TITLE

Frequency response of metal-clad inductive magnetic field probes

AUTHOR(S)
Strait, E.J.
PUB. DATE
July 1996
SOURCE
Review of Scientific Instruments;Jul96, Vol. 67 Issue 7, p2538
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents a calculation of the frequency response of an inductive magnetic field probe enclosed in a metal shell, including the effect of inductive coupling between the probe coil and the shell. Extension of the bandwidth beyond the cutoff frequency of the shell; Accuracy of predicting the behavior of magnetic probes in the DIII-D tokamak.
ACCESSION #
4271706

 

Related Articles

  • Electrical measurements with a SQUlD susceptometer. Wong, H. K. // Review of Scientific Instruments;Jun91, Vol. 62 Issue 6, p1664 

    We describe the design of a probe that can be inserted into a SQUID susceptometer (S.H.E. model VTS-805) for electrical measurements at variable temperature and high magnetic field. This top-loading probe allows multisample measurements and rapid sample replacement without disturbing the...

  • Electron holography in the study of the leakage field of magnetic force microscope sensor tips. Matteucci, G.; Muccini, M.; Hartmann, U. // Applied Physics Letters;4/12/1993, Vol. 62 Issue 15, p1839 

    Investigates the leakage magnetic field produced by sharp ferromagnetic probes. Application of electron holography; Obtainment of interference fringes; Evaluation of the phase difference in the simulated map of the dipole field.

  • Scanning Hall probe microscopy with shear force distance control. Schweinbo¨ck, Thomas; Weiss, Dieter; Lipinski, Martin; Eberl, Karl // Journal of Applied Physics;5/1/2000, Vol. 87 Issue 9, p6496 

    We describe a new type of scanning Hall probe microscope operating at room temperature for quantitative and noninvasive measurements of magnetic stray fields. The probe-sample distance is controlled by piezoelectrical detection of the shear forces acting on an oscillating cantilever. The Hall...

  • High accuracy magnetic field measurements with a Hall probe. Schott, C.; Popovic, R.S.; Alberti, S.; Tran, M.Q. // Review of Scientific Instruments;Jun99, Vol. 70 Issue 6, p2703 

    Describes a silicon-based temperature stabilized axial Hall probe with an absolute accuracy of +/-40 ppm in the range from 0 to 6 T. Hall probe configuration; Magnetic field configuration; Calibration procedure.

  • A calibration method of a radio frequency magnetic probe. Yang, J.G.; Choi, J.H.; Kim, B.C.; Yoon, N.S.; Hwang, S.M. // Review of Scientific Instruments;Sep99, Vol. 70 Issue 9, p3774 

    Demonstrates a simple calibration method of a radio frequency magnetic probe by utilizing a two port network analysis method. Measurement of the scattering parameters; Calculation of the magnetic field generated by the Helmholtz coil; Determination of probe sensitivity.

  • A probe for investigating the effects of temperature, strain, and magnetic field on transport critical currents in superconducting wires and tapes. Cheggour, Najib; Hampshire, Damian P. // Review of Scientific Instruments;Dec2000, Vol. 71 Issue 12 

    A variable-temperature probe has been developed to study the effect of strain on the transport properties of superconducting wires and tapes in high magnetic fields. The strain is applied to the wire by soldering it to a thick coiled spring and twisting one end of the spring with respect to the...

  • Magnetic probes for small-signal detection in a large background field. Chen, Xing // Review of Scientific Instruments;Apr88, Vol. 59 Issue 4, p616 

    High-precision Hail probes and B-dot probes are described. These probes are designed to measure magnetic field changes of a few gauss on a time scale of 2-3 s in a 5-kG background field. A digital, drift-free sample-and-hold circuit is used with the Hall probe to subtract the vacuum field.

  • A probe for magnetization measurements of thin superconducting films in pulsed high magnetic fields. Lagutin, A.S.; Vanacken, J.; Harrison, N.; Herlach, F. // Review of Scientific Instruments;Aug1995, Vol. 66 Issue 8, p4267 

    Describes an inductive magnetization sensor designed to measure thin superconducting films in very strong magnetic fields. Probe design and construction; Calibration procedure; Magnetization of the thin superconducting films.

  • Fluctuations of Current onto Flat Probes of the ZOND–ZARYAD Instrument Mounted on the MIR Orbital Complex. Lissakov, Yu. V.; Klimov, S. I.; Lapshinova, O. V.; Mednikov, B. A.; Mashkov, A. S.; Pushkin, N. M. // Cosmic Research;May/Jun2003, Vol. 41 Issue 3, p245 

    Flat probes of the ZOND–ZARYAD instrument, which operated on the MIR orbital complex (OC), form a counterprobe (reference surface) configuration in which the alternating component of the net probe current is measured. There is no potential difference between the spacecraft (SC) body and...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics