ABSTRACT
Describes the development of an optical device called a multichannel collimator (MCC) to rapidly perform an angle-dispersive diffraction using a multi-anvil press with synchrotron radiation. Components of the MCC system; Installation of the system at the Photon Factory in Japan's National Laboratory for High Energy Physics; Achievement of diffraction patterns.
ACCESSION #
4290439

 

Related Articles

  • Coherent addition of AlGaAs lasers using microlenses and diffractive coupling. Leger, James R.; Scott, Miles L.; Veldkamp, Wilfrid B. // Applied Physics Letters;5/23/1988, Vol. 52 Issue 21, p1771 

    A near single-lobed far-field pattern was obtained from coherent operation of a nonevanescently coupled AlGaAs laser diode array. A diffractive microlens array collimated the individual beams to approximate a plane wave, and diffractive coupling from an external cavity mirror provided mutual...

  • New long trace profiler based on phase plate diffraction for optical metrology of SSRF. Zeng, Danhua; Xiao, Tiqiao; Du, Guohao; Wen, Li; Luo, Hongxin; Xia, Shaojian; Xu, Hongjie // Review of Scientific Instruments;Sep2006, Vol. 77 Issue 9, p093305 

    A long trace profiler LTP-1200, with a novel f-θ system based on phase plate diffraction and a scanning range up to 1200 mm, has been developed at Shanghai Synchrotron Radiation Facility. The central dark line in the diffraction pattern generated by a π phase plate is taken as the...

  • Kratky block-collimation small-angle x-ray diffractometer for synchrotron radiation. Chu, Benjamin; Wu, D.-Q.; Wu, C. // Review of Scientific Instruments;Jul1987, Vol. 58 Issue 7, p1158 

    A block slit collimation system of the Kratky design concept has been modified and adapted for synchrotron radiation. The building block small-angle x-ray diffractometer (SAXD) not only retains the essential advantages of the Kratky camera, i.e., accessibility at small values of...

  • A refractive collimator for synchrotron radiation. Baron, A.Q.R.; Kohmura, Y. // Applied Physics Letters;3/8/1999, Vol. 74 Issue 10, p1492 

    Studies the use of a plastic refractive lens to collimate synchrotron radiation. Reduction of the divergence of a radiation beam from an undulator; Incident radiation from a distant point source; Principle behind a refractive collimator.

  • Formation of Multiple Longitudinal High-Absorption Kinks under the Action of Collimated Gaussian Light Beams. Vysloukh, A. V.; Trofimov, V. A. // Technical Physics Letters;Feb2000, Vol. 26 Issue 2, p119 

    The possibility of formation of several longitudinal kinks under the action of a collimated Gaussian light beam in a medium with absorptive cavityless optical bistability is demonstrated to be possible. The beam is essentially affected by diffraction. The domain formation is caused by the...

  • A laser-aided prealigned pinhole collimator for synchrotron x rays. Chu, Benjamin; Harney, Paul J.; Li, Yingjie; Linliu, Kung; Yeh, Fengji; Hsiao, Benjamin S. // Review of Scientific Instruments;Mar94, Vol. 65 Issue 3, p597 

    A pinhole small-angle x-ray scattering (SAXS) instrument was constructed at the SUNY X3A2 beamline, National Synchrotron Light Source, Brookhaven National Laboratory. The three pinholes were mounted in a thick-walled stainless steel pipe and prealigned by using a portable laser source and a...

  • Z-shaped wire profile and position monitor for collimated synchrotron radiation using a single linear motion. Kanazawa, K. // Review of Scientific Instruments;Nov86, Vol. 57 Issue 11, p2891 

    A simple position and profile monitor for collimated synchrotron radiation (SR) using only one linear motion feedthrough was constructed and successfully employed to align the SR beam line of the TRISTAN accumulation ring.

  • Ideal collimation, concentration, and imaging with curved diffractive optical elements. Bokor, Nándor; Davidson, Nir // Review of Scientific Instruments;Nov2005, Vol. 76 Issue 11, p111101 

    In this article the design, optimization and characterization of diffractive optical elements formed on a curved surface are reviewed. For such curved diffractive optical elements not only the phase function, but also the surface shape are free parameters that can be used for optimization,...

  • Meandering collimated beam of surface acoustic waves on a trigonal crystal ball. Yanagisawa, Takayuki; Ohgi, Tsuneo; Akao, Shingo; Nakaso, Noritaka; Tsukahara, Yusuke; Ohara, Yoshikazu; Tsuji, Toshihiro; Yamanaka, Kazushi // Applied Physics Letters;3/21/2011, Vol. 98 Issue 12, p123508 

    To fully exploit high-quality piezoelectric crystals in acoustic wave devices, it is necessary to remove limitations not related to the crystal quality. Among them, the 'diffraction loss' is most serious. Previously, we have developed the ball surface acoustic wave (SAW) sensor using crystal...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics