrument uses a grating with variable line spacing (about...

  • Triple-path collector optics for grazing incident x-ray emission spectrometer. Tokushima, T.; Horikawa, Y.; Shin, S. // Review of Scientific Instruments;Jul2011, Vol. 82 Issue 7, p073108 

    A new type of collector optics was developed for grazing incident x-ray emission spectrometer. The collector optics used two cylindrical mirrors to add two extra light paths while keeping the center light path that directly illuminates the grating. The design and properties of the spectrometer...

  • High-resolution grazing-incidence grating spectrometer for temperature measurements of low-Z ions emitting in the 100-300 Ã… spectral band. Widmann, K.; Beiersdorfer, P.; Magee, E. W.; Boyle, D. P.; Kaita, R.; Majeski, R. // Review of Scientific Instruments;2014, Vol. 85 Issue 11, p1 

    We have constructed a high-resolution grazing-incidence spectrometer designed for measuring the ion temperature of low-Z elements, such as Li+ or Li2+, which radiate near 199 Ã… and 135 Ã…, respectively. Based on measurements at the Livermore Electron Beam Ion Trap we have shown that the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics