ABSTRACT
Presents a Bragg spectrometer for monitoring impurity radiation of hydrogenlike carbon and oxygen at the tokamak ASDEX Upgrade. Setup and calibration; Determination of carbon and oxygen concentrations; Applications.
ACCESSION #
4271646

 

Related Articles

  • USX and SX radiation measurement of tokamak plasma by microchannel plate. Kálvin, S.; Bakos, J. S.; Bürger, G.; Kardon, B.; Petravich, G.; Zoletnik, S. // Review of Scientific Instruments;Sep89, Vol. 60 Issue 9, p2857 

    A new method is described for the measurement of soft x-ray (SXR) and ultrasoft x-ray (USXR) radiation of fusion plasmas. The system applies the microchannel plate (MCP) detector and can be used to measure the emitted radiation along 12 chords in different energy ranges. The operation of the MCP...

  • JET high resolution bent crystal spectrometer. Bartiromo, R.; Bombarda, F.; Giannella, R.; Mantovani, S.; Panaccione, L.; Pizzicaroli, G. // Review of Scientific Instruments;Feb1989, Vol. 60 Issue 2, p237 

    In this paper we describe the bent crystal spectrometer of the Johann type built for the JET tokamak. This high resolution (λ/Δλ∼20 000) instrument is characterized by a very long focal length (25 m) allowing the crystal and the position sensitive detector to be placed outside the...

  • E parallel B canted detector neutral-particle spectrometer. Armentrout, C. J.; Bramson, G.; Evanko, R. // Review of Scientific Instruments;Nov85, Vol. 56 Issue 11, p2101 

    A multichannel, mass-discriminating, neutral-particle spectrometer using parallel E and B analyzer fields has been operational on the Doublet III tokamak. The device records 60 energy channels each of hydrogen and deuterium, simultaneously, during a shot with a dynamic range in energy of greater...

  • X-ray line diagnostics on the Tore Supra tokamak. Platz, P.; Margerit, Y.; Artaud, J.-F.; Mattioli, M.; Moulin, B. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p308 

    Describes the design and properties of a Johann-type spectrometer for the Tore Supra tokamak. Main components of the spectrometer; X-ray line spectroscopy on Tore Supra; Absolute calibration; Measurements of precise wavelengths; Impurity densities obtained.

  • Bragg rotor spectrometer for the JET tokamak (abstract). Barnsley, R.; Patel, A.; Peacock, N. J.; Smith, R. T. C. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5022 

    A Bragg rotor spectrometer uses diffractors ranging from LiF (420) (2d=0.18 nm) to a multilayer mirror (Ni-C 2d=11.7 nm). The extension to longer wavelengths is particularly useful at JET, where radiated power and Z[sub eff] are usually dominated by light impurities such as Be and C, whose H-...

  • Escaping charged fusion product spectrometer on Alcator C-Mod. Lo, Daniel H.; Boivin, Rejean L.; Petrasso, Richard D. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p345 

    Designs a spectrometer for studying escaping charged fusion on the Alcator C-Mod tokamak. Evaluation of the effectiveness of helium minority heating through the broadened spectrum of unconfined protons.

  • Radiated power measurement during the thermal quench phase of a density limit disruption. Hollmann, E. M.; Gray, D. S.; Whyte, D. G.; Pigarov, A. Yu.; Krasheninnikov, S. I.; Boedo, J. A.; Humphreys, D. A. // Physics of Plasmas;Jul2003, Vol. 10 Issue 7, p2863 

    Radiated power measurements taken during the thermal quench of a density limit disruption in the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] demonstrate that ten times more power is radiated from the main chamber than is deposited into the divertor floor. This contrasts with the...

  • The DIII-D E||B charge exchange diagnostic. Heidbrink, W. W. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1679 

    One of the neutral-particle spectrometers used on the Doublet III tokamak has been improved and modified for use as an active charge exchange diagnostic on the DIII-D tokamak. The spectrometer employs a He stripping cell, parallel E and B analyzer fields, and a microchannelplate detector with 60...

  • Time of flight electron spectrometry on TIR using natural diamond detector. Krasilnikov, A. V.; Makarov, K. N.; Rastyagaev, I. N.; Satov, Yu. A.; Smakovskiy, Yu. B.; Alekseyev, A. G.; Amosov, V. N. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1258 

    Natural diamond detectors (NDDs) being developed for the spectrometric applications in tokamak fusion plasma experiments, have been used also for fast x-ray flux measurements and time-of-flight (TOF) electron spectrometry in laser beam-target interaction experiments on the CO[sub 2] laser...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics