TITLE

NEW MATERIALS AND COMPONENTS

AUTHOR(S)
Farmer, Barry L.
PUB. DATE
September 1996
SOURCE
Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3382
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents scientific materials and components. Contraction actuators; Oil/water separators; Lenses.
ACCESSION #
4302131

 

Related Articles

  • Fragment Separator ACCULINNA-2. Krupko, S. A.; Fomichev, A. S.; Chudoba, V.; Daniel, A. V.; Golovkov, M. S.; Gorshkov, V. A.; Grigorenko, L. V.; Oganessian, Yu. Ts.; Sidorchuk, S. I.; Slepnev, R. S.; Stepantsov, S. V.; Tarasov, O. B.; Ter-Akopian, G. M.; Wolski, R.; Ershov, S. N.; Lukyanov, V. K.; Danilin, B. V.; Korsheninnikov, A. A.; Goldberg, V. Z.; Mukha, I. G. // AIP Conference Proceedings;4/30/2010, Vol. 1224 Issue 1, p516 

    Project of a new in-flight fragment separator is proposed as a part of the third generation DRIBs facilities in Dubna. As compared to the existing separator ACCULINNA, beam intensity should be increased by a factor 10–15, the beam quality improved and the RIB assortment should broaden...

  • A linear actuator with 3 Ã… closed-loop control resolution and 50 mm travel range (abstract). Shu, Deming; Han, Yufeng; Toellner, Thomas S.; Alp, Esen E. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1583 

    We have designed and constructed a novel linear actuator with 3 Ã… closed-loop control resolution and 50 mm travel range. Two major ultraprecision motion control techniques have been applied to this actuator: (i) a novel laser Doppler encoder system with multiple-reflection optics [D. Shu et...

  • Electrostatic ion guide using double cylindrical electrode for atmospheric pressure ionization... Takada, Yasuaki; Sakairi, Minoru; Ose, Yoichi // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2139 

    Describes an electrostatic ion focusing lens that consists of two-cylindrical electrodes positioned coaxially with each other. Formation of square openings in the inner electrode; Penetration of an electric field into the interior of the inner electrode through the openings when a potential is...

  • Electrostatic lens potentials with small relativistic spherical aberration. Kiss, L. // Review of Scientific Instruments;May89, Vol. 60 Issue 5, p907 

    We discuss a computerized systematic investigation to find axially symmetric electrostatic lens potentials with acceptable first-order properties and small spherical aberrations. The calculation of the spherical aberration is based on the direct solution of the relativistic trajectory equation...

  • Scaling up the colliding shock lens. Kuppen, M.; Michaelis, M.M.; Buccellato, R.; Lisi, N. // Review of Scientific Instruments;Oct95, Vol. 66 Issue 10, p5037 

    Discussed the characterization of the behavior of a new pulsed gas lens, the colliding shock lens. How input energy, electrical diameter, number of discharge electrodes and enclosing the discharges affect the optical aperture and focal length; Presentation of experimental results for three...

  • Improved measurement for volatile particles: Vapor-particle separator design and laboratory tests. Cheng, Meng-Dawn; Allman, Steve E. // Review of Scientific Instruments;Dec2011, Vol. 82 Issue 12, p125106 

    Sampling and measurement of volatile particles is a challenging task. It has been hampered by lack of a reliable technique capable of accurately capturing the phase-partition process of the pollutants without generating bias and artifacts in the data. The objective of this research is to design...

  • Simultaneous measurement of spatially separated forces using a dual-cantilever resonance-based touch sensor. Phan, Jack V.; Hocken, Robert; Smith, Stuart T.; Keanini, Russell G. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p318 

    A simple device for simultaneously measuring two spatially separated contact forces is described. The device uses a monolithic dual-cantilever touch sensor driven by a piezoelectric PZT actuator. A phase-locking method allows measurement of resonant frequency shifts at constant phase, based on...

  • A design of large current ion gun employing liquid metal ion source. Mori, Yuzo; Wang, Hui; Endo, Katsuyoshi; Yamauchi, Kazuto; Ide, Takashi // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1874 

    A lens system for a large current liquid metal ion source has been designed by a numerical computer simulation method. As a computed result, the lens system can focus an ion beam having an emission angle of 60° to a beam having a radius of 1.8 mm at 1 m from the ion source. Following the...

  • Chromatic aberration of three-cylinder electrostatic lenses. Olson, D.; Szilagyi, M. // Review of Scientific Instruments;Jun92, Vol. 63 Issue 6, p3339 

    Accurate calculations of the axial chromatic aberration coefficients of geometrically symmetric three-cylinder tripotential electrostatic lenses are presented for two different center electrode lengths. This is an extension of the first-order properties and the third-order spherical aberration...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics