The Squeaking Hip: A Phenomenon of Ceramic-on-Ceramic Total Hip Arthroplasty

Jarrett, Christopher A.; Ranawat, Amar S.; Bruzzone, Matteo; Blum, Yossef C.; Rodriguez, Jose A.; Ranawat, Chitranjan S.
June 2009
Journal of Bone & Joint Surgery, American Volume;Jun2009, Vol. 91-A Issue 6, p1344
Academic Journal
Background: Early reports on modern ceramic-on-ceramic total hip replacements have demonstrated excellent clinical and radiographic results with few cases of catastrophic failure, which, in the case of earlier designs, often had been caused by implant fracture. Several reports, however, have noted the presence of audible squeaking. The purpose of the present study was to determine the incidence of squeaking in association with the use of this bearing couple. Methods: During the period from March 2003 to May 2005, three surgeons performed 159 total hip arthroplasties in 143 patients with use of a ceramic-on-ceramic bearing. One hundred and forty-nine hips (131 patients) were available for review after at least one year of follow-up. These patients were followed prospectively with use of the modified Hospital for Special Surgery hip score and a patient-administered questionnaire. Additionally, a control group of sixty hips (forty-eight patients) with a metal-on-polyethylene bearing was matched to the ceramic group on the basis of age, sex, and body mass index to compare the incidence of squeaking and other noises. Radiographic evaluations were performed according to previously established criteria. Results: Fourteen (10.7%) of 131 patients described an audible squeak during normal activities. However, squeaking was reprodudible clinically in only four patients, and only one patient complained of squeaking before being presented with the questionnaire. The average Hospital for Special Surgery score improved from 19.8 preoperatively to 38.4 at the time of the latest follow-up, indicating excellent clinical results. Ninety-five percent of the patients had a satisfaction score of ≥8 of 10. Three hips dislocated. One of those three hips squeaked and was revised because of recurrent dislocations. One patient was considering revision because of squeaking. In the matched metal-on-polyethylene cohort, there were no cases of squeaking. Conclusions: The squeaking hip is a phenomenon that is unique to total hip replacements with hard-on-hard bearings. The incidence of squeaking in association with ceramic-on-ceramic bearings may be higher than previously reported as <1% of the patients in the present study reported this finding before being queried. The causes and implications of squeaking are yet to be determined. The use of hard-on-hard bearings offers many advantages in terms of wear reduction, especially for young and active patients. Nonetheless, patients considering ceramic-on-ceramic bearings should be counseled with regard to this phenomenon.


Related Articles

  • Impact of Hospital Volume on the Economic Value of Computer Navigation for Total Knee Replacement. Slover, James D.; Tosteson, Anna N. A.; Bozic, Kevin J.; Rubash, Harry E.; Malchau, Henrik // Journal of Bone & Joint Surgery, American Volume;Jul2008, Vol. 90-A Issue 7, p1492 

    Background: An aim of the use of computer navigation is to reduce rates of revisions of total knee replacements by improving the alignment achieved at the surgery. However, the decision to adopt this technology may be difficult for some centers, especially low-volume centers, where the cost of...

  • Effect of limb rotation on radiographic alignment in total knee arthroplasties. Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven // Archives of Orthopaedic & Trauma Surgery;Apr2010, Vol. 130 Issue 4, p451 

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic...

  • Long-Term Changes of the Nonresurfaced Patella After Total Knee Arthroplasty. Hsin-Nung Shin; Lih-Yuan Shih; Yon-Cheong Wong; Wen-Wei Hsu, Robert // Journal of Bone & Joint Surgery, American Volume;May2004, Vol. 86-A Issue 5, p935 

    The most common complications of total knee arthroplasty involve the patellofemoral joint. However, the long-term fate of the nonresurfaced patella after total knee arthroplasty has seldom been reported. The purpose of this study was to evaluate the long-term changes of the nonresurfaced patella...

  • Lengthening of the iliotibial band by femoral detachment and multiple puncture: A cadaver study. Zenz, P.; Huber, M.; Obenaus, C.H.; Schwägerl, W. // Archives of Orthopaedic & Trauma Surgery;Aug2002, Vol. 122 Issue 8, p429 

    Background. Lengthening of the iliotibial band by various methods such as distal detachment, Z-plasty, or multiple puncture are common procedures for balancing the contracted valgus knee in total knee arthroplasty. This study was performed to measure the lengthening effect of multiple puncture...

  • Midvastus approach in total knee arthroplasty: a randomized, double-blinded study on early rehabilitation. Bäthis, Holger; Perlick, Lars; Blum, Christian; Lüring, Christian; Perlick, Carsten; Grifka, Joachim // Knee Surgery, Sports Traumatology, Arthroscopy;Oct2005, Vol. 13 Issue 7, p545 

    The medial parapatellar approach has become the standard technique in total knee arthroplasty (TKA). However, recent studies have reported superior results regarding functional recovery when using the midvastus approach. It was the aim of this study to evaluate the early functional outcome of...

  • Failure at the Taper Lock of a Modular Stemmed Femoral Implant in Revision Knee Arthroplasty: A Report of Two Cases and a Retrieval Analysis. Issack, Paul S.; Cottrell, Jocelyn M.; Delgado, Samuel; Wright, Timothy M.; Sculco, Thomas P.; Su, Edwin P. // Journal of Bone & Joint Surgery, American Volume;Oct2007, Vol. 89-A Issue 10, p2271 

    The article reports on two cases of patients who had failure in the male portion of the taper lock between the femoral component and the stem extension of the Optetrak stemmed constrained femoral implant in revision knee arthroplasty. Both cases underwent second revision arthroplasty, during...

  • Navigation of total knee arthroplasty: rotation of components and clinical results in a prospectively randomized study. Schmitt, Jan; Hauk, Carsten; Kienapfel, Heino; Pfeiffer, Michael; Efe, Turgay; Fuchs-Winkelmann, Susanne; Heyse, Thomas J. // BMC Musculoskeletal Disorders;2011, Vol. 12 Issue 1, p1 

    Background: Navigation was introduced into total knee arthroplasty (TKA) to improve accuracy of component position, function and survival of implants. This study was designed to assess the outcome of navigated TKA in comparison with conventional implantation with the focus on rotational...

  • THE FUNCTIONAL OUTCOMES OF TOTAL KNEE ARTHROPLASTY. Kane, Robert L.; Saleh, Khaled J.; Wilt, Timothy J.; Bershadsky, Boris // Journal of Bone & Joint Surgery, American Volume;Aug2005, Vol. 87-A Issue 8, p1719 

    Background: As an elective procedure, total knee arthroplasty is under scrutiny to evaluate its cost-effectiveness. In this review, we examined the available literature on total knee arthroplasty to assess the evidence regarding factors associated with better functional outcomes. Methods: A...

  • MANAGEMENT OF INFECTION AT THE SITE OF A TOTAL KNEE ARTHROPLASTY. Leone, James M.; Hanssen, Arlen D. // Journal of Bone & Joint Surgery, American Volume;Oct2005, Vol. 87-A Issue 10, p2336 

    This article discusses various issues related to the management of infection at the site of a total knee arthroplasty. While infection after total knee arthroplasty is a relatively infrequent complication, it can be devastating in terms of patient morbidity and institutional expenses. In an...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics