TITLE

Nitrogen laser system for diagnosing z-pinch and x-pinch plasmas

AUTHOR(S)
Kalantar, Daniel H.; Hammer, David A.
PUB. DATE
July 1997
SOURCE
Review of Scientific Instruments;Jul97, Vol. 68 Issue 7, p2725
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a nitrogen laser system built to probe dense z-pinch and x-pinch plasmas. Components of the nitrogen laser; Atmospheric pressure oscillator component; Laser characterization.
ACCESSION #
4272740

 

Related Articles

  • High intensity alkali ion sources for plasma diagnostics. Bondarenko, I. S.; Chmyga, O. O.; Dreval, M. B.; Khrebtov, S. M.; Komarov, O. D.; Kozachok, O. S.; Krupnik, L. I.; Nedzelskiy, I. S.; Schweinzer, J. // Review of Scientific Instruments;May2004, Vol. 75 Issue 5, p1826 

    The injection systems of heavy ion beam probe (HIBP) and beam emission spectroscopy plasma diagnostics must produce a beam with a high enough intensity to obtain a reliable secondary signal. In particular, it can be achieved by improvements and optimization of the ion sources. Among a variety of...

  • Investigating the momentum balance of a plasma pinch: An air-side stereoscopic imaging system for locating probes. Sears, Jason; Intrator, T. P.; Feng, Y.; Swan, H. O.; Klarenbeek, J.; Gao, K. // Review of Scientific Instruments;2014, Vol. 85 Issue 10, p1 

    The momentum balance of a plasma pinch in the Reconnection Scaling Experiment (RSX) is examined in three dimensions using several repositionable, insertable probes. A new camera-based system described here triangulates the locations of the probe tips so that their measurements are spatially...

  • Study of Pinching Capillary Discharge for Nitrogen H-like Recombination Laser. Vrba, Pavel; Vrbova, Miroslava; Jancarek, Alexandr; Pina, Ladislav; Havlikova, Radka // AIP Conference Proceedings;2006, Vol. 808 Issue 1, p263 

    A computer model of EUV nitrogen laser pumped by pinching capillary discharge is presented. The model consists of magneto-hydrodynamics plasma description and subsequent ion kinetic evaluation. Quick changes of electron temperature during the pinch decay lead to ionisation and excitation...

  • Soft x-ray output from a pinch plasma using laser-induced Au plasma. Ohzu, Akira; Ito, Kazunori // Review of Scientific Instruments;Aug2002, Vol. 73 Issue 8, p3131 

    An experimental investigation of the characteristics of soft x-ray output emitted from a pinch plasma using a laser-induced Au plasma has been performed. The Au plasma is produced by focusing a laser pulse with a focal spot diameter of 100 µm on the tip of an Au pin anode electrode. A pulsed...

  • Measurements of near forward scattered laser light in a large inertial confinement fusion plasma... Moody, J.D.; MacGowan, B.J.; Glenzer, S.H.; Kirkwood, R.K.; Kruer, W.L.; Pollaine, S.M.; Williams, E.A.; Stone, G.F.; Afeyan, B.B.; Schmitt, A.J. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p677 

    Describes an instrument which measures the angular spread and spectrum of near forward scattered laser light from a probe beam in a long scalelength laser plasma. Two sensitivity detectors composing the instrument; Advantages of the mirror detection system over other techniques; Determination...

  • Multipoint Thomson scattering diagnostic for the Madison Symmetric Torus reversed-field pinch. Reusch, J. A.; Borchardt, M. T.; Den Hartog, D. J.; Falkowski, A. F.; Holly, D. J.; O’Connell, R.; Stephens, H. D. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E733 

    The multipoint Thomson scattering diagnostic on the Madison Symmetric Torus (MST) is now fully operational with 21 spatial points, which cover the entire minor radius. Four full electron temperature profiles can be obtained during each MST discharge, with a variable delay between each profile....

  • Influence of Z-pinch evolution on laser pulse duration at 46.9 nm in Ne-like Ar ions. Zhao, Y. P.; Jiang, S.; Xie, Y.; Wang, Q. // Applied Physics B: Lasers & Optics;May2010, Vol. 99 Issue 3, p535 

    A capillary discharge 46.9 nm Ne-like Ar laser is achieved with peak current of 20–23 kA. The variation of laser pulse duration with initial Ar pressure and rise-time of main current is reported. Measurements show that the laser pulse durations slightly increase with the increased...

  • Magnetic Field Measurements in Wire-Array Z-Pinches and X Pinches. Syed, W.; Hammer, D. A.; Lipson, M.; van Dover, R. B. // AIP Conference Proceedings;2006, Vol. 808 Issue 1, p315 

    We are investigating several techniques to obtain time-dependent magnetic field measurements in wire-array Z-pinches and X-pinches. One general approach is to use “remote sensing” methods whereby a very small sensor material is placed in the plasma and then is investigated to extract...

  • Elliptical spectrograph/gated microchannel-plate detector for time-resolved spectral measurements in the x-ray region. Hammel, B. A.; Ruggles, L. E. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1828 

    Time-resolved measurements from an elliptical crystal spectrograph are used to diagnose x-ray laser experiments on a gas puff Z pinch. The elliptical spectrograph (1.2-m working distance, eccentricity 0.9586) observes the 1-keV region, covering a range of λ/2d = 0.5 to 0.9. A thin filter (0.2...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library