ABSTRACT
Demonstrates efficient operation of a broadly tunable picosecond optical parametric oscillator pumped by a diode-laser-pumped solid-state-laser. Characterization of nonlinear crystal LiB[sub 3]O[sub 5]; Possession of noncritical phase-matching capability and temperature tunability; Determination of the tuning range and spectral characteristics using a monochromator.
ACCESSION #
4241129

 

Related Articles

  • Development of an imaging vacuum-ultraviolet monochromator in the normal incidence region. Koog, J.; Iwasaki, K.; Sato, K.; Hamada, Y.; Toi, K.; JIPP T-IIU Group // Review of Scientific Instruments;Nov96, Vol. 67 Issue 11, p3871 

    Presents a study that developed an imaging vacuum-ultraviolet monochromator to provide the space-resolved impurity line emissions from magnetically confined plasmas. Minor modifications of a commercial normal incidence monochromator; Pinhole entrance slit; Microchannel plate detector.

  • The influence of Hg(63P2) population on emission processes in a low-pressure mercury-argon discharge. Maleki, L.; Blasenheim, B. J.; Janik, G. R. // Journal of Applied Physics;9/15/1990, Vol. 68 Issue 6, p2661 

    Examines the influence of the mercury population on discharge emission to probe a low-pressure mercury-argon discharge. Use of laser spectroscopy; Role of metastables in the excitation process of the mercury ions; Measurement of discharge emission by a monochromator.

  • Inspection of a Spherical Triple VLS-Grating for Self-Seeding of FLASH at DESY. Siewert, Frank; Lammert, Heiner; Reichardt, Gerd; Hahn, Ulrich; Treusch, Rolf; Reininger, Ruben // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p667 

    To take benefit from the improved brilliance of the laser-like source, proposed beamlines at Free Electron Lasers (FEL) require optical elements of excellent precision, characterised by slope errors beyond the state of the art limit of 0.5μrad rms for plane and spherical shape. Part of the...

  • Time-resolved measurement of hole sweepout in a GaAs photoconductor. Von Lehmen, A.; Ballantyne, J. M. // Applied Physics Letters;1984, Vol. 44 Issue 1, p87 

    A nonlinear luminescence technique is used to measure hole sweepout in a GaAs photoconductor at room temperature. The measured sweepout time for an applied field of 20 kV/cm corresponds to an average hole velocity of 2.0×106 cm/s. A simple model for extracting the photoexcited population...

  • Laser-induced breakdown spectra of Zn2 molecule in the violet region. Singh, Subhash C.; Ojha, K. S.; Gopal, R. // Pramana: Journal of Physics;Sep2006, Vol. 67 Issue 3, p519 

    Laser-induced breakdown spectrum has been recorded in the region of 380 455 nm using second harmonics of Nd:YAG laser, computer-controlled TRIAX 320 M monochromator with a reciprocal linear dispersion 2.64 nm/mm fitted with ICCD detector. The spectrum consists of 108 bands, which are classified...

  • Selection of a single femtosecond high-order harmonic using a zone plate based monochromator. Gaudin, J.; Rehbein, S.; Guttmann, P.; Godé, S.; Schneider, G.; Wernet, Ph.; Eberhardt, W. // Journal of Applied Physics;Aug2008, Vol. 104 Issue 3, p033112 

    We report the use of zone plate optics as a monochromator for the spectral selection of a single high-order harmonic of a femtosecond laser generated in a rare gas medium. We show that this is a convenient way of monochromatizing the vacuum ultraviolet (VUV) pulses in the photon energy range...

  • Enhancement of Ne-like Ar 46.9 nm laser output by mixing appropriate He ratio at low pressure. Zhao, Y.; Xie, Y.; Wang, Q.; Liu, T. // European Physical Journal D -- Atoms, Molecules, Clusters & Opti;Mar2009, Vol. 49 Issue 3, p379 

    With pure Ar and gaseous mixtures of Ar-He, the laser spike of Ne-like Ar 46.9 nm pumped by capillary discharge is measured with XRD (X-ray diode) at low pressure. We observe the effects of the Ar pressure and the He ratio on the amplitude of laser pulse. Compared with the laser spike of pure...

  • X-ray Multilayer Optics for Indus Synchrotrons Application. Nayak, Maheswar; Pradhan, P. C.; Lodha, G. S. // AIP Conference Proceedings;2015, Vol. 1665, p1 

    We present the state-of-the-art X-ray multilayer optics fabrication facilities at Indus synchrotrons complex. The facilities are regularly used for fabrication of high quality x-ray multilayer structures. The results on two representative materials combination of Mo/Si and W/B4C are presented....

  • Soft x-ray beamline BL7A at the UVSOR. Murata, T.; Matsukawa, T.; Naoé, S.; Horigome, T.; Matsudo, O.; Watanabe, M. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p1309 

    A vacuum-compatible double-crystal monochromator with constant exit-beam height has been installed and operated for several years at beamline BL7A at the UVSOR facility at the Institute for Molecular Science, Okazaki, Japan, The beamline is used both for the photons from a normal bending-magnet...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics