TITLE

A high sensitivity time-resolved microfluorimeter for real-time cell biology

AUTHOR(S)
Martin-Fernandez, M.L.; Tobin, M.J.; Clarke, D.T.; Gregory, C.M.; Jones, G.R.
PUB. DATE
October 1996
SOURCE
Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3716
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes an instrument based on the novel combination of synchrotron radiation, a high sensitivity time-resolved microfluorimeter and a multiframe single photon counting data acquisition system. Design of the instrument to measure kinetic events in live cells using fluorescence resonance energy transfer; Ability to rapidly collect multiple consecutive decay profiles.
ACCESSION #
4295529

 

Related Articles

  • Present status of the SORTEC SR Facility. Atoda, N.; Awaji, N.; Kodaira, M.; Kishimoto, T.; Nishino, J.; Koga, K.; Maejima, Y.; Higashigawa, I.; Yanagida, K. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1611 

    The status and performance of the SORTEC SR facility is described. Emphasis is placed on the reliable operation and the high performance of the SR source and the status of major systems for x-ray lithography.

  • Infrared synchrotron radiation instrumentation and applications. Williams, Gwyn P. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1535 

    Infrared synchrotron radiation (IRSR) in the wavelength range from 1 μm to ∼1 cm has now been used quite extensively both in Japan at UVSOR, Okasaki and in the United States at the NSLS, Brookhaven, following an earlier program at the first infrared beamline at Daresbury in England....

  • High-temperature diffraction gratings for synchrotron radiation. Kita, Toshiaki; Harada, Tatsuo; Maezawa, Hideki; Muramatsu, Yasuji; Namba, Hidetoshi // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1424 

    SiC-based mechanically ruled master gratings and replicas are developed for synchrotron radiation instruments. An SiC-based gold replica grating without any thermal deformation due to active cooling is used in a high-photon-flux-soft x-ray monochromator that is installed in a bending magnet...

  • Time-resolved experiments in the frequency domain using synchrotron radiation (invited). De Stasio, Gelsomina; Giusti, A. M.; Parasassi, T.; Ravagnan, G.; Sapora, O. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1393 

    PLASTIQUE is the only synchrotron radiation beam line in the world that performs timeresolved fluorescence experiments in frequency domain. These experiments are extremely valuable sources of information on the structure and the dynamics of molecules. This technique measures fluorescence...

  • A novel crystal bender for x-ray synchrotron radiation monochromators. Zaeper, Ralf; Richwin, Matthias; Lu¨tzenkirchen-Hecht, Dirk; Frahm, Ronald // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1564 

    A new bending mechanism for an indirectly water cooled monochromator crystal has been developed. The main design goals were a lightweight construction, ease of manufacture, and control. The construction consists of a U-shaped first Si(111) crystal, which can be bent by compressed air to...

  • Stabilization and calibration of x-ray wavelengths for anomalous diffraction measurements using... Evans, G.; Pettifer, R.F. // Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3428 

    Discusses the stabilization and calibration of x-ray wavelengths for anomalous diffraction measurements using synchrotron radiation. Description of the calibration apparatus; Measuring the energy stability of a monochromatic x-ray beam; Measurement of the energy resolution of x-ray beam.

  • Noise characteristics of U. S. synchrotron radiation sources. Powers, L. // Review of Scientific Instruments;Dec1986, Vol. 57 Issue 12, p3024 

    Noise characteristics of the U. S. x-ray synchrotron sources are compared in the 0-2.5-kHz region. In general, little difference is found in the characteristic frequencies of the noise on focused and unfocused beamlines of a particular source, but the magnitude and white-noise levels differ. The...

  • DAPS-A new facility proposed for synchrotron radiation research in the UK. Padmore, H. A.; Poole, M. W.; Munro, I. H. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1599 

    The design parameters for a unique third generation synchrotron radiation source (DAPS) optimized to provide peak brillance in the range 5-100 eV for high flux, high spectroscopic resolution, imaging and polarization studies in the VUV-SXR regions.

  • Report of the satellite workshop on synchrotron radiation instrumentation for x-ray absorption spectroscopy. Greaves, G. N. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1625 

    Report of a workshop on synchrotron radiation instrumentation for x-ray absorption spectroscopy, a satellite meeting of the 4th International Conference on Synchrotron Radiation Instrumentation, will be presented. The workshop comprised presentations and discussions in the principal areas of...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics