TITLE

Low-cost, heated, and/or cooled flow-through cell for transmission x-ray absorption spectroscopy

AUTHOR(S)
Jentoft, R.E.; Deutsch, S.E.; Gates, B.C.
PUB. DATE
June 1996
SOURCE
Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2111
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a transmission x-ray absorption spectroscopy cell that can be used for air-sensitive samples with in situ treatment. Use of gas flows or vacuum to treat samples in situ; Materials used in cell construction; Cell cost.
ACCESSION #
4295409

 

Related Articles

  • X-ray spectral power measurements utilizing the diffraction pattern of a slit. Baker, K.L.; Porter, J.L.; Ruggles, L.E.; Chrien, R.E.; Idzorek, G.C. // Review of Scientific Instruments;Mar99, Vol. 70 Issue 3, p1624 

    Describes an instrument that can obtain x-ray spectral power measurements utilizing the diffraction pattern produced when x-rays pass through a slit. Advantages over filtered x-ray diodes in determining spectral power profile; Non-requirement of the use of filters that can be destroyed during a...

  • High-pressure, capillary x-ray absorption fine structure cell for studies of liquid and... Wallen, Scott L.; Pfund, David M. // Review of Scientific Instruments;Aug1996, Vol. 67 Issue 8, p2843 

    Describes an apparatus designed to acquire x-ray absorption fine structure (XAFS) spectra of high-pressure liquid and supercritical fluid solutions. Application of XAFS spectroscopy; Factors cited for the paucity of studies conducted on XAFS; Advice that planned improvements of the technique...

  • A compact point focusing spatial filter for x-ray fluorescence and inelastic x-ray scattering studies. Behne, E. A.; Feng, Yejun; Seidler, G. T. // Review of Scientific Instruments;Oct2001, Vol. 72 Issue 10, p3908 

    Appropriately selected absorbers combined with spatial filters are frequently used as x-ray low-pass filters in inelastic x-ray scattering studies and x-ray fluorescence spectroscopies. We describe here a compact point focusing spatial filter with a large collection solid angle and excellent...

  • EDXRF Analysis of Coal by FP Method. Fess, Scott // Spectroscopy;Feb2013 Supplement, p12 

    The article evaluates Rigaku NEX CG EDXRF spectrometer, a type of dispersive X-ray fluorescence (EDXRF) spectrometer, from Applied Rigaku Technologies Inc.

  • Soft x-ray magnetic circular dichroism at 2 K: A tool in biological inorganic chemistry. Funk, T.; Friedrich, S.; Young, A.T.; Arenholz, E.; Delano, R.; Cramer, S.P. // Review of Scientific Instruments;Mar2004, Vol. 75 Issue 3, p756 

    X-ray magnetic circular dichroism (XMCD) is the asymmetric absorption of left- and right-handed circularly polarized x rays and can be used to measure element-specific spin and oxidation states and magnetic moments. We have built an end station for XMCD spectroscopy to study transition metals...

  • Determination of concentration depth profiles using total-reflection x-ray fluorescence... Gunther, R.; Wiener, G.; Knoth, J.; Schwenke, H.; Bormann, R. // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2332 

    Presents a method for quantitative concentration depth profiling. Combination of a sputter-etching technique with ex-situ total reflection x-ray fluorescence analysis; Basic requirements for a high depth resolution.

  • Temperature-dependent sample holder for x-ray spectrometer. Jonnard, P.; Chargelegue, P.; Hombourger, C.; Thirion, J.; Vergand, F. // Review of Scientific Instruments;Jun96, Vol. 67 Issue 6, p2417 

    Describes a temperature-regulated sample holder of the x-ray spectrometer IRIS. Use of a closed helium gas cycle by the refrigerator which cools the sample holder; Working temperatures obtained; System's production of a high-resolution spectra.

  • Portable XRF analyzers.  // Spectroscopy;Feb2006, Vol. 21 Issue 2, p79 

    The article describes the Alpha series handheld X-ray fluorescence analyzers from Woburn, Massachusetts-based Innov-X Systems Inc. The analyzers are designed to provide fast, precise and nondestructive elemental identification in materials ranging from plastics, soils and alloys. Interested...

  • Demonstration of reduced source size broadening with a Johann focusing elliptical spectrograph and theory of the second-order source broadening. Hammel, B. A.; Phillion, D. W.; Ruggles, L. E. // Review of Scientific Instruments;Jul1990, Vol. 61 Issue 7, p1920 

    A Johann focusing elliptical spectrograph has been developed for the measurement of high-resolution x-ray spectra from a spatially extended source. The instrument was designed for the study of high-density, high-temperature plasmas produced by z-pinch implosion or ion-beam bombardment on...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics