TITLE

Diffractive grating structure for coherent light source production

AUTHOR(S)
Lee, S. Y.; Jing, Y. C.; Luo, T.; Pang, X.; Wang, X.; Ng, K. Y.
PUB. DATE
June 2009
SOURCE
Review of Scientific Instruments;Jun2009, Vol. 80 Issue 6, p066102
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A diffractive structure of cavities is designed to produce resonances at very high frequencies. This type of cavity structure may be useful for producing controllable coherent synchrotron radiation by microbunching the particle beam.
ACCESSION #
42961892

 

Related Articles

  • Status of the SAGA Light Source. Kaneyasu, T.; Takabayashi, Y.; Iwasaki, Y.; Koda, S. // AIP Conference Proceedings;6/24/2010, Vol. 1234 Issue 1, p583 

    The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006....

  • Observation of Multi-bunch Interference with Coherent Synchrotron Radiation. Billinghurst, B. E.; May, T.; Bergstrom, J.; DeJong, M.; Dallin, L. // AIP Conference Proceedings;2/3/2010, Vol. 1214 Issue 1, p10 

    The observation of Multi-bunch interference with coherent synchrotron radiation at the Canadian Light Source is discussed along with the possibility that some of the spectral features are driven by the radiation impedance of the vacuum chamber.

  • Development of an Abort Gap Monitor for High-Energy Proton Rings. Beche, J.-F.; Byrd, J.; De Santis, S.; Denes, P.; Placidi, M.; Turner, W.; Zolotorev, M. // AIP Conference Proceedings;2004, Vol. 732 Issue 1, p105 

    The fill pattern in proton synchrotrons usually features an empty gap, longer than the abort kicker raise time, for machine protection. This gap is referred to as the “abort gap,” and any particles, which may accumulate in it due to injection errors and diffusion between RF buckets,...

  • Center for the Advancement of Natural Discoveries using light emission: A new project for 3 GeV intermediate energy light source in the Republic of Armenia. Tsakanov, V.; Avagyan, V.; Ayvazyan, V.; Amatuni, G.; Grigoryan, B.; Ivanian, M.; Laziev, E.; Martirosyan, Y.; Mikaelyan, R.; Tatikian, S.; Vardanyan, A. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1411 

    We are planning to construct a 3 GeV synchrotron light source in the Republic of Armenia called Center for the Advancement of Natural Discoveries using light emission—CANDLE. The purpose of the machine is to produce high flux and high brightness photon beams from bends and insertion...

  • Status of the LCLS x-ray FEL program (invited). Arthur, John // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1393 

    The Linac Coherent Light Source (LCLS) program involves a collaboration of several U.S. National Laboratories and universities with the goal of designing and building the first fourth-generation hard x-ray source, an x-ray free-electron laser (FEL). This FEL will utilize extremely short,...

  • Design and Performance of Undulator Beamline (BL7U) for in-situ Observation of Synchrotron Radiation Stimulated Etching by STM. Nonogaki, Y.; Katoh, M.; Shigemasa, E.; Matsushita, K.; Suzui, M.; Urisu, T.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p368 

    An undulator beamline (BL7U) equipped with an ultra-high vacuum STM system is constructed at the UVSOR facility to investigate excitation energy dependence in synchrotron radiation (SR) stimulated etching. The SR beam is focused using two cylindrical mirrors on the sample surface just under the...

  • Synchrotron Radiation Profile Monitor for the HERA Positron Beam. Kube, G.; Fischer, R.; Wittenburg, K. // AIP Conference Proceedings;2004, Vol. 732 Issue 1, p350 

    For the measurement of the positron beam emittance at the e-p storage ring HERA at DESY a monitor is used which is based on the direct imaging of visible synchrotron radiation from a bending magnet. While the resolution of profile measurements by synchrotron radiation is already strictly limited...

  • The infrared synchrotron radiation beamline at the third generation light source ELETTRA. Nucara, Alessandro; Lupi, Stefano; Calvani, Paolo // Review of Scientific Instruments;Sep2003, Vol. 74 Issue 9, p3934 

    The synchrotron radiation emitted in the infrared range from a bending magnet of the third generation storage ring ELETTRA is studied in detail by simulation techniques. Edge effects are taken into account. Preliminary experimental checks on an existing port for beam diagnostics are reported....

  • Beam Stability: Raytracing Requirements and Implementations. Green, Michael A.; Bissen, Mark J.; Hallin, Emil L.; Pedley, Robert T.; Severson, Mary C.; Stott, John P.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p601 

    Stability to-the-user fundamentally starts with present needs and future goals from the user community conveyed to facility staff in terms of user observables into the sample chamber. These are then projected onto the requirements for both the beamlines and the sources. In turn, specifications...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library