TITLE

Single layer YBa[sub 2]Cu[sub 3]O[sub 7] radio frequency SQUID magnetometers with direct-coupled

AUTHOR(S)
Zhang, Y.; Kruger, U.; Kutzner, R.; Wordenweber, R.; Schubert, J.; Zander, W.; Sodtke, E.; Braginski, A.I.
PUB. DATE
December 1994
SOURCE
Applied Physics Letters;12/26/1994, Vol. 65 Issue 26, p3380
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Examines the magnetic field resolution of superconducting quantum interference device (SQUID) magnetometers in liquid nitrogen. Attainment of flux noise spectral density in SQUID; Pattern of washer structures by optical lithography; Measurement of SQUID within multilayered mumetal magnetic shielding.
ACCESSION #
4319508

 

Related Articles

  • Low-frequency noise and linearity of a YBa...superconducting quantum interference device... Krey, S.; Barthelmess, H.-J. // Journal of Applied Physics;12/1/1999, Vol. 86 Issue 11, p6602 

    Presents information on a study which investigated the noise and flux sensing area of a field cooled direct current superconducting quantum interference device magnetometer. Application of magnetometer; Use of liquid nitrogen in measuring the noise of the magnetometer.

  • Integrated YBa[sub 2]Cu[sub 3]O[sub 7-x] magnetometer for biomagnetic measurements. Drung, D.; Ludwig, F. // Applied Physics Letters;3/4/1996, Vol. 68 Issue 10, p1421 

    Fabricates direct current superconducting quantum interference device (SQUID) magnetometer using YBa[sub 2]Cu[sub 3]O[sub 7-x] (YBCO)-SrTiO[sub 3]-YBCO multilayer process. Insertion of the SQUID robe in biomagnetic dewar; Observation of biomagnetic measurements for integrated magnetometer;...

  • Transfer function and noise properties of YBa[sub 2]Cu[sub 3]O[sub 7-δ] direct-current superconducting-quantum-interference-device magnetometers with resistively shunted inductances. Kahlmann, F.; Booij, W. E.; Booij, W.E.; Blamire, M. G.; Blamire, M.G.; McBrien, P. F.; McBrien, P.F.; Tarte, E. J.; Tarte, E.J.; Peng, N. H.; Peng, N.H.; Jeynes, C.; Romans, E. J.; Romans, E.J.; Pegrum, C. M.; Pegrum, C.M. // Applied Physics Letters;7/24/2000, Vol. 77 Issue 4 

    Studies the transfer function and noise properties of direct-current superconducting-quantum-interference-device (SQUID) magnetometers with resistively shunted inductances. Maximum voltage modulation depth and calculated values based on the theoretical predictions by Enpuku, et. al.; White...

  • Low 1/f flux noise in sputtered YBa2Cu3O7-x bicrystal dc-superconducting quantum interference... Sarnelli, E.; Camerlingo, C.; Russo, M.; Torrioli, G.; Castellano, M. G. // Journal of Applied Physics;10/15/1997, Vol. 82 Issue 8, p3922 

    Analyzes the YBa2Cu3O7-x bicrystal dc-superconducting quantum interference devices (SQUID) and single layer magnetometers working at 77 K. Different geometrical configurations of SQUID characteristic parameters; Comparison between experimental H values and calculated ones by using Eq; Behavior...

  • High performance dc SQUID magnetometers with single layer YBa[sub 2]Cu[sub 3]O[sub 7-x] flux.... Koelle, D.; Miklich, A.H. // Applied Physics Letters;12/27/1993, Vol. 63 Issue 26, p3630 

    Details the fabrication of direct current (dc) superconducting quantum interference device (SQUID) magnetometers with single film YBa[sub 2]Cu[sub 3]O[sub 7-x] flux transformers. Attachment of the transformer to a loop directly coupled to a dc SQUID; Values of the lowest magnetic field noise...

  • Axial high-temperature superconducting-quantum-interference-device gradiometer composed of magnetometers with a monolithic feedback and compensation coil. Yokosawa, Koichi; Oyama, Hiroshi; Kuriki, Shinya; Suzuki, Daisuke; Tsukada, Keiji // Applied Physics Letters;4/30/2001, Vol. 78 Issue 18, p2745 

    A first-order axial gradiometer has been constructed using two high-critical-temperature superconducting-quantum-interference-device magnetometers having a double-pickup loop configuration on bicrystal substrates. The magnetometer, which had a slot-type structure but no weak links on the pickup...

  • Low noise YBa[sub 2]Cu[sub 3]O[sub 7-x] SQUID magnetometers operated with additional positive.... Drung, D.; Dantsker, E.; Ludwig, F.; Koch, H.; Kleiner, R.; Clarke, John; Krey, S.; Reimer, D.; David, B.; Doessel, O. // Applied Physics Letters;3/25/1996, Vol. 68 Issue 13, p1856 

    Presents a low noise YBa[sub 2]Cu[sub 3]O[sub 7-x] superconducting quantum interference devices magnetometers operated with additional positive feedback. Use of flux locked loop; Obtainment of high quality magnetocardiograms.

  • Unlocked detection of SQUID signals: Theory and design. Dubuc, C.; Benhida, K.; Bloyet, D. // Review of Scientific Instruments;May91, Vol. 62 Issue 5, p1333 

    We describe the principle and implementation of a new unlocked processing of SQUID signals. A digital interpolation is achieved by using the periodicity of the voltage-flux transfer characteristic. The method is analyzed and the choice of the main parameters is discussed. A practical...

  • A miniature magnetometer based on the superconducting quantum interference device with direct... Polushkin, V.; Wallis, M.; Glowacka, D.; Matthews, A.; Lumley, John M. // Review of Scientific Instruments;Mar97, Vol. 68 Issue 3, p1461 

    Develops a novel miniature superconducting quantum interference device magnetometer with direct readout electronics. High flux-to-voltage transfer factor achieved without additional positive feedback; Flux resolution corresponding to a magnetic moment sensitivity; Study of the dynamic...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics