TITLE

Single-polarity charge sensing in ionization detectors using coplanar electrodes

AUTHOR(S)
Luke, P.N.
PUB. DATE
November 1994
SOURCE
Applied Physics Letters;11/28/1994, Vol. 65 Issue 22, p2884
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a method to sense the collection of single-polarity charge carriers in ionization detectors. Significance of coplanar electrodes to emulate functions of Frisch grids; Manifestation of the method in relation to obtain good energy resolution; Demonstration of the method effectiveness by using cadmium zinc telluride detector.
ACCESSION #
4233226

 

Related Articles

  • The Advantages of Cold-Cathode Vacuum Gauges. Bopp, Eric // R&D Magazine;Oct2000, Vol. 42 Issue 10, p35 

    Highlights the uses of cold-cathode ionization sensor in vacuum gauges. Advantages of the sensor; Components of the sensor; How the sensor functions.

  • GaAs takes on weapons-detection role. Schweber, Bill // EDN;9/26/2002, Vol. 47 Issue 21, p26 

    Reports the development of sensors using gallium arsenide doped with boron. Production of cascade of charged particles; Failure of silicon-based sensor to degrade on high radiation fields; Factors influencing the ionization of gas.

  • Pulse-shape analysis of ionization events in low-temperature germanium detectors. Broniatowski, A.; Juillard, A.; Berge´, L.; Dumoulin, L. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p521 

    Pulse-shape analysis, supported by numerical simulations, provides a powerful tool to investigate ionization phenomena in low-temperature semiconducting detectors for the Edelweiss darkmatter experiment. We present a first application of these methods to characterize the surface, as compared...

  • Charge collection and electrode structures in ionization and phonon based dark matter detectors. Shutt, T.; Kesden, M.; Golwala, S.; Emes, J.; Hellmig, J.; Sadoulet, B.; Young, B. A. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p513 

    We report on progress in our understanding of the physics of of implanted contacts, amorphous layer structures and Schottky contacts on detectors based on the simultaneous ionization and phonon based at 20 mK. Loss of charge for events near the contacts limits the capabilities of these detectors...

  • Position dependence in the CDMS II ZIP detectors. Mandic, V.; Rau, W.; Akerib, D.; Brink, P.; Cabrera, B.; Castle, J. P.; Chang, C.; Crisler, M. B.; Driscoll, D.; Emes, J.; Gaitskell, R. J.; Hellmig, J.; Huber, M. E.; Kamat, S.; Martinis, J. M.; Meunier, P.; Perera, T. A.; Perillo-Issac, M.; Saab, T.; Sadoulet, B. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p509 

    The Ge and Si detectors developed by the Cryogenic Dark Matter Search (CDMS) II experiment rely on the simultaneous detection of athermal phonons and ionization produced by interactions in the crystal. The athermal phonons provide both the total energy deposited in an interaction and the...

  • High efficiency molecular-beam ionization detector with short ionization region. Kuhnke, K.; Kern, K.; David, R.; Comsa, G. // Review of Scientific Instruments;Nov94, Vol. 65 Issue 11, p3458 

    A mass selective electron-impact ionization detector for use in energy resolved thermal He scattering experiments is presented. The detector combines a short effective ionization region (approximately 3 mm FWHM) with a high detection efficiency of 10[sup -5] at 2 mA electron emission. An...

  • Pulsed, high-current, in-line reversal electron attachment detector. Bernius, Mark T.; Chutjian, Ara // Journal of Applied Physics;10/1/1989, Vol. 66 Issue 7, p2783 

    Describes a pulsed, high-current, in-line reversal electron attachment ionizer/detector. Function of the ionizer; Higher-energy behavior with regard to molecular attachment and ionization; Theoretical background for electron attachment in molecular systems.

  • A Liquid-Argon Ionization Detector for the Study of Double β Decay. Ashitkov, V. D.; Barabash, A. S.; Belogurov, S. G.; Carugno, G.; Konovalov, S. I.; Massera, F.; Puglierin, G.; Saakyan, R. R.; Stekhanov, V. N.; Umatov, V. I. // Instruments & Experimental Techniques;Mar/Apr2003, Vol. 46 Issue 2, p153 

    A multisection liquid-argon ionization detector has been developed by the DBA collaboration to study double β decay of 100Mo. The experiment has been carried out in the Gran Sasso underground laboratory in Italy. The detector design and main characteristics are described. The limits on the...

  • Electrical properties of Hg[sub 1-x]Mn[sub x]Te-based photodiodes. Kosyachenko, L. A.; Rarenko, I. M.; Bodnaruk, O. A.; Weiguo, Sun // Semiconductors;Dec99, Vol. 33 Issue 12, p1293 

    Electrical properties (at 80 K) of p - n junctions fabricated by ion milling of p-type Hg[sub 0.91]Mn[sub 0.09]Te are analyzed. The forward current-voltage characteristics at low biases is shown to be governed by carrier recombination in the space charge region and at higher biases its voltage...