TITLE

Design considerations for an electrobalance microforce sensor

AUTHOR(S)
Peterson, I.R.
PUB. DATE
February 1997
SOURCE
Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1130
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Details the design of two microforce sensors using the electrobalance principle and commercially available galvanometer units. Derivation of a plausible form for the open-loop frequency response to be expected from optical detection; Application of the Nyquist criterion for stability of the feedback circuit.
ACCESSION #
4302322

 

Related Articles

  • Generalized hard x-ray detection model for microchannel plate detectors Shikhaliev, P.M. // Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3676 

    Develops a generalized hard x-ray detection model for microchannel plate (MCP) detectors. Analytical investigation and numerical calculation of the detection efficiency; Detection efficiency as a function of channel wall thickness, channel diameter, MCP thickness, lead content and quantum energy.

  • New sensor for measuring thermal conductivity in liquid metal by transient hot wire method. Nakamura, Shin; Hibiya, Taketoshi; Yamamoto, Fumio // Review of Scientific Instruments;Jun88, Vol. 59 Issue 6, p997 

    A new sensor has been developed for measuring thermal conductivity in liquid metal by transient hot wire method. A wire, which is formed in a thin alumina plate, was used for observing temperature rise of the wire, when a constant input power was applied to it. With this sensor, thermal...

  • Endoscopic fluorescence detector. Lenz, Peter // Review of Scientific Instruments;Jun88, Vol. 59 Issue 6, p930 

    This instrument, working in conjunction with standard clinical endoscopes, detects the fluorescence of hematoporphyrin derivative accumulated in tumors. At the same time, the operator receives a conventional image of the target and a signal indicating the intensity of fluorescence. Owing to the...

  • Vacuum ultraviolet and ultrasoft x-ray diode detectors for tokamak plasmas. Lee, Ping; Gernhardt, J.; Armentrout, C. J.; Snider, R. T. // Review of Scientific Instruments;Jun88, Vol. 59 Issue 6, p883 

    Ultrasoft x-ray diode (USXRD) arrays have been used on DIII-D and ASDEX to study plasma edge radiation, in the photon energy range from 10 eV to 10 keV. The detectors are extremely useful and versatile due to their simplicity and compactness. Furthermore, absolute quantum efficiencies (QE) of...

  • Application of a position-sensitive detector to atom probe microanalysis. Cerezo, A.; Godfrey, T. J.; Smith, G. D. W. // Review of Scientific Instruments;Jun88, Vol. 59 Issue 6, p862 

    A position-sensitive detector system based on a wedge-and-strip anode has been used to build a short flight-path atom probe which identifies both the chemical nature and position of single atoms field evaporated from the surface of a field-ion specimen. The detector also allows digitized...

  • A New Shadow-Ring Device for Measuring Diffuse Solar Radiation at the Surface. De Oliveira, Amauri P.; Machado, Antonio J.; Escobedo, Joao F. // Journal of Atmospheric & Oceanic Technology;May2002, Vol. 19 Issue 5, p698 

    Provides information on a study which described the performance of movable detector device (MDD), developed in the Laboratory of Solar Radiation at the State University of Sao Paulo, Brazil. Features of the shadow-ring device; Seasonal evolution of MDD correction factor; Effect of latitude on...

  • Sorting through solid-state sensors. Schneider, R.T. // Hydraulics & Pneumatics (1996);Oct98, Vol. 51 Issue 10, p83 

    Presents information on the array of inductive proximity and position sensors, with accuracy and reliability, that could be found in the 1990s. Details on optical sensors; Features of an inductive sensor; Type of conditions which proximity sensors are well suited for; Identification of the...

  • Infrared detectors. Levinstein, Henry // Physics Today;Nov77, Vol. 30 Issue 11, p23 

    Deals with developments in single-crystal infrared photon detector technology. Information on thermal and photon detectors; Parameters of infrared detection; Details on detectors with adjustable energy gaps.

  • Laser Rapier. Williams, David // Treasure Hunting;Nov2006, p67 

    The article evaluates Laser Rapier detector.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics