TITLE

Characterization of the helical undulator HELIOS I in the 520 to 930 eV range using a multilayer

AUTHOR(S)
Drescher, M.; Snell, G.; Kleineberg, U.; Stock, H.-J.; Muller, N.; Heinzmann, U.; Brookes, N.B.
PUB. DATE
May 1997
SOURCE
Review of Scientific Instruments;May97, Vol. 68 Issue 5, p1939
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Utilizes a W/Si multilayer polarimeter to determine the degree of circular polarization of the soft x-ray radiation of the European Synchrotron Radiation Facility helical undulator HELIOS I. Fabrication of the multilayer polarimeter; Multilayer characterization; Determination of the degree of circular polarization; Characterization of HELIOS I.
ACCESSION #
4290412

 

Related Articles

  • Multilayer transmission phase shifters for the carbon K edge. Di Fonzo, S.; Muller, B.R.; Jark, W.; Gaupp, A.; Schafers, F.; Underwood, J.H. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1513 

    Explains how a polarization characterization of soft x-ray radiation with photon energies around and above 100 eV with primary standards was obtained via the introduction of multilayer transmission phase retarders. Description of the polarimeter; Polarization properties of the monochromatized...

  • The Milano polarization experiment devoted to the study of the cosmic microwave background. Gervasi, M.; Battistelli, E. S.; Boella, G.; Cavaliere, F.; Passerini, A.; Sironi, G.; Zannoni, M. // AIP Conference Proceedings;2002, Vol. 609 Issue 1, p164 

    In the last years several experiments have been devoted to the search for CMB polarization, but no positive detection has been obtained so far. In fact the expected degree of polarization is very low and its detection is extremely difficult. Very special design and system stability are necessary...

  • Optical converters for circularly polarized VUV and soft-x-ray radiation (invited) (abstract). Hochst, Hartmut // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1617 

    Presents an abstract of a paper focusing on optical converters for circularly polarized vacuum ultraviolet and soft-x-ray radiation. Method by which optical devices convert linearly polarized radiation; Phase-shifter designs; Potential capabilities of optical insertion devices as an alternative...

  • Magnetization profile in the MnIr/CoFe exchange bias system. Doi, Shuuichi; Awaji, Naoki; Nomura, Kenji; Hirono, Toko; Nakamura, Tetsuya; Kimura, Hiroaki // Applied Physics Letters;6/8/2009, Vol. 94 Issue 23, p232504 

    The element-specific magnetization profile in the Mn75Ir25/Co70Fe30 exchange bias system was studied by x-ray resonant magnetic reflectometry using circular polarized soft x rays. From the analysis of reflectivities obtained at Co L3 and Mn L3 absorption peak, we found the uncompensated Mn spins...

  • Polarization characterization of circularly polarized vacuum-ultraviolet and soft-x-ray helical... Koide, T.; Shidara, T.; Miyahara, T.; Yuri, M. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1923 

    Describes a vacuum-compatible reflection polarimeter that was designed and constructed to monitor the polarization state of circularly polarized radiation from a helical undulator installed on beamline BL-28A at Photon Factory in Tsukuba, Japan. Adjustment of the polarimeter's rotational axis;...

  • A polarimetric interferential radiometer. Marechek, S. // Instruments & Experimental Techniques;Jul2008, Vol. 51 Issue 4, p547 

    A polarimetric interferential radiometer operating in the L band and the procedure for measuring a full set of Stokes polarization parameters are described. It is shown that the interference principle of operation of the measuring system is intended to obtain the Stokes-polarization and...

  • High-efficiency spin-resolved and spin-integrated electron detection: Parallel mounting on a... Ghiringhelli, G.; Larsson, K.; Brookes, N.B. // Review of Scientific Instruments;Nov99, Vol. 70 Issue 11, p4225 

    Describes the installation of a compact kilovolt mini-Mott spin polarimeter on a commercial high-throughput hemispherical electron analyzer for the purpose of maximizing the polarization detection and to preserve the original efficiency of the spectrometer in the spin-integrated measurements. ...

  • Precision Lamb-shift polarimeter for polarized atomic and ion beams. Engels, R.; Emmerich, R.; Ley, J.; Tenckhoff, G.; Gen. Schieck, H. Paetz; Mikirtytchiants, M.; Rathmann, F.; Seyfarth, H.; Vassiliev, A. // Review of Scientific Instruments;Nov2003, Vol. 74 Issue 11, p4607 

    The Lamb-shift polarimeter described here enables the polarization of a beam of hydrogen (deuterium) atoms, or of a slow proton (deuteron) beam, to be measured with an absolute precision better than 1% within a few seconds. The polarimeter measures the intensity ratios of Lyman-α transitions...

  • Workshop report on spin polarized electron source and polarimeter. Nakanishi, T. // AIP Conference Proceedings;2001, Vol. 570 Issue 1, p274 

    Three days satellite-workshop on polarized electron source (PES) and polarimeter was held at Iris-Aichi hotel in Nagoya during Oct. 12 to 14, just prior to the Spin-2000 symposium. This is the seventh in a row of similar satellite-workshop, which was first held at Stanford in 1983. It is a good...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics