TITLE

A submillimeter polychromator for plasma spectroscopy

AUTHOR(S)
Tudisco, O.; Berton, F.; Buratti, P.; Grilli, E.; Mantovani, S.
PUB. DATE
September 1996
SOURCE
Review of Scientific Instruments;Sep96, Vol. 67 Issue 9, p3108
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a 12-channel grating polychromator for the measurement of electron cyclotron emission on the Frascati tokamak upgrade (FTU). Remote exchanging of three gratings; Optimization of sets of low-pass filters for each grating; Performance of the exchange of gratings and filters.
ACCESSION #
4302097

 

Related Articles

  • Measurement of lower-hybrid-driven current profile by Abel inversion of electron-cyclotron wave transmission spectra. Fidone, I.; Giruzzi, G.; Caron, X.; Meyer, R. L. // Physics of Fluids B: Plasma Physics;Oct91, Vol. 3 Issue 10, p2719 

    A method for measuring the radial profile of the lower-hybrid-driven current in a low-density tokamak plasma using electron-cyclotron wave attenuation is discussed. This diagnostic scheme is reminiscent of the transmission interferometry approach, commonly used in tokamaks to measure the plasma...

  • Electron density measurements from cutoff of electron cyclotron emission in the DIII-D tokamak. Lohr, John // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1608 

    Cutoff of microwave emission at the second harmonic of the electron cyclotron frequency has been used to infer the local electron density profile in the DIII-D tokamak. Modeling the density profile during the uncontrolled density increase associated with the transition to H-mode operation...

  • Measurement of current drive profile using electron cyclotron wave attenuation near the O-mode cutoff. Fidone, I.; Meyer, R. L.; Caron, X. // Physics of Fluids B: Plasma Physics;Jan92, Vol. 4 Issue 1, p145 

    A method for determining the radial profile of the lower-hybrid current drive in tokamaks using electron cyclotron attenuation of the O mode for frequencies ω near the cutoff frequency is discussed. The basic idea is that, for a given wave frequency, the cutoff plays the role of a spatial...

  • High resolution electron cyclotron emission temperature profile and fluctuation diagnostic for... Heard, J.W.; Watts, C.; Gandy, R.F.; Phillips, P.E.; Cima, G.; Chatterjee, R.; Blair, A.; Hubbard, A.; Domier, C.W.; Luhmann Jr., N.C. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p1011 

    Describes the installation a second harmonic heterodyne electron cyclotron emission system with high spatial resolution and a large number of channels for dense profile coverage on Alcator C-Mod tokamak. Generation of detailed radial electron temperature profiles and core temperature...

  • An inexpensive instrument to detect radio-frequency leakage from transmission lines at millimeter... Simonetto, A.; Muzzini, V.; Bruschi, A.; Cirant, S.; Granucci, G.; Sozzi, C. // Review of Scientific Instruments;Dec1996, Vol. 67 Issue 12, p4333 

    Discusses the use of arrays of thermophile detectors arranged on flat panels to measure stray radiation from high-power transmission lines in a FTU tokamak electron cyclotron resonance heating experiment. Instruments' insensitivity to polarization and to the direction of propagation;...

  • Tokamak plasmas with dominant electron cyclotron heating; evidence for electron thermal transport... de Baar, M. R.; Beurskens, M. N. A.; Hogeweij, G.M.D.; Cardozo, N.J. Lopes // Physics of Plasmas;Dec99, Vol. 6 Issue 12, p4645 

    Focuses on the Rijnhuizen Tokamak Project (RTP), where experiments were carried out with Electron Cyclotron Heating (ECH) at four to seven times the Ohmic power. Deposition width; Transitions that occur for a displacement of the deposition; How each transition is due to the loss of a transport...

  • Electron cyclotron emission diagnostics on the large helical device. Nagayama, Y.; Kawahata, K.; England, A.; Ito, Y.; Bretz, N.; McCarthy, M.; Taylor, G.; Doane, J.; Ikezi, H.; Edlington, T.; Thomas, J. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p1021 

    Describes the electron cyclotron emission diagnostic system installed on the large helical device (LHD). Instruments of the system; Utilization of a corrugated waveguide system; Development of large collection optics and notch filters at the frequency of the LHD electron cyclotron heating.

  • Effect of secondary electron emission on sheath potential in an electron cyclotron resonance plasma. Yao, X.Z.; Jiang, D.Y. // Journal of Applied Physics;3/1/1997, Vol. 81 Issue 5, p2119 

    Studies the effect of secondary electron emission on sheath potential in an electron cyclotron resonance plasma. Difference between plasma potential and the floating potential; Need for thermionic electron emission; Total energy transmission factors.

  • Electron cyclotron emission diagnostics on KSTAR tokamak. Jeong, S. H.; Lee, K. D.; Kogi, Y.; Kawahata, K.; Nagayama, Y.; Mase, A.; Kwon, M. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D922 

    A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne...