A single-sweep, nanosecond time resolution laser temperature-jump apparatus

AUTHOR(S)
Ballew, R.M.; Sabelko, J.; Reiner, C.; Gruebele, M.
PUB. DATE
October 1996
SOURCE
Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3694
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a fast temperature-jump apparatus capable of acquiring kinetic relaxation transients via real-time fluorescence detection over a time interval from nanoseconds to milliseconds in a single sweep. Raman generation and temperature jump; Probe generation and fluorescence detection; Fluorescence analysis and determination of instrument `dead time'.
ACCESSION #
4295526

 

Related Articles

  • Improved double fluorescence detector for x-ray absorption spectroscopy. Heald, S. M. // Review of Scientific Instruments;Apr88, Vol. 59 Issue 4, p650 

    An improved double fluorescence detector for x-ray absorption spectroscopy is described and compared to a standard filter-slit detector.

  • Marketplace.  // LC-GC Asia Pacific;Mar2005, Vol. 8 Issue 1, p60 

    Presents several laboratory instruments and apparatus. Model 530 HPLC fluorescence detector; MassPREP on-line desalting cartridges from Waters; Agilent's 32-bit version of its ChemStation analytical laboratory software.

  • Microcantilever charged-particle flux detector. Stephan, A. C.; Gaulden, T.; Brown, A.-D.; Smith, M.; Miller, L. F.; Thundat, T. // Review of Scientific Instruments;Jan2002, Vol. 73 Issue 1, p36 

    A micromechanical sensor for charged-particle flux detection utilizing the extreme force sensitivity of microcantilevers is demonstrated with alpha particles. The latter create a charge buildup on an electrically isolated collection plate, a metallic sphere. The cantilever detector measures the...

  • Shape of β spectrum obtained with thin detectors. Ouseph, P. J.; Davis, C. L.; O’Bryan, M. Ray // Review of Scientific Instruments;May89, Vol. 60 Issue 5, p962 

    The β spectrum of Tl obtained using a 200-μm detector is distorted with a prominent peak centered around 97 keV. The features of this spectrum can be reproduced by a Monte Carlo procedure. The minimum ionizing nature of the electrons with energy higher than about 300 keV is responsible for...

  • Calibration of a Mott detector using circularly polarized impact radiation from helium. Uhrig, M.; Beck, A.; Goeke, J.; Eschen, F.; Sohn, M.; Hanne, G. F.; Jost, K.; Kessler, J. // Review of Scientific Instruments;May89, Vol. 60 Issue 5, p872 

    The conventional methods of determining the analyzing power of a Mott detector for electron-polarization measurement are not very accurate. That is why alternative methods have recently been discussed. The present paper shows how a Mott detector can be calibrated with an uncertainty of ±1%...

  • Continuous level sensors for cryogenic liquids using high-Tc superconductors. Siegmann, St.; Frey, T.; Ramseyer, J. P.; Güntherodt, H.-J. // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1946 

    We have developed a new device using high-temperature superconducting sensors for the continuous detection and control of the level of cryogenic liquids with boiling temperatures of up to 90 K. The sensors contain material of La-(Ba,Sr)-Cu or Y-Ba-Cu oxides with superconducting transition...

  • Charge-coupled device image detector for Schmidt telescopes. Natali, Giuliano; Pedichini, Fernando // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1839 

    The application of a charge-coupled device sensor at the focal plane of a Schmidt telescope is described. The device installed on the 60/90/180 cm Schmidt telescope at Campo Imperatore Astrophysical Observatory has a field of view of 17×25 arcmin. A special LN2 cooling system was installed...

  • A small electron cyclotron resonant plasma-based neutral-flux ionizer. Cain, B. L.; Ruzic, D. N. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3473 

    The design and operation of a neutral-hydrogen flux detection system is described. The central feature of the detector is an inductively driven electron cyclotron resonance heated (ECRH) discharge, which functions as the neutral-flux ionizer. The prominent features of the ionizer are its small...

  • Determination of depletion width of surface barrier detectors. Davis, C. L.; Ouseph, P. J.; O’Bryan, M. Ray // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3452 

    A simple experimental method to determine the depletion width of a surface barrier detector is discussed. An electron spectrum of Bi207 taken with a detector having depletion width less than the range of the electrons shows an additional peak. The position of the extra peak enables us to...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics