TITLE

Dc SQUID magnetometers from single layers of YBa[sub 2]Cu[sub 3]O[sub 7-x]

AUTHOR(S)
Koelle, D.; Miklich, A.H.
PUB. DATE
October 1993
SOURCE
Applied Physics Letters;10/18/1993, Vol. 63 Issue 16, p2271
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Fabricates the direct current superconducting quantum interference device (SQUID) magnetometers from YBa[sub 2]Cu[sub 3]O[sub 7-x] thin films. Use of flux modulation to measure the magnetometer noise; Relationship between magnetic field sensitivity and hole size; Effect of reducing SQUID inductance on magnetic field resolution.
ACCESSION #
4233046

 

Related Articles

  • Ultrahigh frequency thin film rf-SQUID magnetometer with a cryogenic preamplifier employing a high-electron-mobility transistor. Cavalleri, A.; Cerdonio, M.; Fontana, G.; Jung, G.; Macchietto, R.; Mezzena, R.; Vitale, S.; Zendri, J. P. // Review of Scientific Instruments;Nov92, Vol. 63 Issue 11, p5403 

    Ultrahigh frequency rf-SQUID magnetometer employing a cryogenic preamplifier and a commercially available thin film rf-SQUID sensor have been designed, manufactured, and tested. The system has been operated at 316 MHz, which is the maximum pump frequency accepted by the thin film sensor. The...

  • Low-noise YBa[sub 2]Cu[sub 3]O[sub 7] rf SQUID magnetometer. Yi Zhang; Muck, H.-M. // Applied Physics Letters;2/3/1992, Vol. 60 Issue 5, p645 

    Develops a low-noise radiofrequency superconducting quantum interferometer device (rf SQUID) magnetometer. Use of an epitaxial YBa[sub 2]Cu[sub 3]O[sub 7] thin film pulsed-laser; Characterization of the device with step-edge junctions immersed in liquid nitrogen gas; Determination of transfer...

  • Ultrahigh vacuum compatible superconducting quantum interference device magnetometer system for... Spagna, S.; Sager, R.E.; Maple, M.B. // Review of Scientific Instruments;Dec1995, Vol. 66 Issue 12, p5570 

    Describes an ultrahigh vacuum compatible superconducting quantum interference device magnetometer system for investigations of surface, interface and thin film magnetism. Apparatus overview; Schematic representation of the vacuum system; Sample lock entry; Principle of operations.

  • Key elements for a sensitive 77 K direct current superconducting quantum interference device.... Lee, L.P.; Teepe, M. // Applied Physics Letters;5/29/1995, Vol. 66 Issue 22, p3058 

    Demonstrates the operation of direct current superconducting quantum interference device (SQUID) magnetometers. Advantages of single layer devices; Acceptance of high-temperature semiconductor thin-film technology; Discussion of the key elements of achieving good performance of SQUID.

  • Magnetic properties of molecular-beam epitaxial grown (100) iron films. Lottis, D. K.; Florczak, J.; Dahlberg, E. Dan; Batra, S.; Wowchak, A. M.; Cohen, P. I. // Journal of Applied Physics;4/15/1988, Vol. 63 Issue 8, p3662 

    Deals with a study that focused on the magnetic properties of epitaxial iron films. Process of growing the iron films; Factors examined with the use of a superconducting quantum interference device magnetometer; Measurement of the coercivity of the films; Step taken to better understand the...

  • Integrated YBa[sub 2]Cu[sub 3]O[sub 7-x] magnetometer for biomagnetic measurements. Drung, D.; Ludwig, F. // Applied Physics Letters;3/4/1996, Vol. 68 Issue 10, p1421 

    Fabricates direct current superconducting quantum interference device (SQUID) magnetometer using YBa[sub 2]Cu[sub 3]O[sub 7-x] (YBCO)-SrTiO[sub 3]-YBCO multilayer process. Insertion of the SQUID robe in biomagnetic dewar; Observation of biomagnetic measurements for integrated magnetometer;...

  • Transfer function and noise properties of YBa[sub 2]Cu[sub 3]O[sub 7-δ] direct-current superconducting-quantum-interference-device magnetometers with resistively shunted inductances. Kahlmann, F.; Booij, W. E.; Booij, W.E.; Blamire, M. G.; Blamire, M.G.; McBrien, P. F.; McBrien, P.F.; Tarte, E. J.; Tarte, E.J.; Peng, N. H.; Peng, N.H.; Jeynes, C.; Romans, E. J.; Romans, E.J.; Pegrum, C. M.; Pegrum, C.M. // Applied Physics Letters;7/24/2000, Vol. 77 Issue 4 

    Studies the transfer function and noise properties of direct-current superconducting-quantum-interference-device (SQUID) magnetometers with resistively shunted inductances. Maximum voltage modulation depth and calculated values based on the theoretical predictions by Enpuku, et. al.; White...

  • Low 1/f flux noise in sputtered YBa2Cu3O7-x bicrystal dc-superconducting quantum interference... Sarnelli, E.; Camerlingo, C.; Russo, M.; Torrioli, G.; Castellano, M. G. // Journal of Applied Physics;10/15/1997, Vol. 82 Issue 8, p3922 

    Analyzes the YBa2Cu3O7-x bicrystal dc-superconducting quantum interference devices (SQUID) and single layer magnetometers working at 77 K. Different geometrical configurations of SQUID characteristic parameters; Comparison between experimental H values and calculated ones by using Eq; Behavior...

  • High performance dc SQUID magnetometers with single layer YBa[sub 2]Cu[sub 3]O[sub 7-x] flux.... Koelle, D.; Miklich, A.H. // Applied Physics Letters;12/27/1993, Vol. 63 Issue 26, p3630 

    Details the fabrication of direct current (dc) superconducting quantum interference device (SQUID) magnetometers with single film YBa[sub 2]Cu[sub 3]O[sub 7-x] flux transformers. Attachment of the transformer to a loop directly coupled to a dc SQUID; Values of the lowest magnetic field noise...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.