TITLE

A modified stopped-flow apparatus for time-resolved protein phosphorescence

AUTHOR(S)
Strambini, Giovanni B.; Puntoni, Alessandro; Gonnelli, Margherita
PUB. DATE
December 1997
SOURCE
Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4583
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a modified stopped-flow apparatus for time-resolved protein phosphorescence. Synchronization of laser excitation, fluorescence integration and data acquisition; Protocol for effective deoxygenation of the sample; Time resolution of phosphorescence detection.
ACCESSION #
4302407

 

Related Articles

  • A rapid quenched-flow device for the study of homogeneous polymerization kinetics. White, Curtis B.; Rosaaen, Kimberly A.; Landis, Clark R. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p411 

    We have designed and constructed a device, the rapid flow mixer (RFM), for investigating the kinetics of metallocene-catalyzed alkene polymerization reactions. The RFM operates over a wide range of reaction conditions (temperatures from -40 to 150 °C and pressures up to 500 psi) and has...

  • An improved leaping detector for flow analysis applied to iron speciation in drugs. Santos, Sergio R. B.; Araujo, Mario C. U.; Honorato, Ricardo S.; Zagatto, Elias A. G.; Lima, Jose F. C.; Lapa, Rui A. S. // Journal of Automated Methods & Management in Chemistry;May-Jun2000, Vol. 22 Issue 3, p83 

    A low inner volume (ca. 64 ml) probe was built up in an injector-commutator in order to behave as a photometric leaping detector in flow analysis. It comprises a bicolour light-emitting diode (BLED), as a source of pulsed radiation in the red and green visible region, and two phototransistors as...

  • Sequential determination of free and total cyanide by flow injection. Angelica, Maria; Marin, Bonadiman; Ganzarolli, Edgard Moreira; Lehmkuhl, Arilson; Souza, Ivan Goncalves De; Roosevelt, Roldao; Queiroz, Urzedo De // Journal of Automated Methods & Management in Chemistry;Jan1999, Vol. 21 Issue 1, p23 

    This study presents a flow injection system for the sequential determination of free (CN-) and total (CN- HCN) cyanide using a potentiometric method which employs two different processes for the determination of these two chemical species. The first process is based on direct detection of CN-...

  • A submersible battery-powered flow injection (FI) sensor for the determination of nitrate in estuarine and coastal waters. David, Anthony R. J.; McCormack, Trevor; Worsfold, Paul J. // Journal of Automated Methods & Management in Chemistry;Jan1999, Vol. 21 Issue 1, p1 

    The design, construction and performance of a remotely deployed submersible flow injection-based nutrient (total oxidized nitrogen) sensor are described. The sensor featured a custom-built microcomputer and a solid-state, flow-through spectrophotometric detector, and the derivatization chemistry...

  • Precise TOC Analysis - the Right Injection Technique Makes the Difference.  // Asian Environmental Technology;Aug/Sep2014, Vol. 18 Issue 3, p6 

    The article offers brief information on the multi N/C flow injection system from Analytik Jena AG, provider of analytical, bioanalytical and optical systems for industrial and scientific applications.

  • Optimization of an automated FI-FT-IR procedure for the determination of o-xylene, toluene and ethyl benzene in n-hexane. Wells, Ian; Worsfold, Paul J. // Journal of Automated Methods & Management in Chemistry;Jul1999, Vol. 21 Issue 4, p113 

    The development and optimization of an automated flow injection (FI) manifold coupled with a Fourier transform infrared (FTIR) detector for the determination of toluene, ethyl benzene and oxylene in an n-hexane matrix is described. FT-IR parameters optimized were resolution and number of...

  • TEST AND SIDEDRESS THE SAME DAY. RUEN, JIM // Corn & Soybean Digest;Apr2013, Vol. 73 Issue 5, p12 

    The article focuses on the rapid field moist sample analysis by Solum through its soil laboratory in Ames, Iowa. Until the 1980s, field moist sampling was used. The test is being offered by the Iowa State University (ISU). Several types of equipment that change the approach in soil testing...

  • Design and development of an automated flow injection instrument for the determination of arsenic species in natural waters. Hanrahan, Grady; Fan, Tina K.; Kantor, Melanie; Clark, Keith; Cardenas, Steven; Guillaume, Darrell W.; Khachikian, Crist S. // Review of Scientific Instruments;Oct2009, Vol. 80 Issue 10, p104101 

    The design and development of an automated flow injection instrument for the determination of arsenite [As(III)] and arsenate [As(V)] in natural waters is described. The instrument incorporates solenoid activated self-priming micropumps and electronic switching valves for controlling the...

  • Aspects of signal processing in flow-injection systems. van Staden, Jacobus F. // South African Journal of Chemistry;Jun95, Vol. 48 Issue 1/2, p8 

    Describes various techniques in signal processing for filtering of noise in a detection system in flow-injection analysis. Background on the study; Data acquisition; Noise filtering of signals; Transformation of signals; Calibration techniques; Response surface mapping.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library