ABSTRACT
Describes the in situ calibration of microchannel-plate (MCP)-based x-ray pinhole camera for observation of magnetically trapped plasma. Description of the experimental configuration and the structure of the pinhole camera system; Nonlinear response of the MCP; Correction of an observed two-dimensional image of the soft x-ray emission from the hot plasma.
ACCESSION #
4303422

 

Related Articles

  • Introducing minimum Fisher regularisation tomography to AXUV and soft x-ray diagnostic systems of the COMPASS tokamak. Mlynar, J.; Imrisek, M.; Weinzettl, V.; Odstrcil, M.; Havlicek, J.; Janky, F.; Alper, B.; Murari, A.; JET-EFDA Contributors // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10E531 

    The contribution focuses on plasma tomography via the minimum Fisher regularisation (MFR) algorithm applied on data from the recently commissioned tomographic diagnostics on the COMPASS tokamak. The MFR expertise is based on previous applications at Joint European Torus (JET), as exemplified in...

  • Design and initial operation of multichord soft x-ray detection arrays on the STOR-M tokamak. Xiao, C.; Niu, T.; Morelli, J. E.; Paz-Soldan, C.; Dreval, M.; Elgriw, S.; Pant, A.; Rohraff, D.; Trembach, D.; Hirose, A. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E926 

    Two miniature pinhole camera arrays for spatially and temporally resolved measurements of soft x-ray emission have been designed and installed on the STOR-M tokamak. Each array consists of a photodiode array, with one array viewing vertically and one viewing horizontally through a plasma cross...

  • Measurements of the Power and Energy Spectrum of Radiation of the Plasma Liners. Sorokin, S. A.; Chaıkovsky, S. A. // Technical Physics;Apr2000, Vol. 45 Issue 4, p458 

    A diagnostic complex based on bolometers and X-ray diodes is developed and tested. The complex is designed for measurements of the power and the energy spectrum of the pulses of soft X-rays in a quanta energy range of 70–1500 eV. Both thin films and filters formed by pulsed gas-puff in...

  • High repetitive plasma x-ray source produced by a zigzag slab laser. Zeng, Guan-ming; Takahashi, Masao; Daido, Hiroyuki; Kanabe, Tadashi; Aritome, Hiroaki; Nakatsuka, Masahiro; Nakai, Sadao // Journal of Applied Physics;4/15/1990, Vol. 67 Issue 8, p3597 

    Presents a study which investigated the laser-generated plasma x-ray properties in the soft x-ray region. Experimental details; Results and discussion; Conclusions.

  • Submillimeter high brightness pulsed x-ray source. Lau, J. H. W.; Kekez, M. M.; Lougheed, G. D.; Gupta, R. P. // Applied Physics Letters;6/20/1988, Vol. 52 Issue 25, p2111 

    By inducing an electrical discharge in an annular gas plenum connected to a vacuum diode by a narrow annular slit, we demonstrate that microgram preionized plasma liners can be formed and imploded by a dc charged Blumlein pulser to efficiently convert electrical energy into soft x rays. The...

  • Calibration of a high resolution grating soft x-ray spectrometer. Magee, E. W.; Dunn, J.; Brown, G. V.; Cone, K. V.; Park, J.; Porter, F. S.; Kilbourne, C. A.; Kelley, R. L.; Beiersdorfer, P. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E314 

    The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 Ã… waveband at the Lawrence Livermore National...

  • Fast soft x-ray images of magnetohydrodynamic phenomena in NSTX. Bush, C. E.; Stratton, B. C.; Robinson, J.; Zakharov, L. E.; Fredrickson, E. D.; Stutman, D.; Tritz, K. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E928 

    A variety of magnetohydrodynamic (MHD) phenomena have been observed on NSTX. Many of these affect fast particle losses, which are of major concern for future burning plasma experiments. Usual diagnostics for studying these phenomena are arrays of Mirnov coils for magnetic oscillations and p-i-n...

  • Multicolor, time-gated, soft x-ray pinhole imaging of wire array and gas puff Z pinches on the Z and Saturn pulsed power generators. Jones, B.; Coverdale, C. A.; Nielsen, D. S.; Jones, M. C.; Deeney, C.; Serrano, J. D.; Nielsen-Weber, L. B.; Meyer, C. J.; Apruzese, J. P.; Clark, R. W.; Coleman, P. L. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E906 

    A multicolor, time-gated, soft x-ray pinhole imaging instrument is fielded as part of the core diagnostic set on the 25 MA Z machine [M. E. Savage et al., in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, New York, 2007), p. 979] for studying intense wire array and gas puff...

  • Resonance cones in non-Maxwellian plasmas. Oelerich-Hill, G.; Piel, A. // Physics of Fluids B: Plasma Physics;Feb89, Vol. 1 Issue 2, p275 

    Resonance cones are studied experimentally in hot drifting plasmas and in various beam–plasma situations. In a drifting plasma the upstream–downstream asymmetry of the main cone is suitable for diagnostics of plasma drifts. The evaluation of electron temperature from the...

Share

Read the Article

Courtesy of MICHIGAN ELIBRARY

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics