TITLE

Design aspects of a ruby-based fiber optic thermometer probe for use in the cryogenic region

AUTHOR(S)
Hu, Y.L.; Zhang, Z.Y.; Grattan, K.T.V.; Palmer, A.W.; Meggitt, B.T.
PUB. DATE
June 1996
SOURCE
Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2394
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Investigates the effect of fluorescence reabsorption on fiber optic decay-time based fluorescence thermometry. Sensor probe's use of a Y-junction fiber coupler for the excitation of light and return of light in the probe; Modulation of the pumping light intensity; Signal processing.
ACCESSION #
4295457

 

Related Articles

  • Analysis of dopant concentration effects in praseodymium-based fluorescent fiber optic temperature sensors. Mitchell, I. R.; Mitchell, I.R.; Farrell, P. M.; Farrell, P.M.; Baxter, G. W.; Baxler, G.W.; Collins, S. F.; Collins, S.F.; Grattan, K. T. V.; Grattan, K.T.V.; Sun, T. // Review of Scientific Instruments;Jan2000, Vol. 71 Issue 1 

    An analysis of concentration effects in praseodymium-doped glasses used as the sensor element of several fiber optic temperature sensors has been performed. Results show the dependence of a range of relevant parameters on concentration, and the determination of concentration-independent...

  • Scanning optical pyrometer for measuring temperatures in hollow cathodes. Polk, J. E.; Marrese-Reading, C. M.; Thornber, B.; Dang, L.; Johnson, L. K.; Katz, I. // Review of Scientific Instruments;Sep2007, Vol. 78 Issue 9, p093101 

    Life-limiting processes in hollow cathodes are determined largely by the temperature of the electron emitter. To support cathode life assessment, a noncontact temperature measurement technique which employs a stepper motor-driven fiber optic probe was developed. The probe is driven inside the...

  • Fiber-optic talk sets.  // Cabling Installation & Maintenance;Mar1995, Vol. 3 Issue 3, p160 

    Lists fiber-optic talk sets in the United States. Manufacturers; Product description; Single- or multi-mode; Operating wavelength in nanometers; Standards compliance.

  • Isolation instrumentation.  // Design News;12/26/94, Vol. 50 Issue 25, p353 

    Lists companies in the United States that manufacture fiber optic isolation instrumentation links. Includes Dymec Inc.; Meret Optical Communications Inc.; Phoenix Contact Inc.

  • Response compensation of thermistors: Frequency response and identification of thermal time constant. Tagawa, M.; Kato, K.; Ohta, Y. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1350 

    The purpose of this study is to improve the accuracy of general-purpose temperature sensors (commercially available thermistors) in fluctuating temperature measurement and to extend their applicability. First, heat transfer models reflecting the internal structures of plate-type and spherical...

  • An instrument for the heat flux measurement from a contour of a surface with uniform temperature. Baughn, J. W.; Hoffman, M. A.; Lee, Daehee // Review of Scientific Instruments;Mar94, Vol. 65 Issue 3, p689 

    An instrument for the measurement of the heat flux distribution along an internal or external contour of a surface with a uniform temperature is described. The main element in this instrument is an electrically heated narrow nickel/chromium ribbon which is mounted flush with, but thermally and...

  • Improved hot-wire procedure for thermophysical measurements under pressure. Håkansson, B.; Andersson, P.; Bäckström, G. // Review of Scientific Instruments;Oct88, Vol. 59 Issue 10, p2269 

    A new and simplified version of the circuitry for the transient hot-wire method is presented. The circuitry provides a wide range of currents allowing probe wires of various diameters to be used in order to match the thermal properties of the specimen to be investigated. The analysis of the...

  • Picosecond flash photolysis apparatus with high absorbance resolution. Ebbesen, Thomas W. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1307 

    A new picosecond flash photolysis apparatus is described which makes extensive use of fiber optics in the probing beam pathway. The apparatus is simple and easy to use. The absorbance resolution and accuracy are greatly enhanced and allow for quantitative determination of properties of transient...

  • Gauge for nondestructive measurement of the internal pressure in powder-filled evacuated panel superinsulation. Kollie, Thomas G.; Thacker, L. H. // Review of Scientific Instruments;Dec1992, Vol. 63 Issue 12, p5774 

    A gauge that measures the internal pressure (P) in powder-filled evacuated panels (PEPs) is described. PEPs are superinsulators consisting of high thermal resistivity powders encapsulated in hermetically sealed flexible barriers enclosing a vacuum. To measure P, the gauge supplies a vacuum to...