TITLE

Levitation apparatus for structural studies of high temperature liquids using synchronization

AUTHOR(S)
Krishnan, Shankar; Felten, John J.; Rix, James E.; Weber, J.K. Richard; Nordine, Paul C.; Beno, Mark A.; Ansell, S.; Price, D.L.
PUB. DATE
September 1997
SOURCE
Review of Scientific Instruments;Sep97, Vol. 68 Issue 9, p3512
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses the development of a levitation apparatus coupled to a synchrotron-derived x-ray source to study the structure of liquids at temperatures up to 3000 K. Description of the apparatus; Gas flow and vacuum system; Temperature measurements and gradients; Specimen viewing and positioning.
ACCESSION #
4303440

 

Related Articles

  • Kinematic mounting systems for National Synchrotron Light Source beamlines and experiments. Oversluizen, Tom; Stoeber, Walter; Johnson, Erik D. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1285 

    Methods for kinematically mounting equipment are well established, but applications at synchrotron radiation facilities are subject to constraints not always encountered in more traditional laboratory settings. Independent position adjustment of beamline components can have significant benefits...

  • Characterization of platinum–carbon, tungsten–silicon, and tungsten–B4C multilayers. Yamashita, K.; Watanabe, M.; Matsudo, O.; Yamazaki, J.; Hatsukade, I.; Ishigami, T.; Takahama, S.; Tamura, K.; Ohtani, M. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1217 

    Multilayers of Pt/C, W/Si, and W/B[sub 4]C have been developed as a reflector and dispersive element to be applied to the beamline optical system of the synchrotron radiation (SR) in 1- to 20-A region. Pt/C(2d = 105 A, N = 10) overcoated with Pt(d = 100 A) is useful in a glazing incidence...

  • Normal Incidence Reflectometry of Concave Multilayer Mirrors Using Synchrotron Radiation to Evaluate the Period Thickness Distribution. Hatano, Tadashi; Kubota, Shogo; Adachi, Yasunobu; Tsura, Toshihide; Yamamoto, Masaki; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p839 

    For the purpose of fabricating curved multilayer mirrors, we developed an ion beam sputtering deposition system with a programmable shutter for thickness distribution control. In this report we fabricated a Mo/Si multilayer concave mirror of a 100 mm diameter and a 300 mm radius of curvature to...

  • Advantages of combined μ-XRF and μ-XRD for phase characterization of Ti–B–C ceramics compared with conventional X-ray diffraction. Jaroszewicz, Jakub; De Nolf, Wout; Janssens, Koen; Michalski, Andrzej; Falkenberg, Gerald // Analytical & Bioanalytical Chemistry;Jun2008, Vol. 391 Issue 4, p1129 

    Design and processing of new materials with improved high-temperature properties is one of the most challenging tasks of modern engineering. Among such materials, nonoxidic ceramics hold an important place. When optimizing the synthesis conditions of these new materials in an largely empirical...

  • Status of R&Ds for Undulators with Bulk High Temperature Superconductors. Tanaka, T.; Tsuru, R.; Seike, T.; Hirano, H.; Morita, M.; Teshima, H.; Nariki, S.; Sakai, N.; Hirabayashi, I.; Murakami, M.; Kitamura, H. // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p297 

    Utilization of superconducting permanent magnets is now under investigation at SPring-8 for future development of synchrotron radiation sources, and several concepts has been reported so far. In one of them, ring-shaped bulk superconductors (ring SCs) will be used for enhancement of the...

  • An Electron-Beam Profile Monitor Using Fresnel Zone Plates. Nakamura, Norio; Sakai, Hiroshi; Iida, Kensuke; Shinoe, Kenji; Takaki, Hiroyuki; Fujisawa, Masami; Hayano, Hitoshi; Muto, Toshiya; Nomura, Masaharu; Kamiya, Yukihide; Koseki, Tadashi; Amemiya, Yoshiyuki; Aoki, Nobutada; Nakayama, Koichi; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p545 

    We have developed a beam profile monitor using two Fresnel zone plates (FZPs) at the KEK-ATF (Accelerator Test Facility) damping ring to measure small electron-beam sizes for low-emittance synchrotron radiation sources. The monitor has a structure of an X-ray microscope, where two FZPs...

  • Upgrade of BPM Electronics for the SPring-8 Storage Ring. Sasaki, Shigeki; Fujita, Takahiro; Shoji, Masazumi; Takashima, Takeo // AIP Conference Proceedings;2006, Vol. 868 Issue 1, p463 

    SPring-8, a 3rd generation synchrotron light source, has operated since 1997. Improvement of BPM performance is required as a part of upgrading activities of the storage ring as a light source. We have developed new electronics circuits for signal processing of the storage ring BPM, with target...

  • The Main Injector Beam Position Monitor Front-End Software. Piccoli, Luciano; Foulkes, Stephen; Votava, Margaret; Briegel, Charles // AIP Conference Proceedings;2006, Vol. 868 Issue 1, p411 

    The front-end software developed for the Main Injector (MI) BPM upgrade is described. The software is responsible for controlling a VME crate equipped with a Motorola PowerPC board running the VxWorks operating system, a custom-made timing board, and up to 10 commercial digitizer boards. The...

  • In-Air X-Ray Detectors : A New Field of Simple and Powerful Beam Diagnostics. Scheidt, Kees // AIP Conference Proceedings;2006, Vol. 868 Issue 1, p208 

    Crotch or beamport absorbers deal with the unused power of the synchrotron radiation generated by dipoles in electron storage rings. A tiny fraction of the very hard X-rays fully penetrate the absorber structure and enter the free air space behind it. Both at the ESRF (6GeV) and at ANKA (2.5GeV)...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics