TITLE

Synthesis and properties of a-axis and b-axis oriented GdBa[sub 2]Cu[sub 3]O[sub 7-delta] high

AUTHOR(S)
Nakamura, O.; Guimpel, J.
PUB. DATE
November 1992
SOURCE
Applied Physics Letters;11/23/1992, Vol. 61 Issue 21, p2598
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Examines the properties of grown a-axis and b-axis oriented GdBa[sub 2]Cu[sub 3]O[sub 7-delta] thin films. Use of secondary thermocouple in calibrating estimated substrate temperature; Relevance of low substrate temperature in YBCO films; Effect of T[sub s] on a-axis and c-axis growth.
ACCESSION #
4250603

 

Related Articles

  • The fabrication of thin-film thermocouples for determining the temperature and thermal conductivity within a flexible material. Rimai, D. S.; Anne, R.; Bowen, R. C. // Review of Scientific Instruments;Jun93, Vol. 64 Issue 6, p1601 

    Thin-film thermocouples were produced on flexible polymeric and paper substrates using evaporation techniques. These devices were found to be simple to produce, durable, and to have good temperature sensitivity. These devices allow the temperature and thermal conductivity of thin coatings to be...

  • High-temperature thin-film Pt–Ir thermocouple with fast time response. Tong, H. M.; Arjavalingam, G.; Haynes, R. D.; Hyer, G. N.; Ritsko, J. J. // Review of Scientific Instruments;May87, Vol. 58 Issue 5, p875 

    We have developed a thin-film Pt–Ir thermocouple which exhibits bulklike thermoelectric behavior up to 790 °C, the highest temperature observed with thin-film pure-element thermocouples. Using a Q-switched Nd:YAG laser and a signal averaging oscilloscope, its thermal response time was...

  • Calibration of micron-size thermocouples for measurements of surface temperature. Schreck, Erhard; Hiller, Bernhard; Singh, Gurinder P. // Review of Scientific Instruments;Jan1993, Vol. 64 Issue 1, p218 

    Imbedded thin-film thermocouples can be used for the measurement of transient surface temperatures with high spatial resolution and sensitivity. To minimize environmental effects it is desirable to have close proximity between the reference junction and the sensor junction. In this article, we...

  • Effects of Wafer Emissivity on Rapid Thermal Processing Temperature Measurement. Chen, D. H.; Dewitt, D. P.; Tsai, B. K.; Kreider, K. G.; Kimes, W. A. // AIP Conference Proceedings;2003, Vol. 684 Issue 1, p735 

    Lightpipe radiation thermometers (LPRTs) are widely used to measure wafer temperatures in rapid thermal processing (RTP) tools. To use blackbody-calibrated LPRTs to infer the wafer temperature, it is necessary to build a model to predict the effective emissivity accounting for the wafer and...

  • Scanning thermal microscopy of carbon nanotubes using batch-fabricated probes. Shi, Li; Li Shi; Plyasunov, Sergei; Bachtold, Adrian; McEuen, Paul L.; Majumdar, Arunava // Applied Physics Letters;12/25/2000, Vol. 77 Issue 26 

    We have designed and batch-fabricated thin-film thermocouple cantilever probes for scanning thermal microscopy (SThM). Here, we report the use of these probes for imaging the phonon temperature distribution of electrically heated carbon-nanotube (CN) circuits. The SThM images reveal possible...

  • Anodic vacuum arc developed nanocrystalline Cu–Ni and Fe–Ni thin film thermocouples. Mukherjee, S. K.; Sinha, M. K.; Pathak, B.; Rout, S. K.; Barhai, P. K. // Journal of Applied Physics;Dec2009, Vol. 106 Issue 11, p113717-1 

    This paper deals with the development of nanocrystalline Cu–Ni and Fe–Ni thin film thermocouples (TFTCs) by using ion-assisted anodic vacuum arc deposition technique. The crystallographic structure and surface morphology of individual layer films have been studied by x-ray...

  • Surface temperature rise in multilayer solids induced by a focused laser beam. Kodas, Toivo T.; Baum, Thomas H.; Comita, Paul B. // Journal of Applied Physics;4/15/1987, Vol. 61 Issue 8, p2749 

    Determines surface temperatures of a laser-heated structure consisting of intersecting gold and nickel lines on a silicon substrate with a silicon dioxide surface layer. Development of methods to alter the physical or chemical properties of materials with highly localized temperature increases...

  • Thermal sensors for investigation of heat transfer in scanning probe microscopy. Xu, J. B.; Läuger, K.; Dransfeld, K.; Wilson, I. H. // Review of Scientific Instruments;Jul1994, Vol. 65 Issue 7, p2262 

    Planar thermocouples designed for investigation of heat transfer in scanning tunneling microscopy and scanning thermal microscopy are described. The limit of sensitivity to local thermal power can be as small as 10 nW. The devices are based on two different thin films formed as a cross on a thin...

  • 6 Key Trends in Temperature Technology. Yoder, Jesse // Flow Control;Jun2007, Vol. 13 Issue 6, p6 

    The article focuses on the key trends in the process temperature market. It is noted that there is a shift in applications from thermocouples to resistance temperature detectors (RTD). In RTD, demand is increasing for thin-film devices as compare to wire-wound RTDs. It is mentioned that the...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics