TITLE

NEW MATERIALS AND COMPONENTS

AUTHOR(S)
Farmer, Barry L.
PUB. DATE
September 1996
SOURCE
Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3382
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents scientific materials and components. Contraction actuators; Oil/water separators; Lenses.
ACCESSION #
4302131

 

Related Articles

  • Fragment Separator ACCULINNA-2. Krupko, S. A.; Fomichev, A. S.; Chudoba, V.; Daniel, A. V.; Golovkov, M. S.; Gorshkov, V. A.; Grigorenko, L. V.; Oganessian, Yu. Ts.; Sidorchuk, S. I.; Slepnev, R. S.; Stepantsov, S. V.; Tarasov, O. B.; Ter-Akopian, G. M.; Wolski, R.; Ershov, S. N.; Lukyanov, V. K.; Danilin, B. V.; Korsheninnikov, A. A.; Goldberg, V. Z.; Mukha, I. G. // AIP Conference Proceedings;4/30/2010, Vol. 1224 Issue 1, p516 

    Project of a new in-flight fragment separator is proposed as a part of the third generation DRIBs facilities in Dubna. As compared to the existing separator ACCULINNA, beam intensity should be increased by a factor 10–15, the beam quality improved and the RIB assortment should broaden...

  • A linear actuator with 3 Ã… closed-loop control resolution and 50 mm travel range (abstract). Shu, Deming; Han, Yufeng; Toellner, Thomas S.; Alp, Esen E. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1583 

    We have designed and constructed a novel linear actuator with 3 Ã… closed-loop control resolution and 50 mm travel range. Two major ultraprecision motion control techniques have been applied to this actuator: (i) a novel laser Doppler encoder system with multiple-reflection optics [D. Shu et...

  • Electrostatic ion guide using double cylindrical electrode for atmospheric pressure ionization... Takada, Yasuaki; Sakairi, Minoru; Ose, Yoichi // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2139 

    Describes an electrostatic ion focusing lens that consists of two-cylindrical electrodes positioned coaxially with each other. Formation of square openings in the inner electrode; Penetration of an electric field into the interior of the inner electrode through the openings when a potential is...

  • Electrostatic lens potentials with small relativistic spherical aberration. Kiss, L. // Review of Scientific Instruments;May89, Vol. 60 Issue 5, p907 

    We discuss a computerized systematic investigation to find axially symmetric electrostatic lens potentials with acceptable first-order properties and small spherical aberrations. The calculation of the spherical aberration is based on the direct solution of the relativistic trajectory equation...

  • Scaling up the colliding shock lens. Kuppen, M.; Michaelis, M.M.; Buccellato, R.; Lisi, N. // Review of Scientific Instruments;Oct95, Vol. 66 Issue 10, p5037 

    Discussed the characterization of the behavior of a new pulsed gas lens, the colliding shock lens. How input energy, electrical diameter, number of discharge electrodes and enclosing the discharges affect the optical aperture and focal length; Presentation of experimental results for three...

  • Improved measurement for volatile particles: Vapor-particle separator design and laboratory tests. Cheng, Meng-Dawn; Allman, Steve E. // Review of Scientific Instruments;Dec2011, Vol. 82 Issue 12, p125106 

    Sampling and measurement of volatile particles is a challenging task. It has been hampered by lack of a reliable technique capable of accurately capturing the phase-partition process of the pollutants without generating bias and artifacts in the data. The objective of this research is to design...

  • Simultaneous measurement of spatially separated forces using a dual-cantilever resonance-based touch sensor. Phan, Jack V.; Hocken, Robert; Smith, Stuart T.; Keanini, Russell G. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p318 

    A simple device for simultaneously measuring two spatially separated contact forces is described. The device uses a monolithic dual-cantilever touch sensor driven by a piezoelectric PZT actuator. A phase-locking method allows measurement of resonant frequency shifts at constant phase, based on...

  • A design of large current ion gun employing liquid metal ion source. Mori, Yuzo; Wang, Hui; Endo, Katsuyoshi; Yamauchi, Kazuto; Ide, Takashi // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1874 

    A lens system for a large current liquid metal ion source has been designed by a numerical computer simulation method. As a computed result, the lens system can focus an ion beam having an emission angle of 60° to a beam having a radius of 1.8 mm at 1 m from the ion source. Following the...

  • Chromatic aberration of three-cylinder electrostatic lenses. Olson, D.; Szilagyi, M. // Review of Scientific Instruments;Jun92, Vol. 63 Issue 6, p3339 

    Accurate calculations of the axial chromatic aberration coefficients of geometrically symmetric three-cylinder tripotential electrostatic lenses are presented for two different center electrode lengths. This is an extension of the first-order properties and the third-order spherical aberration...