TITLE

Electric-field measurement near a ring antenna by a new field sensor using piezoelectric resonance

AUTHOR(S)
Daehaeng Lee; Soonchil Lee
PUB. DATE
September 1996
SOURCE
Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3320
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Investigates the electric-field measurement near a ring antenna by a new field sensor using piezoelectric resonance. Evaluations of dependence of the picked up resonance signal on the amplitude and direction of external electric field.
ACCESSION #
4302126

 

Related Articles

  • Design of Electric Field Sensors for Measurement of Electromagnetic Pulse. Hui ZHANG; Yinghui ZHOU; Lihua SHI; Rupo MA; Zhengyu HUANG // Sensors & Transducers (1726-5479);Jan2014, Vol. 162 Issue 1, p131 

    In this paper, a D-dot electric field sensor and a fiber-optic transmission electric field sensor are developed for measurement of electromagnetic pulse. The D-dot sensor is a differential model sensor without source and has a simple structure. The fiber-optic transmission sensor is in the type...

  • A nondisturbing electric-field sensor using piezoelectric and converse piezoelectric resonances. Lee, Yongkwan; Kim, Ilryong; Lee, Soochil // Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4427 

    Presents an electric-field sensor using both piezoelectric and converse piezoelectric resonances. Minimization of field disturbance; Distinguishing feature of the probe; Demonstration of the field sensing capability of the probe; Dominance of the capacitive field in an empty solenoid.

  • Scanning Device for Sampling the Spatial Distribution of the E-field. Blas, Juan; Bahillo, Alfonso; Mazuelas, Santiago; Bullido, David; Fernández, Patricia; Lorenzo, Ruben M.; Abril, Evaristo J. // Proceedings of World Academy of Science: Engineering & Technolog;2007, Vol. 24, p199 

    This paper presents a low cost automatic system for sampling the electric field in a limited area. The scanning area is a flat surface parallel to the ground at a selected height. We discuss in detail the hardware, software and all the arrangements involved in the system operation. In order to...

  • Expression of picogram sensitive bending modes in piezoelectric cantilever sensors with nonuniform electric fields generated by asymmetric electrodes. Johnson, Blake N.; Mutharasan, Raj // Review of Scientific Instruments;Dec2010, Vol. 81 Issue 12, p125108 

    Single-layer uniform cross-sectioned piezoelectric macro-cantilevers fabricated with an asymmetric electrode configuration enabled electrical measurement of picogram-sensitive resonant bending modes in liquids. Bending modes were otherwise not electrically measurable without excitation by a...

  • Electromechanical behavior of BaTiO[sub 3] from first principles. Garci´a, Alberto; Vanderbilt, David // Applied Physics Letters;6/8/1998, Vol. 72 Issue 23, p2981 

    Using an effective Hamiltonian parametrized from first principles, Monte Carlo simulations are performed in order to study the piezoelectric response of BaTiO[sub 3] in the ferroelectric tetragonal phase as a function of temperature. The effect of an electric field on the phase behavior is also...

  • Electric field accompanying the motion of a body in air. Bivin, Yu. // Technical Physics;Oct2011, Vol. 56 Issue 10, p1527 

    Air flow electrization induced by the motion of bodies made of different materials is studied experimentally by detecting a potential appearing at an annular antenna through which the body passes. It is found that the motion of the body is accompanied by the motion of two unlike charges. The...

  • Note: Piezoelectric strain voltage sensing at ultra-low frequencies. Laskovski, A.; Moheimani, S. O. R.; Yuce, M. R. // Review of Scientific Instruments;Aug2011, Vol. 82 Issue 8, p086113 

    Piezoelectric sensors have emerged as a versatile tool for measurement of various quantities such as pressure, acceleration, strain, or force across many industrial applications. When mechanically strained, electric charges are produced inside a piezoelectric transducer. These charges result in...

  • IZLOŽENOST LJUDI ZRAÄŒENJU ANTENSKIH SUSTAVA BAZNIH POSTAJA - DOZIMETRIJA UPADNOG POLJA. Poljak, D. // Sigurnost;2012, Vol. 54 Issue 2, p173 

    The paper deals with the theoretical and experimental incident field dosimetry for GSM and UMTS base station antennas regarding human exposure to these systems. Calculation and measurement of the field radiated by GSM and UMTS base stations is carried out for the worst case scenario of exposure....

  • Analytical, Simulation and Measurement Studies of a Dual-Band Open-Sleeve Curved Meander Line Antenna on a Flexible Substrate. Georget, Elodie; Abdeddaim, Redha; Sabouroux, Pierre // Progress in Electromagnetics Research;Feb2014, Vol. 145, p49 

    An innovative antenna on flexible substrate with two resonators is presented. The antenna is composed of a metallic wire sewn on the substrate. Two dipolar modes in far field are radiated. To understand the interaction of the resonators with the principal antenna, studies with and without the...

Share

Read the Article

Courtesy of NEW JERSEY STATE LIBRARY

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics