TITLE

Assessment of implantation damage by backscatter Kikuchi diffraction in the scanning electron

AUTHOR(S)
Troost, K.Z.
PUB. DATE
August 1993
SOURCE
Applied Physics Letters;8/16/1993, Vol. 63 Issue 7, p958
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Examines the effectiveness of backscatter Kikuchi diffraction (BKD) method in the scanning electron microscope to investigate surface damage caused by ion implantation of silicon(100) materials. Use of standard image processing operations; Sensitivity of the technique in measuring the surface profile; Comparison between BKD and Rutherford backscattering spectrometry.
ACCESSION #
4258251

 

Related Articles

  • Effects of microstructure on the formation, shape, and motion of voids during electromigration in passivated copper interconnects. Choi, Z-S.; Mönig, R.; Thompson, C. V. // Journal of Materials Research;Feb2008, Vol. 23 Issue 2, p9 

    In situ scanning electron microscope observations have been performed on passivated damascene Cu interconnect segments of different widths during accelerated electromigration tests. In some cases, voids form and grow at the cathode. However, an alternative failure mode is also observed, during...

  • Influence of Substrate on High-Temperature Behavior of Copper Film Studied In Situ by Electron Backscatter Diffraction. Mirpuri, Kabirkumar J.; Szpunar, Jerzy A. // Journal of Electronic Materials;Dec2005, Vol. 34 Issue 12, p1509 

    Change in the in-plane orientation of (111) grains in the copper film was studied in situ by electron backscatter diffraction (EBSD) during its thermal treatment inside the scanning electron microscope (SEM). Two separate investigations were carried out each at different locations of the film....

  • Microscale elastic-strain determination by backscatter Kikuchi diffraction in the scanning.... Troost, K.Z.; van der Sluis, P.; Gravesteijn, D.J. // Applied Physics Letters;3/8/1993, Vol. 62 Issue 10, p1110 

    Examines the microscale elastic-strain determination using a backscatter Kikuchi diffraction (BKD) in the scanning electron microscope. Significance of the higher-order Laue zone in determining indium layer strain; Effect of gnomonic projection on Kikuchi bands; Application of cross-correlation...

  • Microwave Sintering of Electroless Ni Plated WC Powders. Erol, Ayhan; Yonetken, Ahmet // Gazi University Journal of Science;Jul2009, Vol. 22 Issue 3, p227 

    Nickel matrix reinforced with WC has been manufactured by microwave sintering at various temperatures. A uniform nickel layer on WC powders was deposited prior to sintering using electroless plating technique, allowing close surface contact than can be achieved using conventional methods such as...

  • Orientation Imaging Microscopy for the Transmission Electron Microscope. Dingley, David J. // Microchimica Acta;Sep2006, Vol. 155 Issue 1/2, p19 

    The resolution limit of Orientation Imaging Microscopy in the Scanning Electron Microscope is between 20 nA and 80 nA depending on the basic resolution/beam current performance of the SEM, the sample atomic number and the level of residual strain within it. The newer technique of orientation...

  • GRAIN BOUNDARY DETECTION OF THE CRYSTALS USING CANNY EDGE DETECTION. Varadhalakshmi, M.; Muruganand, S.; Chinnasamy, G. // International Journal of Advanced Biological Research;2012, Vol. 2 Issue 2, p271 

    Microstructure of the materials is characterized by employing Scanning Electron Microscope (SEM). Image processing algorithm is implemented to detect the grain boundary of the crystal using SEM images. For this Canny edge detection is used to segment the boundaries of the crystal. In this method...

  • Instrument combines SEM and fatigue testing. Romero, Adriana // Advanced Materials & Processes;Aug2007, Vol. 165 Issue 8, p55 

    This article examines improvement in the design of scanning electron microscopes (SEM). The introduction of the field emission gun and high quality lenses have enhanced the resolution standard. In addition, quality and capabilities of analytical techniques such as Energy Dispersive Spectrometry...

  • Noncontact thermal-wave imaging of subsurface structure with infrared detection. Ermert, H.; Dacol, F. H.; Melcher, R. L.; Baumann, T. // Applied Physics Letters;1984, Vol. 44 Issue 12, p1136 

    A noncontact thermal imaging system using infrared detection is described. The system uses a chopped and scanned electron beam as a heat source to produce a temperature pattern on the surface of the sample. The resulting thermal radiation is detected and used for numerical image reconstruction...

  • UTILIZING EBSD TO VALIDATE AND UNDERSTAND NDE TECHNIQUES. Essex, S. D.; Potter, M. D. G.; Vann, R.; Dixon, S // AIP Conference Proceedings;3/3/2009, Vol. 1096 Issue 1, p1224 

    Electron Backscatter Diffraction (EBSD) is a destructive, surface-specific technique that measures accurately crystallographic orientations within a scanning electron microscope (SEM). From this data we can infer elastic properties, calculate levels of stress and measure microstructural...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.