TITLE

A small, insertable oven for boronization

AUTHOR(S)
Brouchous, D.A.; Diebold, D.A.; Doczy, M.L.
PUB. DATE
April 1996
SOURCE
Review of Scientific Instruments;Apr96, Vol. 67 Issue 4, p1529
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents an insertable oven for benchmarking the boronizing characteristics of solid compounds such decaborane and carborane. Assembly and installation of the oven; Film deposited by heating carborane into the vapor state; Overall plasma performance.
ACCESSION #
4302043

 

Related Articles

  • Critical field index for passive coil stabilization of the spheromak shift instability. Goldenbaum, G. C.; Hess, R. A.; Shaw, R. S. // Review of Scientific Instruments;Dec1986, Vol. 57 Issue 12, p2961 

    The physics of a shifting spheromak plasma inside a passive stabilization coil is examined. Criteria for the design of these coils are derived for various spheromak current distributions. For realistic coils and force-free plasmas a critical field index is derived, above which the coils are...

  • Reentrant cavity as a low-power plasma source. Brown, M. R.; Sheridan, T. E.; Hayes, M. A. // Review of Scientific Instruments;Dec1986, Vol. 57 Issue 12, p2957 

    A low-power source of plasma employing ECRH microwave breakdown in a reentrant cavity is described. The cavity has the following features: its dimensions can be made much smaller than its resonant wavelength, cavity Q values of several hundred are not difficult to achieve, and the vacuum rf...

  • On the possibility of neutron spectrometry for determination of fuel ion densities in DT plasmas. Källne, J.; Batistoni, P.; Gorini, G. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2871 

    The fuel density (given by n[sub d]+n[sub t] and n[sub d]/n[sub t]) is one of the important parameters to determine and control in burning DT plasmas. Here, we propose that n[sub d] and n[sub t] be deduced from data on the dd and dt neutron energy distributions to be recorded with a neutron...

  • A fully three-dimensional-movable, 10-m-long, remotely controllable probe drive for a plasma discharge device. Pfister, H.; Gekelman, W.; Bamber, J.; Leneman, D.; Lucky, Z. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2884 

    A unique, fully three-dimensional-movable, 10-m-long, remotely controllable probe drive, internal to a high vacuum system, is described. Details of its design and constructional considerations take into account the hostile environment of a magnetized plasma (p = 8 × 10[sup -8] Torr, T = 250...

  • A three-frame Mach–Zehnder interferometer for measuring dense magnetized plasmas. Wang, Xinxin; Zou, Xiaobing; Liu, Zhen; Han, Min; Luo, Chengmu; Ma, Ruili // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1328 

    A three-frame Mach-Zehnder interferometer (TFMZI) was developed for taking three pictures of the imploding plasma produced by one shot of fast pulsed discharge. TFMZI consists of a YAG laser, a beam splitter, and a Mach-Zehnder interferometer. By passing through the beam splitter the laser beam...

  • Acceleration characteristics of spherical and nonspherical pellets by the LHD impurity pellet injector. Nozato, Hideaki; Morita, Shigeru; Goto, Motoshi; Ejiri, Akira; Takase, Yuichi // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p2032 

    An impurity pellet injector with three differential pumping systems has been developed to study the particle/impurity transport in combination with bremsstrahlung profile measurement in the Large Helical Device (LHD) plasma. For this purpose three different shaped pellets are tested; sphere,...

  • Analysis of high current X-pinch structure in keV and sub-keV regions. Fedin, D. A.; Kantsyrev, V. L.; Shlyaptseva, A. S.; Hansen, S. B.; Ouart, N. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1939 

    The complex measurements with spectral, temporal, and spatial resolution are very important in studies of properties of radiation from hot dense plasmas (T[sub e] up to 1.5 keV, N[sub e] up to 10[sup 22] cm[sup -3]) generated by a pulse-powered Z-pinch machine with I[sub max]∼0.9-1.0 MA and...

  • Diagnosing the velocity-space separatrix of trapped particle modes. Kabantsev, A. A.; Driscoll, C. F. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1925 

    Trapped particle modes in pure electron plasmas are similar to modes in neutral plasmas and exhibit damping due to velocity diffusion across the separatrix between trapped and untrapped particles, as commonly occurs in neutral plasmas. Applied rf voltages cause resonant perturbation of particle...

  • Gamma-diagnostics of alpha-particles in [sup 4]He and D–T plasmas. Kiptily, V. G.; Popovichev, S.; Sharapov, S. E.; Bertalot, L.; Cecil, F. E.; Conroy, S.; Mantsinen, M. J. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1753 

    This article reports on γ-ray diagnosis of ICRF-accelerated [sup 4]He ions and fusion α particles used in the JET tokamak. This diagnostic based on the analysis of γ rays emitted in nuclear reaction [sup 9]Be(α, n γ) [sup 12]C. The results of the first observation of the 4.44-MeV...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics