TITLE

Fast pyroelectric detector for broadband radiated power measurements

AUTHOR(S)
Cote, C.; DeSilva, A.W.
PUB. DATE
December 1996
SOURCE
Review of Scientific Instruments;Dec1996, Vol. 67 Issue 12, p4146
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents basic design requirements for pyroelectric detectors to be used effectively when the radiation source emits its power in the vacuum ultraviolet range. Case of a typical plasma in magnetic confinement fusion research; Difficulty associated with the VUV wavelength range; Basic characteristics of the commercial detector.
ACCESSION #
4320456

 

Related Articles

  • Long-range body-heat detector. Iannini, Robert // Electronics Now;Feb1994, Vol. 65 Issue 2, p38 

    Presents a body-heat detector project. Pyroelectric detector component; Operating modes; Parts list; Schematic diagrams; System operation; External controls; Case material; Circuit board assembly; Mechanical assembly; End cap wiring; Electrical test; Instrument housing; Operating instructions.

  • Low-Temperature Time-Resolved Vacuum UV Spectroscopy of Potassium Pentaborate Crystals. Ogorodnikov, I. N.; Pustovarov, V. A.; Kirm, M.; Kruzhalov, A. V.; Isaenko, L. I. // Optics & Spectroscopy;May2002, Vol. 92 Issue 5, p702 

    For the first time, subnanosecond time resolution is attained in the low-temperature (at 7 K) measurements of the photoluminescence (PL) spectra (2-6 eV), the PL excitation spectra (4-32 eV), the PL kinetics, and the reflection spectra (4-21 eV) of undoped potassium pentaborate KB[sub 5]O[sub 8]...

  • Absolute density and reaction kinetics of fluorine atoms in high-density c-C4F8 plasmas. Sasaki, K.; Kawai, Y.; Suzuki, C.; Kadota, K. // Journal of Applied Physics;6/15/1998, Vol. 83 Issue 12, p7482 

    Provides information on a study using vacuum ultraviolet absorption spectroscopy to examine absolute density and reaction kinetics of fluorine (F) atoms in high-density octafluorocyclobutane (c-C4F8) plasmas. Methodology used to conduct the study; Information on the absolute F atom density;...

  • Vacuum ultraviolet pulsed field ionization-photoelectron study of OCS in the energy range of 15–19 eV. Chen, Wenwu; Hochlaf, M.; Rosmus, P.; He, G. Z.; Ng, C. Y. // Journal of Chemical Physics;4/1/2002, Vol. 116 Issue 13, p5612 

    Vacuum ultraviolet pulsed field ionization-photoelectron (PFI-PE) spectra for OCS have been obtained in the energy range 15.0-19.0 eV, covering the vibronic bands of OCS[sup +] (A ²Π, B ²Σ[sup +], and C ²Σ[sup +]). The ionization energies for the formation of the ground...

  • 1.5 kW high-peak-power vacuum ultraviolet flash lamp using a pulsed silent discharge of krypton gas. Kawanaka, J.; Shirai, T.; Kubodera, S.; Sasaki, W. // Applied Physics Letters;12/3/2001, Vol. 79 Issue 23, p3752 

    A 1.5 kW high-peak-power discharge lamp with short emission duration of 140 ns has been developed in the vacuum ultraviolet spectral region. Our numerical calculation ensured that the peak emission at 147 nm was due to singlet excimers ([sup 1]Σ), which were mainly produced via...

  • Size dependence of luminescent properties for hexagonal YBO[sub 3]:Eu nanocrystals in the vacuum ultraviolet region. Wei, Zheng-Gui; Sun, Ling-Dong; Liao, Chun-Sheng; Jiang, Xiao-Cheng; Yan, Chun-Hua; Tao, Ye; Hou, Xue-Ying; Ju, Xin // Journal of Applied Physics;6/15/2003, Vol. 93 Issue 12, p9783 

    The vacuum ultraviolet (VUV) spectra of the nanosized YBO[SUB3]:Eu crystals, which have already been prepared by a more facile sol-gel pyrolysis process at a relatively low annealing temperature in our previous work, were investigated and compared to the bulk synthesized by conventional...

  • X-ray radiation damage and a reliability study on bipolar devices. Boyne, D.; Hsia, L.; Wachnik, R.; Decker, R.; Wasik, C. // Applied Physics Letters;6/10/1991, Vol. 58 Issue 23, p2687 

    Studies the radiation damage and reliability of bipolar transistors using the vacuum ultraviolet storage ring of the National Synchrotron Light Source at the Brookhaven National Laboratory. Exposure of the bipolar devices to x-ray radiation; Measurement of the device parameters before and after...

  • Design and performance of a high-temperature fluorescence cell for discharge and electron-beam... Tiscler, H.; Delaporte, Ph.; Fontaine, B.; Forestier, B.; Sentis, M. // Review of Scientific Instruments;Jul96, Vol. 67 Issue 7, p2453 

    Describes the design and performance for a high-temperature fluorescence cell appropriate for kinetic and spectroscopic studies on electron-beam or electrical-discharge excited species emitting in the vacuum ultraviolet. Investigations on the emission spectra and their temporal behavior of...

  • Vacuum ultraviolet photochemistry of CH[sub 4] and isotopomers. II. Product channel fields and absorption spectra. Wang, Jen-Han; Jen-Han Wang; Liu, Kopin; Kopin Liu; Min, Zhiyuan; Zhiyuan Min; Su, Hongmei; Hongmei Su; Bersohn, Richard; Preses, Jack; Larese, John Z. // Journal of Chemical Physics;9/8/2000, Vol. 113 Issue 10 

    In part I of this work the relative velocities and anisotropies of the atomic H and D fragments from methane photolysis at 10.2 eV were measured. In this paper the relative abundance of the methyl and methylene fragments are reported. A complete set of quantum yields for the different...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics