TITLE

A photodiode for the measurement of soft x-ray radiation from plasma

AUTHOR(S)
Qingjun Xiao; Navratil, Gerald
PUB. DATE
September 1996
SOURCE
Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3334
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Reports on the use of photodiodes as detectors on the high beta tokamak-extended pulse tokamak for soft x-ray radiation measurement. Sawteeth instabilities and magnetohydrodynamic oscillations found in the signals from the photodiodes.
ACCESSION #
4302129

 

Related Articles

  • Soft x-ray tomography diagnostic for the Alcator C tokamak. Camacho, J. F.; Granetz, R. S. // Review of Scientific Instruments;Mar86, Vol. 57 Issue 3, p417 

    A soft x-ray tomography diagnostic has been built and operated on the Alcator C tokamak with the use of an 80-channel array of detectors. The detector system consists of miniature PIN photodiodes which are located around the periphery of the plasma at one toroidal location (top and bottom ports)...

  • Design and initial operation of multichord soft x-ray detection arrays on the STOR-M tokamak. Xiao, C.; Niu, T.; Morelli, J. E.; Paz-Soldan, C.; Dreval, M.; Elgriw, S.; Pant, A.; Rohraff, D.; Trembach, D.; Hirose, A. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E926 

    Two miniature pinhole camera arrays for spatially and temporally resolved measurements of soft x-ray emission have been designed and installed on the STOR-M tokamak. Each array consists of a photodiode array, with one array viewing vertically and one viewing horizontally through a plasma cross...

  • Introducing minimum Fisher regularisation tomography to AXUV and soft x-ray diagnostic systems of the COMPASS tokamak. Mlynar, J.; Imrisek, M.; Weinzettl, V.; Odstrcil, M.; Havlicek, J.; Janky, F.; Alper, B.; Murari, A.; JET-EFDA Contributors // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10E531 

    The contribution focuses on plasma tomography via the minimum Fisher regularisation (MFR) algorithm applied on data from the recently commissioned tomographic diagnostics on the COMPASS tokamak. The MFR expertise is based on previous applications at Joint European Torus (JET), as exemplified in...

  • Duplex multiwire proportional x-ray detector for multichord time-resolved soft x-ray and electron temperature measurements on T-10 tokamak. Sushkov, A. V.; Andreev, V. F.; Kravtsov, D. E. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E319 

    Compact 64-channel multiwire proportional chamber is successfully used on T-10 and TCV tokamaks as a continuous-current soft x-ray detectors. The duplex multiwire proportional x-ray detector is a new generation of these detectors. It has been designed for simultaneous multichord measurement of...

  • Measurement of the temporal and spectral characteristics of silicon p—i—n photodiodes in the soft x-ray range. Golubev, A. V.; Pivinskiı, E. G.; Akulinichev, V. V.; Sorokin, A. A.; Bobashev, S. V. // Technical Physics;May99, Vol. 44 Issue 5, p553 

    A procedure is briefly described for investigating the temporal and spectral characteristics of a soft x-ray detector in the range of photon energies from a few tenths of an electron-volt to more than a thousand electron-volts. The measured characteristics (signal rise time, time resolution, and...

  • Relative calibration of photodiodes in the soft-x-ray spectral range. Anton, M.; Dutch, M.J.; Weisen, H. // Review of Scientific Instruments;Jul1995, Vol. 66 Issue 7, p3762 

    Presents a method of obtaining a relative calibration of Si photodiodes for the spectral range of soft x-rays. Adoption of a simple mathematical model of the p-n diode; Calculation of photodiode efficiencies; Use of the method to obtain precise characterization of the diode response and...

  • The JET soft x-ray diagnostic systems Alper, B.; Dillon, S.; Edwards, A. W.; Gill, R. D.; Robins, R.; Wilson, D. J. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p778 

    Describes the construction of a multicamera soft x-ray (SXR) detector system for the pumped divertor phase of the Joint European Torus tokamak to provide improved spatial and temporal resolution. Features of the SXR camera assemblies; Detector performance tests; Operational experience and...

  • Soft x-ray imaging using Polaroid Land films. Wong, C. S.; Choi, P.; Deeney, C. // Review of Scientific Instruments;Feb1988, Vol. 59 Issue 2, p391 

    It is demonstrated in this note that optical Polaroid Land films can be used as a convenient detector in the soft x-ray region. The performance of Polaroid 667 film has been found to be comparable to that of the Kodak direct exposure film (DEF) for soft x-ray pinhole imaging. By a suitable...

  • Measurements of soft X-ray lasers wavefront. Pape, S. Le; Zeitoun, Ph.; Idir, M.; Dhez, P.; Ros, D.; Carillon, A.; Rocca, J. J.; Francois, M.; Sebban, S. // AIP Conference Proceedings;2002, Vol. 641 Issue 1, p602 

    A Shack-Hartmann wavefront sensor has been developed at the Laboratoire de l'Interaction du Rayonnement X avec la Matière, for a characterization of soft x-ray laser beam. A mapping of the wave-vectors pointing of laser-pumped soft x-ray laser (Optical Field induced and 100 ps laser pumped...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.