TITLE

Characteristics of an x-ray excited current detected with a scanning tunneling microscope tip

AUTHOR(S)
Tsuji, Kouichi; Hirokawa, Kichinosuke
PUB. DATE
October 1996
SOURCE
Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3573
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses characteristics of an x-ray excited current detected with a scanning tunneling microscope (STM) tip. STM apparatus under x-ray irradiation; Effect of the gas pressure and of the bias voltage; Effect of the x-ray intensity; Dependence of the tip current on the film thickness.
ACCESSION #
4295500

 

Related Articles

  • Two-dimensional, remote micropositioner for a scanning tunneling microscope. Mamin, H. Jonathon; Abraham, David W.; Ganz, Eric; Clarke, John // Review of Scientific Instruments;Nov85, Vol. 56 Issue 11, p2168 

    A simple walker is described that is suitable as the coarse positioner in a scanning tunneling microscope. The walker is fabricated from a single piece of piezoelectric ceramic and has feet coated with thin metal and insulating films. The walker can move in either of two orthogonal, horizontal...

  • Low-temperature ultrahigh-vacuum scanning tunneling microscope. Lang, C. A.; Dovek, M. M.; Quate, C. F. // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3109 

    We describe a multipurpose scanning tunneling microscope designed to operate in ultrahigh vacuum as well as in air, over a range extending from room temperature to liquid-nitrogen temperatures. It is a single-tube scanner design with a differential flexing approach mechanism mounted on a...

  • A new ultra-high vacuum scanning tunneling microscope design for surface science studies. Poirier, G. E.; White, J. M. // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3113 

    We have constructed a new scanning tunneling microscope (STM) designed especially for surface science studies. The novel feature of this design is a sample holder that can be backed away from the STM and then rotated about the central axis of a typically configured UHV chamber. This integrated...

  • Preparation and characterization of STM tips for electrochemical studies. Nagahara, L. A.; Thundat, T.; Lindsay, S. M. // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3128 

    We report on a fabrication technique for scanning tunneling microscopy (STM) tips for in situ electrochemical investigations. Unwanted Faradaic currents were minimized by insulating the STM tips with Apiezon wax. Cyclic voltammetry showed Apiezon wax to be inert in various electrolytes.

  • A scanning tunneling microscope with a wide sampling range. Hipps, K. W.; Fried, Glenn; Fried, Dale // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1869 

    Construction of a simple scanning tunneling microscope (STM) is described. This STM is suitable for atmospheric, controlled atmosphere, and high vacuum (but not UHV) work. This STM is especially well suited for determining surface topography on the 0.1 nm scale when images must be obtained over...

  • The Surrey STM: Construction, development, and evaluation of a scanning tunneling microscope. Hammiche, A.; Wei, Yu; Wilson, I. H.; Webb, R. P. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p3010 

    A scanning tunneling microscope has been built together with the necessary controlling electronics. Currently this is used at atmospheric pressure but is capable of use under vacuum with minor modifications. Trials of the system, and subsequent adjustments, have taken place using highly oriented...

  • Direct measurement instrument for lattice spacing on regular crystalline surfaces using a scanning tunneling microscope and laser interferometry. Rerkkumsup, Pongpun; Aketagawa, Masato; Takada, Koji; Watanabe, Tomonori; Sadakata, Shin // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1205 

    An instrument for direct measurement of the lattice spacing on regular crystalline surfaces, which incorporates a scanning tunneling microscope (STM) and a phase modulation homodyne interferometer (PMHI), was developed. Our aim was to verify the applicability of the length measurement method in...

  • A very low current scanning tunneling microscope. Dunlap, David; Smith, Steve; Bustamante, Carlos; Tamayo, Javier; Garcia, Ricardo // Review of Scientific Instruments;Oct95, Vol. 66 Issue 10, p4876 

    Presents a very low current scanning tunneling microscope (STM). Study of poor conducting materials as biological molecules; Operation of the STM; Illustration of the advantages of using very low currents.

  • A miniaturized scanning tunneling microscope with large operation range. Kleindiek, S.; Herrmann, K. H. // Review of Scientific Instruments;Mar93, Vol. 64 Issue 3, p692 

    A small sized (<1 cm3) and low mass (2.5 g) scanning tunneling microscope (STM) with automatized large range tip approach is introduced. By concentric arrangement of two piezotubes a temperature drift compensation is realized. Using a simple likewise concentric glass tube inside the inner...

  • A variable pressure/temperature scanning tunneling microscope for surface science and catalysis studies. McIntyre, B. J.; Salmeron, M.; Somorjai, G. A. // Review of Scientific Instruments;Mar93, Vol. 64 Issue 3, p687 

    We describe the design and construction of a scanning tunneling microscope (STM), which is contained in a reactor cell and allows in situ operation throughout a wide range of pressures and temperatures. This STM is capable of imaging in pressures ranging from ultrahigh vacuum up to several...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics