TITLE

Photoelectron imaging spectrometry: Principle and inversion method

AUTHOR(S)
Bordas, C.; Paulig, F.; Helm, H.; Huestis, D.L.
PUB. DATE
June 1996
SOURCE
Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2257
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Reports on the use of a photoelectron spectrometer to analyze the energy and spatial distribution of photoelectrons produced by multiphoton ionization of rare gases. Projection of the expanding electron cloud resulting from the ionization process; Principle of the imaging spectrometer and relevant equations of motions of the charged particle in the device.
ACCESSION #
4295434

 

Related Articles

  • Fabrication and characterization of reactive ion beam etched SiC gratings. Ishiguro, E.; Yamashita, K.; Ohashi, H.; Sakurai, M.; Aita, O.; Watanabe, M.; Sano, K.; Koeda, M.; Nagano, T. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1439 

    A holographic SiC grating has been fabricated by means of reactive ion beam etching in Ar + CHF[sub 3] mixture and by using photoresist as an etching mask. The etch rates of SiC and photoresist depend on the CHF[sub 3] concentration in Ar + CHF[sub 3] mixture. A maximum value for a ratio of the...

  • Multichannel ellipsometer for real time spectroscopy of thin film deposition from 1.5 to 6.5 eV. Zapien, J. A.; Zapien, J.A.; Collins, R. W.; Collins, R.W.; Messier, R. // Review of Scientific Instruments;Sep2000, Vol. 71 Issue 9 

    A rotating polarizer multichannel ellipsometer has been optimized for operation well into the ultraviolet (UV) spectral range. With this instrument, 132 spectral points in the ellipsometric parameters (ψ, Δ) over the photon energy range from 1.5 eV (827 nm) to 6.5 eV (191 nm) can be...

  • High-order laser harmonics detection in the EUV and soft x-ray spectral regions. Poletto, Luca; Tondello, Giuseppe; Villoresi, Paolo // Review of Scientific Instruments;Jul2001, Vol. 72 Issue 7, p2868 

    The design and performance of a spectroscopic instrument able to simultaneously measure spectral features, angular divergence, and conversion efficiency of high-order harmonics generated by an ultrashort pulsed laser focused onto a gas jet are presented. It combines an advanced optical setup...

  • Calibration technique of time lag between nonsynchronous, ultrafast digitizers for dual homodyne spectroscopy. Nagatsu, Masaaki; Ariga, Hiroo; Tsukishima, Takashige // Review of Scientific Instruments;Apr93, Vol. 64 Issue 4, p1021 

    In situ calibration technique of time lag between nonsynchronous, ultrafast wave form digitizers with a sampling frequency of 1.35 GHz has been developed for application to the dual homodyne receiver system for the ion Thomson scattering experiment. By making use of the proposed calibration...

  • CAMAC-PC analyzer for neutron slowing-down-time spectrometry. Baczynski, Janusz // Review of Scientific Instruments;Apr90, Vol. 61 Issue 4, p1340 

    A personal computer controlled CAMAC analyzer for time resolved spectroscopy and the design of a specially interfaced CAMAC module for routing data are described. The system is intended for spectroscopic data acquisition of slowing-down-time or time-of-flight neutron spectrometers. Its maximum...

  • Shimadzu Scientific Instruments.  // Spectroscopy;Dec2008, Vol. 23 Issue 12, p66 

    The article features the Columbia, Maryland-based company Shimadzu Scientific Instruments, the North American subsidiary of Shimadzu Corp., which offers analytical, laboratory and medical diagnostic instrumentation. It provides information on the markets it served, major products and services,...

  • Ion Feedback Afterpulses in ФЭУ-130 and XP2020 Photomultipliers. Brudanin, V. B.; Morozov, V. A.; Morozova, N. V. // Instruments & Experimental Techniques;Nov/Dec2004, Vol. 47 Issue 6, p783 

    Intensities and time distribution spectra of ion feedback afterpulses were studied as a function of the potential differences between the photocathode and first dynodes in ФЭУ-130 photomultipliers with the aim of using this type of photomultiplier in autocorrelation delayed-coincidence...

  • Harsh environments dictate design of imaging spectrometer. Bannon, David; Thomas, Robert // Laser Focus World;Aug2005, Vol. 41 Issue 8, p93 

    Focuses on the design of spectrometers for use in remote field application. Necessity for the product design to be base on reflective optics; Suitability to place multiple spectral regions onto a single detector plane; Limitations of the Czerny-Turner planar design.

  • Precise measurements of the total concentration of atmospheric CO2 and 13CO2/12CO2 isotopic ratio using a lead-salt laser diode spectrometer. Croizé, Laurence; Mondelain, Didier; Camy-Peyret, Claude; Delmotte, Marc; Schmidt, Martina // Review of Scientific Instruments;Apr2008, Vol. 79 Issue 4, p043101 

    We have developed a tunable diode laser spectrometer, called SIMCO (spectrometer for isotopic measurements of CO2), for determining the concentrations of 12CO2 and 13CO2 in atmospheric air, from which the total concentration of CO2 and the isotopic composition (expressed in delta units)...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics