TITLE

Comment on “High efficiency electron spin polarization analyzer based on exchange scattering at Fe/W(001)” [Rev. Sci. Instrum. 79, 083303 (2008)]

AUTHOR(S)
Ocaña, Roberto
PUB. DATE
May 2009
SOURCE
Review of Scientific Instruments;May2009, Vol. 80 Issue 5, p057103
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A recent article [Winkelmann et al., Rev. Sci. Instrum. 79, 083303 (2008)] reports on a compact detector to analyze the electron spin based on exchange scattering at Fe(001) thin film grown on W(001) with chemisorbed oxygen in the p(1×1) structure. The results obtained with the same detector without oxygen coverage show, however, a better performance in terms of both asymmetry and figure of merit. It is also argued that the characterization performed only allows to make qualitative comparisons with other existing detectors based on the same exchange scattering since the polarization of the incident beam has not been measured in situ.
ACCESSION #
40638049

 

Related Articles

  • Control system for ALID-7 linear accelerator used in radiation processing Martin, D. I.; Martin, D.I.; Jianu, A.; Bestea, V.; Tome, M.; Toma, M.; Oproiu, C.; Marghitu, S. // Review of Scientific Instruments;Jul99, Vol. 70 Issue 7, p2984 

    Discusses the data acquisition and control system for the electron linear detector ALID-7 used for radiation processing. Construction and physical characteristics; Accelerator triggering system; Operational parameters control system; Conveyor control system; Potential applications.

  • A simple conversion electron detector for Mössbauer source experiments. Liao, L. X.; Ryan, D. H.; Altounian, Z. // Review of Scientific Instruments;Mar93, Vol. 64 Issue 3, p679 

    A vibration-free conversion electron detector has been constructed for Mössbauer source experiments with extremely low doping levels (∼1 ppm) of cobalt-57. While the overall efficiency is somewhat less than that of microfoil systems, the design is greatly simplified and it still yields...

  • Mean secondary electron yield of avalance electrons in the channels of a microchannel plate... Funsten, H.O.; Suszcynsky, D.M. // Review of Scientific Instruments;Oct96, Vol. 67 Issue 10, p3478 

    Studies the mean secondary electron yield of avalanche electrons in the channels of a microchannel plate (MCP) detector. Avalanche initiation by particle impact on a channel wall; Avalanche initiation by particle impact on the web; Secondary electron yield derived from studies using...

  • Method for determination of neutral atomic oxygen flux. Carruth, M. R.; DeHaye, R. F.; Norwood, J. K.; Whitaker, A. F. // Review of Scientific Instruments;Apr90, Vol. 61 Issue 4, p1211 

    A method for determining the flux of atomic oxygen atoms to a probe surface has been developed. Two probes are used. One is a glass probe enclosing a small, ceramic resistor heater and a thermocouple for determining the ambient local temperature. Another probe has a silver tip and inside it is...

  • Low-energy electron diffraction system using a position-sensitive detector. McRae, E. G.; Malic, R. A.; Kapilow, D. A. // Review of Scientific Instruments;Nov85, Vol. 56 Issue 11, p2077 

    A low-energy electron diffraction (LEED) system using a position-sensitive detector is described. The design requirements for LEED observations are outlined. Most of these requirements are realized in a system incorporating a miniature, movable electron gun and a position-sensitive detector of...

  • Upgrading the ATLAS Tile Calorimeter Electronics. Carrió, Fernando // EPJ Web of Conferences;2013, Issue 60, p1 

    This work summarizes the status of the on-detector and off-detector electronics developments for the Phase 2 Upgrade of the ATLAS Tile Calorimeter at the LHC scheduled around 2022. A demonstrator prototype for a slice of the calorimeter including most of the new electronics is planned to be...

  • New Products. Rubin, Lawrence G. // Physics Today;Jul2004, Vol. 57 Issue 7, p66 

    Presents several analytical instruments released as of July 2004. 13C Enhanced HCN Cold Probe from Varian Inc.; OSM-400 portable spectrometer from Newport Corp.; FoxyLite handheld oxygen sensor from Ocean Optics.

  • Low background-rate detector for 40-keV ions using a conversion dynode and a microchannel-plate electron multiplier to reject low-energy ions, electrons, and photons. Friedman, Peter G.; Bertsche, Kirk J.; Michel, Maynard C.; Morris, Donald E.; Muller, Richard A.; Tans, Pieter P. // Review of Scientific Instruments;Jan1988, Vol. 59 Issue 1, p98 

    We have developed and tested an inexpensive ion detector with dark-count rates below 10-4 s-1 and excellent background rejection. Each 40-keV ion that strikes a grazing-incidence Al2O3 conversion dynode ejects a few tens of secondary electrons, which enter separate pores of a microchannel plate...

  • A CdS photoconductivity gas sensor as an analytical tool for detection and analysis of hazardous gases in the environment. Miremadi, Bijan K.; Colbow, Konrad; Harima, Yutaka // Review of Scientific Instruments;Oct97, Vol. 68 Issue 10, p3898 

    Develops a highly sensitive gas sensor for detection and analytical identification of hazardous gases, by depositing partially crystalline powder from an aqueous suspension of CdS powder on an alumina substrate. Sample preparation; Schematic diagram of the apparatus and measuring system;...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics