TITLE

An ac microcalorimeter employing a diode laser as a heater

AUTHOR(S)
Marone, M.J.; Payne, J.E.
PUB. DATE
December 1997
SOURCE
Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4516
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes an ac microcalorimeter which uses a diode laser as the heater. Reduction of the total addendum; Advantages offered by the method; Modulation of the laser by a lock-in amplifier; Usefulness of the device in the study of whiskers and other small samples.
ACCESSION #
4302395

 

Related Articles

  • Charge collection and thermalization in a composite calorimetric and ionization x-ray detector. Stahle, C. K.; Wouters, J.; Kelley, R. L.; Moseley, S. H.; Szymkowiak, A. E. // Journal of Applied Physics;4/15/1994, Vol. 75 Issue 8, p3723 

    Focuses on a study which developed a combination calorimetric and ionization x-ray detector by attaching a silicon p-i-n diode to a monolithic silicon microcalorimeter. Description of device and measurement apparatus; Diagram of calorimeter electronics and ionization detector electronics;...

  • An electromagnetic calorimeter for the silicon detector concept. Brau, J. E.; Frey, R. E.; Strom, D.; Breidenbach, M.; Freytag, D.; Graf, N.; Haller, G.; Herbst, R.; Jaros, J.; Nelsen, T.; Radeka, V.; Holbook, B.; Lander, R.; Tripathi, M.; Karyotakis, Y. // Pramana: Journal of Physics;Dec2007, Vol. 69 Issue 6, p1025 

    A silicon-tungsten calorimeter for silicon detector (SiD) at the International Linear Collider is under development. Recent progress is summarized.

  • Calorie monitors. GERACI, RON // Men's Health;Dec98, Vol. 13 Issue 10, p46 

    Introduces several caloric consumption monitors. Polar SmartEdge; IM Systems BioTrainer; Casio Personal Trainer Watch; Features of the products; Prices.

  • Thermal-response time of superconducting transition-edge microcalorimeters. Irwin, K.D.; Hilton, G.C.; Wollman, D.A.; Martinis, John M. // Journal of Applied Physics;4/15/1998, Vol. 83 Issue 8, p3978 

    Provides information on the investigation of the limits on the thermal-response time of superconducting transition-edge microcalorimeters. Information on thermalization and diffusion; Detailed information on transition-edge sensor (TEST bias and electrothermal feedback; Conclusions reached on...

  • Status of the endcap BGO calorimeter of the CMD-3 detector. Akhmetshin, R. R.; Grigoriev, D. N.; Kazanin, V. F.; Tsaregorodtsev, S. M.; Yudin, Yu. V. // Physics of Atomic Nuclei;Mar2009, Vol. 72 Issue 3, p477 

    The electromagnetic endcap BGO calorimeter of the CMD-3 detector is ready for experiments at the new e+ e− collider VEPP-2000. Light readout is performed by silicon photodiodes. A thermalcontrol system that is able to maintain the calorimeter temperature at a level of 12 ±1°C was...

  • Anomalous Thermal Behavior in Microcalorimeter Gamma-Ray Detectors. Horansky, Robert D.; Beall, James A.; Irwin, Kent D.; Ullom, Joel N. // AIP Conference Proceedings;12/16/2009, Vol. 1185 Issue 1, p733 

    Improving the resolution of gamma-ray detectors is important for many fields, including determinations of the Lamb shift in atoms with high atomic numbers, nuclear treaty verification, and environmental monitoring. High-purity germanium detectors are currently the tool of choice for precision...

  • The effect of energy stabilization of an ion beam formed by a self-magnetically insulated diode. Pushkarev, A.; Isakova, Yu.; Khailov, I. // Instruments & Experimental Techniques;Jan2015, Vol. 58 Issue 1, p90 

    The results of a study of the generation stability of intense pulsed ion beams, which are formed by a self-magnetically insulated diode with an explosive-emission cathode, are presented. Investigations were conducted using a TEMP-4M accelerator configured to operate in the bipolar pulse mode:...

  • Ultra-high Resolution Alpha Particle Spectrometry with Transition-Edge Sensor Microcalorimeters. Croce, M.; Bacrania, M.; Bond, E.; Dry, D.; Moody, W.; Rabin, M.; Bennett, D.; Hilton, G.; Horansky, R.; Kotsubo, V.; Schmidt, D.; Ullom, J.; Vale, L.; Cantor, R. // Journal of Low Temperature Physics;Jun2012, Vol. 167 Issue 5/6, p955 

    Alpha particle spectrometry is a powerful analytical tool for nuclear forensics and environmental monitoring. Microcalorimeter detectors have been shown to yield nearly an order of magnitude better energy resolution (1.06 keV FWHM at 5.3 MeV) than current state-of-the-art silicon detectors (8-10...

  • Design and experience of using light-emitting diodes (LEDs) as the inbuilt light source for a customised differential photomicrocalorimeter. Mukhanov, V. S.; Kemp, R. B. // Journal of Thermal Analysis & Calorimetry;Mar2009, Vol. 95 Issue 3, p731 

    In the photomicrocalorimetric module designed by Johansson and Wadsö for a commercial Thermometric TAM heat conduction batch microcalorimeter, the incident light from an external xenon lamp was divided by a beam splitter and directed to the two vessels of the differential system by light...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics