TITLE

Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators

AUTHOR(S)
de Somer, F.; Dierickx, P.; Dujardin, D.; Verdonck, P.; Nooten, G.V.
PUB. DATE
May 1998
SOURCE
Perfusion;1998, Vol. 13 Issue 3, p157
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
At present, air handling of a membrane oxygenator is generally studied by using an ultrasonic sound bubble counter. However, this is not a quantitative method and it does not give any information on where air was entrapped in the oxygenator and if it eventually was removed through the membrane for gas exchange. The study presented here gives a novel technique for the determination of the air-handling characteristics of a membrane oxygenator. The study aimed at defining not only the amount of air released by the oxygenator, but also the amount of air trapped within the oxygenator and/or removed through the gas exchange membrane. Two neonatal membrane oxygenators without the use of an arterial filter were investigated: the Polystan Microsafe and the Dideco Lilliput. Although the air trap function of both oxygenators when challenged with a bolus of air was similar, the Microsafe obtained this effect mainly by capturing the air in the heat exchanger compartment while the Lilliput did remove a large amount of air through the membrane. In conclusion, the difference in trap function was most striking during continuous infusion of air. Immediate contact with a microporous membrane, avoidance of high velocities within the oxygenator, pressure drop, transit time and construction of the fibre mat all contribute to the air-handling characteristics of a membrane oxygenator.
ACCESSION #
4089197

 

Related Articles

  • Editorial. Taylor, K. // Perfusion;1998, Vol. 13 Issue 3, p155 

    Editorial. Discusses on the ability of membrane oxygenators to handle and remove air. Quantification and localization of the air removal characteristics of membrane oxygenators; Analysis on the design and manufacture of cardiopulmonary bypass circuit components for neonatal and pediatric...

  • Microembolic signals and strategy to prevent gas embolism during extracorporeal membrane oxygenation. Zanatta, Paolo; Forti, Alessandro; Bosco, Enrico; Salvador, Loris; Borsato, Maurizio; Baldanzi, Fabrizio; Longo, Carolina; Sorbara, Carlo; longatti, Pierluigi; Valfrè, Carlo // Journal of Cardiothoracic Surgery;2010, Vol. 5, p1 

    Background: Extracorporeal membrane oxygenation (ECMO) supplies systemic blood perfusion and gas exchange in patients with cardiopulmonary failure. The current literature lacks of papers reporting the possible risks of microembolism among the complications of this treatment. In this study we...

  • Air trapping ability of the Spiral Goldâ„¢ membrane oxygenator: an ex vivo study. Mueller, Xavier M; Tevaearai, Hendrick T; van Ness, Karen; Horisberger, Judith; Augstburger, Monique; Burki, Marco; von Segesser, Ludwig K // Perfusion;1998, Vol. 13 Issue 1 

    Despite an overall improvement in cardiopulmonary bypass (CPB) technology and materials, air emboli still occur. The latest generation membrane oxygenator from Bentley Laboratories, the SpiralGoldâ„¢, was tested ex vivo for its air handling ability. The study was conducted on four calves....

  • High risk of intraoperative awareness during cardiopulmonary bypass with isoflurane administration via diffusion membrane oxygenators. Philipp, A; Wiesenack, C; Behr, R; Schmid, FX; Birnbaum, DE // Perfusion;May2002, Vol. 17 Issue 3, p175 

    In cardiac surgery with the aid of extracorporeal circulation (ECC), inhalation anaesthetics can be administered via the oxygenator. Until the recent advent of a new type of diffusion membrane oxygenator, we routinely added the inhalation agent, isoflurane, to the gas flow of a microporous...

  • CO2 embolism during minimally invasive vein harvesting Potapov, Evgenij V.; Buz, Semih; Hetzer, Roland // European Journal of Cardio-Thoracic Surgery;May2007, Vol. 31 Issue 5, p945 

    Abstract: CO2 embolism is a known, though rare, complication of procedures using CO2 insufflation. We report massive cardiac right atrial CO2 embolism during minimally invasive harvesting of a varicose great saphenous vein. The patient''s hemodynamics deteriorated significantly and needed to be...

  • The need for an organized ECMO-based respiratory program in Japan. Hashimoto, Satoru // Journal of Anesthesia;2012, Vol. 26 Issue 5, p647 

    The author suggests the importance of an organized extracorporeal membrane oxygenation (ECMO)-based respiratory program in Japan. He describes ECMO as an expanded clinical application of cardiopulmonary bypass introduced in the 1950s that allowed a longer period of support than other...

  • Testing neonateinfant membrane oxygenators with the University of Texas neonatal pulsatile cardiopulmonary bypass system in vitro. Ündar, A.; Holland, M.C.; Howelton, R.V.; Benson, C.K.; Ybarra, J.R.; Miller, O.L.; Rossbach, M.M.; Runge, M.M.; Johnson, S.B.; Sako, E.Y.; Calhoon, J.H. // Perfusion;1998, Vol. 13 Issue 5, p346 

    Neurologic complications are already well documented after cardiopulmonary bypass (CPB) procedures in neonates and infants. Physiologic pulsatile flow CPB systems may be the alternative to the currently used steady-flow CPB circuits. In addition to the pulsatile pump, a membrane oxygenator...

  • Effect of Carmeda® BioActive Surface coating versus Trilliumâ„¢ Biopassive Surface coating of the oxygenator on circulating platelet count drop during cardiopulmonary bypass. Palanzo, D.A.; Zarro, D.L.; Manley, N.J.; Montesano, R.M.; Quinn, M.; Elmore, B-A.; Gustafson, P.A.; Castagna, J.M. // Perfusion;Jul2001, Vol. 16 Issue 4, p279 

    An investigation was conducted to evaluate the effect that surface coating of the hollow-fiber membrane oxygenator had on circulating platelet count drop during cardiopulmonary bypass (CPB). Sixty patients undergoing non-emergency myocardial revascularization for coronary artery disease were...

  • Institutional experience with extracorporeal membrane oxygenation in lung transplantation Aigner, Clemens; Wisser, Wilfried; Taghavi, Shahrokh; Lang, György; Jaksch, Peter; Czyzewski, Damian; Klepetko, Walter // European Journal of Cardio-Thoracic Surgery;Mar2007, Vol. 31 Issue 3, p468 

    Abstract: Background: Extracorporeal membrane oxygenation (ECMO) is currently accepted in lung transplantation either to bridge patients to transplantation or to treat postoperatively arising severe primary graft failure. Based on promising initial experiences we have since 2001 implemented ECMO...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics