TITLE

Photodetachment diagnostics of plasma with a high n_ln[sub e] ratio

AUTHOR(S)
El Balghiti-Sube, F.; Baksht, F.G.; Bacal, M.
PUB. DATE
June 1996
SOURCE
Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2221
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses a method of determination of the electron and hydrogen negative ion densities in the photodetachment experiment. Creation of a potential well in plasma after photodetachment; Capture of excess electrons in the well; Dependencies of the negative ion and electron densities and of electron temperature upon the plasma electrode voltage.
ACCESSION #
4295429

 

Related Articles

  • Phase contrast imaging interferometer for edge density fluctuation measurements on LHD. Tanaka, K.; Vyacheslavov, L. N.; Akiyama, T.; Sanin, A.; Kawahata, K.; Tokuzawa, T.; Ito, Y.; Tsuji-Iio, S.; Okajma, S. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1633 

    A phase contrast interferometer employing a CO[sub 2] laser (wavelength λ[sub i] = 10.6 µm) is designed and installed in order to study density fluctuations on a large helical device. A 250×50 mm slab beam passes the edge of the plasma, where ρ = r/a > 0.65, and provides...

  • Development of a multichannel far-infrared tangential interferometer/polarimeter for the National Spherical Torus Experiment. Deng, B. H.; Chen, H. C.; Domier, C. W.; Johnson, M.; Lee, K. C.; Luhmann, N. C.; Nathan, B. R.; Park, H. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1617 

    Completion of a multichannel far-infrared (FIR) tangential interferometer/polarimeter is under way for the National Spherical Torus Experiment, for the measurement of plasma electron density and toroidal magnetic-field distributions. The system is based on the three-wavelength configuration,...

  • On the use of the analytic signal to retrieve the phase from broadband reflectometry signals. Figueiredo, António C. A.; Bizarro, João P. S. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1514 

    Uniformly redundant arrays (URA) is one coded aperture imaging technique. Since the URA camera can view the object with a large solid angle, it can provide some tomographic resolution for a three-dimensional object. The performance of a URA camera for three-dimensional imaging has been...

  • CO[sub 2] laser imaging interferometer for high spatial resolution electron density profile measurements on LHD. Akiyama, T.; Tanaka, K.; Vyacheslavov, L. N.; Sanin, A.; Tokuzawa, T.; Ito, Y.; Tsuji-Iio, S.; Okajima, S.; Kawahata, K. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1638 

    A CO[sub 2] laser (∼ = 10.6 µm) imaging interferometer was developed for detailed and precise electron density profile measurements and was installed on the large helical device in 2001. A CO[sub 2] laser is adopted to avoid fringe loss due to the short wavelength. An imaging scheme is...

  • First results from the multichannel interferometer system on HSX. Deng, C.; Brower, D. L.; Ding, W. X.; Almagri, A. F.; Anderson, D. T.; Anderson, F. S. B.; Gerhardt, S. P.; Probert, P.; Talmadge, J. N. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1625 

    Measuring the equilibrium electron density distribution and its response to perturbations provides important information to magnetically confined plasma research. A multichannel interferometer system is now routinely operating on the new quasihelically symmetric stellator (HSX) to measure the...

  • Time-of-flight refractometry for robust line integral electron density measurements and control in ITER. Petrov, A. A.; Petrov, V. G. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1465 

    A new method of electron density measurements in magnetic confinement plasmas—time-of-flight refractometry (TFR)—is proposed for application in the International Thermonuclear Experimental Reactor (ITER) in order to get robust line integral electron density information. The method...

  • Improved reflectometer electron density profile measurements on DIII-D. Wang, G.; Zeng, L.; Doyle, E. J.; Rhodes, T. L.; Peebles, W. A. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1525 

    Details are presented of recent improvements to hardware and analysis code components of the DIII-D density profile reflectometer system. The improvements to the hardware increased the system signal-to-noise ratio and reduced spurious reflections. An improved automated method is developed to...

  • On a variational approach to the extraction of quadratures from broadband reflectometry signals. Figueiredo, Anto´nio C. A.; Bizarro, Joa˜o P. S. // Review of Scientific Instruments;Feb2002, Vol. 73 Issue 2, p289 

    A variational method is employed to retrieve the phase from broadband reflectometry signals. The method yields the so-called in-phase and quadrature components of a signal (the signal quadratures in short), by stipulating that these should have the smallest possible amount of functional...

  • Density determination in the TEXTOR boundary layer by laser-ablated fast lithium atoms. Pospieszczyk, A.; Ross, G. G. // Review of Scientific Instruments;Apr88, Vol. 59 Issue 4, p605 

    A method is presented which allows a determination of electron density profiles in the plasma boundary of a fusion device up to some 10[sup 13] cm[sup -3] within about 100 µs. For this purpose, the complete attenuation of an injected lithium beam is determined by measuring its optical...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics