TITLE

A miniature total-electron-yield detector for the measurement of x-ray absorption spectra

AUTHOR(S)
Harris, V.G.; Elam, W.T.
PUB. DATE
May 1997
SOURCE
Review of Scientific Instruments;May97, Vol. 68 Issue 5, p1972
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the design, fabrication and testing of a total-electron-yield detector for the collection of x-ray absorption spectra. Design and operation; Data collection system; Instrument efficiency.
ACCESSION #
4290416

 

Related Articles

  • Measurement of the Energy Resolution of Silicon X-Ray Detectors Using Absorption Edge Spectra. Osadchii, S. M.; Petukhov, A. A.; Dunin, V. B. // Measurement Techniques;Aug2019, Vol. 62 Issue 5, p465 

    A silicon detector with a longitudinal silicon wafer has been developed. x-Ray spectra at the K-absorption edges of Au, Pb, and Bi are used to measure its energy resolution. The results are compared with measurements based on x-rays from a 241Am gamma-ray source. The dependence of the energy...

  • Spectral resolution for a five-element, filtered, x-ray detector array using the method of Backus and Gilbert. Fehl, D. L.; Fehl, D.L.; Biggs, F.; Chandler, G. A.; Chandler, G.A.; Stygar, W. A.; Stygar, W.A. // Review of Scientific Instruments;Aug2000, Vol. 71 Issue 8 

    The generalized method of Backus and Gilbert (BG) is described and applied to the inverse problem of obtaining the spectrum from a five-channel, filtered array of x-ray detectors. This diagnostic is routinely fielded on the Z facility at Sandia National Laboratories to study soft x-ray photons...

  • Superconducting single X-ray photon detector based on W0.8Si0.2. Xiaofu Zhang; Qiang Wang; Schilling, Andreas // AIP Advances;Nov2016, Vol. 6 Issue 11, p115104-1 

    We fabricated a superconducting single X-ray photon detector based on W0.8Si0.2, and we characterized its basic detection performance for keV-photons at different temperatures. The detector has a critical temperature of 4.97 K, and it is able to be operated up to 4.8 K, just below the critical...

  • Optical properties and thermal degradation of CdSe capped with 3-mercaptopropionic acid. Wageh, S.; Higazy, Anwer; Hassouna, Ahmed // Journal of Materials Science: Materials in Electronics;Aug2013, Vol. 24 Issue 8, p3049 

    We have prepared different sizes of CdSe nanoparticles capped by 3-mercaptopropionic acid (MPA) utilizing different cadmium sources and different molar ratios of the starting precursors. The prepared nanoparticles possess different Se/Cd ratios and different quantity of capping molecules as...

  • Alloyed Tetranuclear Metal Chains of Pd4−nPtn (n=0–3) Scaffolded by a New Linear Tetraphosphine Containing a PNP Bridge. Tanase, Tomoaki; Tanaka, Miho; Hamada, Mami; Morita, Yuka; Nakamae, Kanako; Ura, Yasuyuki; Nakajima, Takayuki // Chemistry - A European Journal;6/21/2019, Vol. 25 Issue 35, p8219 

    A new linear tetraphosphine containing a PNP phosphazane bridge, rac‐bis[(diphenylphosphinomethyl)phenylphosphino]phenylamine (rac‐dpmppan), was synthesized and utilized to support a series of Pd/Pt mixed metal tetranuclear chains,...

  • Ag-induced large perpendicular magnetic anisotropy in Mn/Ag/Fe(001). Kim, Dongyoo; Yang, Jeonghwa; Hong, Jisang // Journal of Applied Physics;Oct2011, Vol. 110 Issue 8, p083924 

    Using the full-potential, linearized, augmented plane wave method, we have investigated the magnetic properties of body-centered-cubic Mn(2 monolayers [ML])/Fe(001), Mn(2 ML)/ Ag(1 ML)/Fe(001), and Mn(2 ML)/Ag(2 ML)/Fe(001). We find that the Mn overlayers have a layered antiferromagnetic ground...

  • X-Ray Inspection Interference on a Germanium Spectroscopy Portal Monitor. Young, B. M.; Mettler, S. W.; Huckins, R.; Rotty, M. // Proceedings of the Institute of Nuclear Materials Management Ann;2009, p1 

    CANBERRA has deployed a Germanium Spectroscopic Portal (GSP) in the Port of Antwerp at a Central Examination Station (CES). The GSP will be used during secondary screening of cargo to identify any radiological materials present, particularly those that may have triggered an alarm during primary...

  • High Velocity Outflows in AGNs Observed with Gratings. Kaspi, Shai; Behar, Ehud // Space Science Reviews;Dec2010, Vol. 157 Issue 1-4, p249 

    Several Active Galactic Nuclei (AGNs) have been reported to harbor fast outflows exceeding 10,000 km s, which are detected mostly in their low-resolution CCD X-ray spectra. Only few, however, were detected with high-resolution grating spectrometers. Most of the grating detected outflows have...

  • Crystal field effect on X-ray magnetic circular dichroism spectra at the L absorption edges of mixed-valence Ce and Yb compounds in high magnetic fields. Kotani, A. // European Physical Journal B -- Condensed Matter;May2011, Vol. 81 Issue 1, p49 

    theoretical study is presented, with an extended single impurity Anderson model, for the crystal field effect on the X-ray magnetic circular dichroism (XMCD) spectra at L edges of mixed-valence Ce and Yb compounds in high magnetic fields. The crystal field acting on the 4 f electrons is assumed...

Share