TITLE

On the temporal resolution of multitau digital correlators

AUTHOR(S)
Phillies, George D.J.
PUB. DATE
October 1996
SOURCE
Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3423
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Studies the temporal resolution of multitau digital correlators. Variety of implementations of a multitau instrument; Average delay times; Consequences of correlator time resolution.
ACCESSION #
4295472

 

Related Articles

  • Hardware simulator for photon correlation spectroscopy. Ferri, Fabio; Magatti, Davide // Review of Scientific Instruments;Oct2003, Vol. 74 Issue 10, p4273 

    We present a hardware simulator ideal for testing digital correlators in photon correlation spectroscopy. By using a PCI-6534 National Instrument I/O board, a personal computer (1.5 GHz Pentium 4), and an original algorithm developed in LabVIEW (National Instrumentâ„¢), we realized an...

  • Spectroscopy with multichannel correlation radiometers. Harris, A. I. // Review of Scientific Instruments;May2005, Vol. 76 Issue 5, p054503 

    Correlation radiometers make true differential measurements in power with high accuracy and small systematic errors. This receiver architecture has been used in radio astronomy for measurements of continuum radiation for over 50 years; in this article, spectroscopy over broad bandwidths using...

  • Comparison of Goodness of Fit Statistics for Linear Regression, Part I.  // Spectroscopy;Apr2004, Vol. 19 Issue 4, p38 

    Provides statistical tools described to compare and correlate two or more data sets. Software used for the pedagogical exercise; Assumptions made for performing linear regression computations; Use of linear regression as a statistical tool.

  • COMPUTING INTERCORRELATIONS OF TESTS ON THE ADDING MACHINE. Toops, Herbert A. // Journal of Applied Psychology;Jun22, Vol. 6 Issue 2, p172 

    The article presents a procedure for computing intercorrelations of tests on the adding machine. The procedure is based on a formula where X and Y stand for the gross measures of transmuted scores. The speed of the calculation depends on the fact that the transmuted scores are small in magnitude...

  • Autocorrelator consisting of a solar-blind photomultiplier for use in the near-ultraviolet region. Ihara, K.; Zaitsu, S.; Imasaka, T. // Review of Scientific Instruments;Feb2005, Vol. 76 Issue 2, p026109 

    The development of an autocorrelator based on a two-photon absorption of a photomultiplier photocathode is described. A solar-blind photomultiplier, sensitive in the far-ultraviolet region, is used to detect a two-photon absorption in the near-ultraviolet region. Such an autocorrelator can be...

  • Combining ferromagnetic resonator and digital image correlation to study the strain induced resonance tunability in magnetoelectric heterostructures. Zighem, Fatih; Belmeguenai, Mohamed; Faurie, Damien; Haddadi, Halim; Moulin, Johan // Review of Scientific Instruments;2014, Vol. 85 Issue 10, p1 

    This paper reports the development of a methodology combining microstrip ferromagnetic resonance and digital image correlation in order to simultaneously measure the voltage-induced strains and the magnetic resonance in artificial magnetoelectric heterostructures ("magnetic films/piezoelectric...

  • Novel scanning electron microscope bulge test technique integrated with loading function. Chuanwei Li; Zhanwei Liu; Huimin Xie // Review of Scientific Instruments;2014, Vol. 85 Issue 10, p1 

    Membranes and film-on-substrate structures are critical elements for some devices in electronics industry and for Micro Electro Mechanical Systems devices. These structures are normally at the scale of micrometer or even nanometer. Thus, the measurement for the mechanical property of these...

  • A 32-channel photon counting module with embedded auto/cross-correlators for real-time parallel ?uorescence correlation spectroscopy. Gong, S.; Labanca, I.; Rech, I.; Ghioni, M. // Review of Scientific Instruments;2014, Vol. 85 Issue 10, p1 

    Fluorescence correlation spectroscopy (FCS) is a well-established technique to study binding interactions or the diffusion of fluorescently labeled biomolecules in vitro and in vivo. Fast FCS experiments require parallel data acquisition and analysis which can be achieved by exploiting a...

  • Accurate three-dimensional shape and deformation measurement at microscale using digital image correlation. Maodong Ren; Jin Liang; Leigang Li; Bin Wei; Lizhong Wang; Zhengzong Tang // Review of Scientific Instruments;Jul2015, Vol. 86 Issue 7, p1 

    Based on stereomicroscope and three-dimensional (3D) digital image correlation (DIC) method, a non-contact measurement technique is presented to measure the 3D shape and deformation data on miniature specimens and the corresponding microscopic measurement system is developed. A pair of cameras...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics