TITLE

Cryofibrination: did it really happen?

AUTHOR(S)
Luckraz, H.; Boolauky, D.; Mohangee, A.
PUB. DATE
January 2001
SOURCE
Perfusion;Jan2001, Vol. 16 Issue 1, p83
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Cryofibrin precipitation is a phenomenon which has only recently been described, although it might have been present since the advent of membraneoxygenators for cardiopulmonary bypass procedures. The deposition of the cold-reactive protein, cryofibrin, causes progressive occlusion of the heat-exchanger part of the cardiopulmonary circuit, thus leading to a high pressure-drop phenomenon. We describe our experience with a few cases in which the cryofibrination phenomenon developed while using the 'Avecor-Affinity Medtronic' membrane oxygenator.
ACCESSION #
4124505

 

Related Articles

  • The need for an organized ECMO-based respiratory program in Japan. Hashimoto, Satoru // Journal of Anesthesia;2012, Vol. 26 Issue 5, p647 

    The author suggests the importance of an organized extracorporeal membrane oxygenation (ECMO)-based respiratory program in Japan. He describes ECMO as an expanded clinical application of cardiopulmonary bypass introduced in the 1950s that allowed a longer period of support than other...

  • The relative safety of an oxygenator. Svenmarker, S.; Haggmark, S.; Jansson, E.; Lindholm, R.; Appelblad, M.; Aberg, T. // Perfusion;1997, Vol. 12 Issue 5, p289 

    Analysis of prospectively registered incidents related to cardiopulmonary bypass (CPB) was initiated to establish the incident rate for 10 different oxygenator brands employed over a seven-year period in 5000 clinical perfusions. A general safety index (SI) was defined as the number of recorded...

  • Editorial. Taylor, K. // Perfusion;1998, Vol. 13 Issue 3, p155 

    Editorial. Discusses on the ability of membrane oxygenators to handle and remove air. Quantification and localization of the air removal characteristics of membrane oxygenators; Analysis on the design and manufacture of cardiopulmonary bypass circuit components for neonatal and pediatric...

  • The incidence and cause of emergency oxygenator changeovers. Fisher, A.R. // Perfusion;1999, Vol. 14 Issue 3, p207 

    Emergency oxygenator changeover presents as an important potential hazard during cardiopulmonary bypass. In order to assess the frequency and possible causes of this event a retrospective survey was conducted of cardiothoracic units in the UK and Ireland. The survey was sent to these units in...

  • Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure. Groom, R. C.; Forest, R. J.; Cormack, J. E.; Niimi, K. S.; Morton, J. // Perfusion;Nov2002, Vol. 17 Issue 6, p447 

    We present here a technique to replace a failed oxygenator by inserting a second oxygenator in parallel (PRONTO) within the cardiopulmonary bypass (CPB) circuit. Oxygenator failure is a potential hazard that may result in patient injury or death. Although failures are rare, safety surveys...

  • Testing neonateinfant membrane oxygenators with the University of Texas neonatal pulsatile cardiopulmonary bypass system in vitro. √úndar, A.; Holland, M.C.; Howelton, R.V.; Benson, C.K.; Ybarra, J.R.; Miller, O.L.; Rossbach, M.M.; Runge, M.M.; Johnson, S.B.; Sako, E.Y.; Calhoon, J.H. // Perfusion;1998, Vol. 13 Issue 5, p346 

    Neurologic complications are already well documented after cardiopulmonary bypass (CPB) procedures in neonates and infants. Physiologic pulsatile flow CPB systems may be the alternative to the currently used steady-flow CPB circuits. In addition to the pulsatile pump, a membrane oxygenator...

  • The evolution of cardiopulmonary bypass: lessons to be learned. Edmunds Jr, L Henry // Perfusion;Jul2002, Vol. 17 Issue 4, p243 

    John Gibbon conceived cardiopulmonary bypass (CPB) and performed the first intracardiac repair using extracorporeal perfusion in 1953. This achievement stimulated rapid development of the knowledge base and equipment necessary for accurate diagnoses and successful intracardiac operations. In the...

  • Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators. de Somer, F.; Dierickx, P.; Dujardin, D.; Verdonck, P.; Nooten, G.V. // Perfusion;1998, Vol. 13 Issue 3, p157 

    At present, air handling of a membrane oxygenator is generally studied by using an ultrasonic sound bubble counter. However, this is not a quantitative method and it does not give any information on where air was entrapped in the oxygenator and if it eventually was removed through the membrane...

  • Oxygenator thrombosis: an international phenomenon. Schaadt, J. // Perfusion;1999, Vol. 14 Issue 6, p425 

    Oxygenator thrombosis, despite adequate anticoagulation, has become a recent concern amongst perfusionists worldwide. The phenomenon is characterized by a transient increase in oxygenator inlet pressure of up to 900 mmHg about 10-15 min after the institution of cardiopulmonary bypass (CPB)....