TITLE

Hard x-ray sputtered-sliced phase zone plates

AUTHOR(S)
Bionta, Richard M.; Skulina, Kenneth M.
PUB. DATE
February 1994
SOURCE
Applied Physics Letters;2/21/1994, Vol. 64 Issue 8, p945
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Examines the use of sputtered-sliced zone plates as optical elements for high energy x-ray systems in the United States. Importance of zone plate performance to process imperfections and testing conditions; Applicability of the technique for arbitrary lens slicing; Comparison between experiment results and Monte Carlo simulation.
ACCESSION #
4266358

 

Related Articles

  • Photon sieve for X-rays. Lerner, Eric J. // Industrial Physicist;Apr/May2002, Vol. 8 Issue 2, p10 

    Focuses on photon sieves for X-rays. Difficulty of fabrication of X-rays; Use of Fresnel zone plates; Development of an alternative plate from the efforts of researchers of the University of Kiel and the University of Hamburg.

  • High numerical aperture zone plates using high orders of diffraction. Hambach, Dirk // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p662 

    The implementation of laboratory X-ray microscopes with isotropic sources like laser generated plasmas requires condenser elements which collect photons from large solid angles, match the aperture of the micro zone plate objective to insure high spatial frequency transfer and allow to work at...

  • Toward high resolution and high efficiency Zone Plate for X-ray applications. Di Fabrizio, Enzo; Romanato, Filippo; Gentili, Massimo // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p635 

    High resolution and high efficiency Zone Plate for X-rays in the energy range of 300 eV and 12 KeV fabricated by means of electron beam and X-ray lithography are presented. Regarding the high resolution issue gold zone plate with 70 nm resolution and thickness of 0.4 μm are shown. When the...

  • Fabrication and characterization of Tungsten zone plates for multi KeV X-rays. Charalambous, P. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p625 

    Tungsten is a material well suited for the fabrication of diffractive optics intended for use at high (multi KeV) X-ray energies. It is however a particularly difficult material to deposit, especially when relatively thick (<500 nm) films on thin membranes are needed. In such a case, deposition...

  • Phase zone plates for hard X-ray focusing. Vladimirsky, Yuli // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p615 

    The major obstacle for constructing a deep UV or X-ray lens is the low refraction and high absorption of materials in this region. Only a few Fresnel zones are utilized, so the diameter of an X-ray lens is of the order few microns, and the resolution is hardly better than that of a pinhole. The...

  • Fabrication of thick zone plates for multi-kilovolt X-rays. Du¨vel, A.; Rudolph, D.; Schmahl, G. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p607 

    Phase zone plates for multi-kilovolt X-rays with an outermost zone width of 16.9-30 nm and aspect ratios up to 177 were generated by a sputtered-sliced technology. The generated lenses of alternating Ni80Cr20 and SiO[sub 2] consist of 188-365 layers on borosilicate glass wires and were polished...

  • Imaging hard X-ray microscopy with a multilayer Fresnel zone plate. Awaji, Mitsuhiro; Suzuki, Yoshio; Takeuchi, Akihisa; Kamijo, Nagao; Tamura, Shigeharu; Yasumoto, Masato; Kohmura, Yoshiki // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p545 

    Preliminary experiments by use of a multilayer Fresnel zone plate (FZP) have been performed for bright-field imaging at 25kev hard X-rays. The #1500 gold mesh was selected as a test specimen. The mesh structure has been successfully observed in the bright-field images.

  • X-ray microbeam with sputtered-sliced Fresnel zone plate at Spring-8 undulator beamline. Suzuki, Y.; Awaji, M.; Kohmura, Y.; Takeuchi, A.; Kamijo, N.; Tamura, S.; Handa, K. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p535 

    Hard X-ray microbeam with sputtered-sliced Fresnel zone plate has been tested at SPring-8 undulator beam line. Focusing properties are evaluated in X-ray wavelength regions of 0.15-1.6 Å. The measured focal beam size is about 0.6 μm at an X-ray wavelength of 1.4 Å, and 0.7 μm at...

  • Development of zone plates with a blazed profile for hard x-ray applications. Yun, W.; Lai, B.; Krasnoperova, A.A.; Di Fabrizio, E.; Cai, C.; Cerrina, F.; Chen, Z.; Gentili, M.; Gluskin, E. // Review of Scientific Instruments;Sep99, Vol. 70 Issue 9, p3537 

    Fabricates and characterizes a linear and circular zone plate with a blazed zone profile using synchrotron x rays. Improved performance in compared with a zone plate with a square profile; Experimental characterization; Special applications.