Efficacy of Intraoperative Neurologic Monitoring in Surgery Involving a Vertical Expandable Prosthetic Titanium Rib for Early-Onset Spinal Deformity

Skaggs, David L.; Choi, Paul D.; Rice, Christie; Emans, John; Song, Kit M.; Smith, John T.; Campbell Jr., Robert M.
July 2009
Journal of Bone & Joint Surgery, American Volume;Jul2009, Vol. 91-A Issue 7, p1657
Academic Journal
Background: The vertical expandable prosthetic titanium rib (VEPTR) device is used in the treatment of thoracic in- sufficiency syndrome and certain types of early-onset spinal deformity. The purpose of this study was to evaluate the risk of neurologic injury during surgical procedures involving use of the VEPTR and to determine the efficacy of intraoperative spinal cord neuromonitoring. Methods: Data were collected prospectively during a multicenter study. Surgical procedures were divided into three categories: primary device implantation, device exchange, and device lengthening. Further retrospective evaluation was undertaken in cases of neurologic injury or changes detected with neuromonitoring. Results: There were 1736 consecutive VEPTR procedures at six centers: 327 (in 299 patients) consisted of a primary device implantation, 224 were a device exchange, and 1185 were a device lengthening. Perioperative clinical neurologic injury was noted in eight (0.5%) of the 1736 cases: these injuries were identified after five (1.5%) of the 327 procedures for primary device implantation, three (1.3%) of the 224 device exchanges, and none of the 1185 device-lengthening procedures. Of the eight cases of neurologic injury, six involved the upper extremity and two involved the lower extremity. The neurologic deficit was temporary in seven patients and permanent in one patient, who had persistent neurogenic arm and hand pain. lntraoperative neuromonitoring demonstrated changes during six (0.3%) of the 1736 procedures: five (1.5%) of the 327 procedures for primary device implantation and one (0.08%) of the 1185 device-lengthening procedures. The surgery was altered in all six cases, with resolution of the monitoring changes in five cases and persistent signal changes and a neurologic deficit (upper-extremity brachial plexopathy) in one. Two patients had false-negative results of monitoring of somatosensory evoked potentials, and one had false-negative results of monitoring of somatosensory evoked potentials and motor evoked potentials during implant surgery; two had a brachial plexopathy and one had monoplegia postoperatively, with all three recovering. Conclusions: Neurologic injury during VEPTR surgery occurs much more frequently in the upper extremities than in the lower extremities. The rates of potential neurologic injuries (neurologic injuries plus instances of changes detected by monitoring) during primary implantation of the VEPTR (2.8%) and during exchange of the VEPTR (1.3%) justify the use of intraoperative neuromonitoring of the upper and lower extremities during those procedures. As neuromonitoring did not demonstrate any changes in children without a previous VEPTR-related monitoring change and there were no neurologic injuries during more than 1000 VEPTR-lengthening procedures, intraoperative neuromonitoring may not be necessary during those procedures in children without a history of a neurologic deficit during VEPTR surgery.


Related Articles

  • Preparation of Biocompatible Inorganic Materials for the Replacement of Hard Tissues. Nixon, Malcolm // Japanese Biotechnology & Medical Technology;Apr/May2001, Vol. 1 Issue 2, p18 

    Discusses research being done on the construction of an artificial hard tissue material made of hydroxyapatite and a titanium frame.

  • Potential Neurological Risk during a Titanium Rib Procedure and Appropriate Intraoperative Neurophysiologic Monitoring Modalities. Roper, Megan T. // American Journal of Electroneurodiagnostic Technology;Sep2010, Vol. 50 Issue 3, p199 

    The titanium rib procedure is a safe and effective way of surgically treating pediatric patients with thoracic insufficiency syndrome and scoliosis. As with any invasive surgical procedure, it is not without risks. This article explains the potential risks to neurological structures while...

  • Improvement of the Surface Quality of the Medical Prostheses in High Speed Milling. Daymi, A.; Boujelbene, M.; Amara, A. Ben; Linares, J. M. // International Review of Mechanical Engineering;Sep2009, Vol. 3 Issue 5, p566 

    The surface quality of the orthopedic prostheses is a parameter influencing in their life time. The wear of the parts in contact generates particles of metal or plastic in the body of the person who carries this prosthesis. In order to decrease the rate of particles in the body of the carrier,...

  • Foamy titanium gives bone regrowth a boost. Condliffe, Jamie // New Scientist;10/2/2010, Vol. 208 Issue 2780, p01 

    The article reports on research conducted by Peter Quadbeck and colleagues of the Fraunhofer Institute for Manufacturing Technology and Advanced Materials Research in Dresden, Germany, wherein they created a titanium implant suitable for replacing and strengthening damaged bones that possesses a...

  • Medical image based, preformed titanium membranes for bone reconstructions: design study and first clinical evaluation. Pattijn, V; Samson, I; Vander loten, J; Van Audekercke, R; Swaelens, B; De Buck, V // Proceedings of the Institution of Mechanical Engineers -- Part H;Jan2002, Vol. 216 Issue 1, p13 

    The currently used intralesional or marginal surgical treatment of a bone tumour in the extremities shows some shortcomings in providing a restoration of the mechanical strength of the bone and the containment of the used filling materials. The use of a medical image based, preformed and...

  • Rapid Prototyping Advances Medical Bone Implant Technology.  // Foundry Management & Technology;Jan2002, Vol. 130 Issue 1, p96 

    Discusses the rapid prototyping of titanium casting for application as titanium bone implants. Creation of complex and exact replicas of human structures; Stages to the production of titanium implants; Limitations to the implant production via rapid prototyping.

  • Biomechanical rationale and evaluation of an implant system for rib fracture fixation. Bottlang, M.; Walleser, S.; Noll, M.; Honold, S.; Madey, S.; Fitzpatrick, D.; Long, W. // European Journal of Trauma & Emergency Surgery;Oct2010, Vol. 36 Issue 5, p417 

    Background: Biomechanical research directed at developing customized implant solutions for rib fracture fixation is essential to reduce the complexity and to increase the reliability of rib osteosynthesis. Without a simple and reliable implant solution, surgical stabilization of rib fractures...

  • Surgical treatment of scoliosis: a review of techniques currently applied. Maruyama, Toru; Takeshita, Katsushi // Scoliosis (17487161);2008, Vol. 3, Special section p1 

    In this review, basic knowledge and recent innovation of surgical treatment for scoliosis will be described. Surgical treatment for scoliosis is indicated, in general, for the curve exceeding 45 or 50 degrees by the Cobb's method on the ground that: 1) Curves larger than 50 degrees progress even...

  • Results of the spine-to-rib-cage distraction in the treatment of early onset scoliosis. Teli, Marco; Lovi, Alessio; Brayda-Bruno, Marco // Indian Journal of Orthopaedics;Jan-Mar2010, Vol. 44 Issue 1, p23 

    Background: Growing rod systems have been used in the last 30 years for the treatment of early onset scoliosis (EOS) with variable success rates. We report the results of treatment of EOS with a newly developed hybrid rod distraction system applied to the rib cage and spine with a nonfusion...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics