TITLE

Test of an 18-m-long suspended modecleaner cavity

AUTHOR(S)
Skeldon, K.D.; Strain, K.A.; Grant, A.I.; Hough, J.
PUB. DATE
July 1996
SOURCE
Review of Scientific Instruments;Jul96, Vol. 67 Issue 7, p2443
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a prototype modecleaner cavity with an optical path length of 18 meters and containing four suspended mirrors. Beam geometry noise in interferometers; Modecleaner filter for beam geometry noise; Design of a prototype suspended modecleaners; Performance of the prototype modecleaner.
ACCESSION #
4271691

 

Related Articles

  • A sensitive dispersion interferometer with high temporal resolution for electron density measurements. Licht, Valentin; Bluhm, Hansjoachim // Review of Scientific Instruments;Jul2000, Vol. 71 Issue 7 

    A dispersion interferometer with a sensitivity of up to 10[sup -4] fringe shifts and a time resolution of about 1 ns was developed. This time resolution exceeds previous systems by three orders. The operation of the dispersion interferometer and its characteristic properties are discussed and...

  • Microinterferometer for the hard x-ray range. Snigirev, A. A.; Suvorov, A. Yu. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1204 

    The properties of a multibolck microinterferometer (MI) treated as a collimating optic element have been theoretically analyzed. It is shown that under certain conditions the MI rocking curve gets much narrower compared with that of a single crystal. The numerical calculations of the rocking...

  • Signal averaging with a stabilized dual beam Mach Zehnder interferometer: Monitoring changes in gas density. Tardy, D. C. // Review of Scientific Instruments;Mar93, Vol. 64 Issue 3, p623 

    A traditional Mach Zehnder interferometer has been fitted with a feedback loop that maintains a constant and known phase difference between the two optical beams. This stabilization is necessary so that signal averaging will not distort the signal. To increase sensitivity for small phase shifts...

  • A multiple white light interferometer. Raz, Eli // Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3416 

    Discusses the development of a multiple interferometer using the short coherence length of white light. Ability of the system to count the number of light reflections between two parallel mirrors; Proportion of the shift in fringe position resulting from differences in the optical thickness to...

  • An optical interferometer for gas bubble measurements. Gelmetti, Andrea; Bellini, Tommaso; Lago, Paolo; Corti, Mario // Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3564 

    Describes a compact and stable interferometer for the measurement of the radius of a gas bubble in a liquid. Experimental configuration; Different techniques in performing the automatic determination of the bubble radius from the observed fringe profile.

  • A differential interferometer for force microscopy. Schönenberger, C.; Alvarado, S. F. // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3131 

    We present a polarizing optical interferometer especially developed for force microscopy. The deflections of the force-sensing cantilever are measured by means of the phase shift of two orthogonally polarized light beams, both reflected off the cantilever. This arrangement minimizes...

  • Using a fast lens to collect the signal in a VISAR system. Sweatt, William C.; Crump, O. B. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2946 

    VISAR (velocity interferometer system for any reflector) systems are used to measure the Doppler shift of a backscattered laser beam incident on a target, from whence the target's velocity can be calculated. In the past, slow lenses (F/4 or slower) have been used to collect the scattered light....

  • A VISAR with a multireflection étalon and its application in interior ballistics research. Wang, Shengyou; Cao, Caizhi; Sun, Jiangzheng // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2944 

    A VISAR (velocity interferometer system for any reflector) with a new type delay leg is described, which uses multireflection in the étalon for increasing the delay time τ. When the incident angle is changed, the sensitivity of the VISAR can be changed. A few step values of the...

  • A Stark-tuned laser application for interferometry and polarimetry on the National Spherical Torus Experiment. Lee, K. C.; Domier, C. W.; Deng, B. H.; Johnson, M.; Nathan, B. R.; Luhmann, N. C.; Park, H. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p1621 

    Interferometer/polarimeter systems based on far infrared lasers have suffered from lack of frequency modulation techniques that can allow higher intermediate frequency (IF) frequency for a fast time resolution together with stable operation including low frequency drift. This is mainly due to...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.