TITLE

Separation of beta-human chorionic gonadotropin and immunoglobulin G by a miniaturized size exclusion chromatography column

AUTHOR(S)
Yang, Yongmo; Chae, Junseok
PUB. DATE
April 2009
SOURCE
Applied Physics Letters;4/27/2009, Vol. 94 Issue 17, p173902
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
This report describes a miniaturized size exclusion chromatography column that effectively preseparates raw samples for medical point-of-care testing (POCT) devices. The minicolumn is constructed of polydimethylsiloxane fabricated on a glass slide. The minicolumn separates 300 ng/ml of beta-human chorionic gonadotropin (β-hCG) from an immunoglobulin G (IgG)-rich solution (100 μg/ml) in 7.7 min, with 2.23 resolution and 0.018 mm plate height. The complete analyte discrimination shows potential for the sample preparation stage of POCT devices for cancer screening, prognosis, and monitoring.
ACCESSION #
38712277

 

Related Articles

  • Human chorionic gonadotropin (hCG) testing -- Part II. Diwan, Charbel Abou // MLO: Medical Laboratory Observer;Mar2011, Vol. 43 Issue 3, p26 

    The article offers information on human chorionic gonadotropin (hCG) testing. It states that there are two types of hCG tests, one which is for detecting intact dimer and another which is for detecting intact dimer and free β-subunit. It mentions that these assays are limited due to the...

  • Bedside point of care toxicology screens in the ED: Utility and pitfalls. Bhalla, Ashish // International Journal of Critical Illness & Injury Science;Jul-Sep2014, Vol. 4 Issue 3, p257 

    Exposure to drugs and toxins is a major cause for patients' visits to the emergency department (ED). For most drugs-of-abuse intoxication, ED physicians are skeptical to rely on results of urine drug testing for emergent management decisions. This is partially because immunoassays, although...

  • Comparison of the Simplify D-dimer assay performed at the bedside with a laboratory-based quantitative D-dimer assay for the diagnosis of pulmonary embolism in a low prevalence emergency department population. Runyon, M. S.; Beam, D. M.; King, M. C.; Lipford, E. H.; Kline, J. A. // Emergency Medicine Journal;Feb2008, Vol. 25 Issue 2, p70 

    Background: The immunofiltration D-dimer assay could allow point-of-care testing for pulmonary embolism (PE). A study was undertaken to compare a clinician-performed qualitative D-dimer assay with the automated quantitative D-dimer test. Methods: A prospective observational study was conducted...

  • Simultaneous Quantitative Detection of Helicobacter Pylori Based on a Rapid and Sensitive Testing Platform using Quantum Dots-Labeled Immunochromatiographic Test Strips. Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang // Nanoscale Research Letters;2/3/2016, Vol. 11 Issue 1, p1 

    Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers...

  • Simplified purification of equine chorionic gonadotropin (eCG)--an example of the use of magnetic microsorbents for the isolation of glycoproteins from serum. Müller, Christine; Wagner, Kerstin; Frankenfeld, Katrin; Franzreb, Matthias // Biotechnology Letters;May2011, Vol. 33 Issue 5, p929 

    Classical purification of the glycoprotein equine chorionic gonadotropin (eCG) from serum includes pH fractionation with metaphosphoric acid, two ethanol precipitation steps as well as dialysis followed by fixed-bed chromatography. A simplified process requiring only 1/3 of the solvent and...

  • POCT.  // MLO: Medical Laboratory Observer;Aug2015, Vol. 47 Issue 8, p5 

    The article presents questions to be asked in evaluating the efficacy of ambulatory testing in relation to point-of-care testing (POCT), recommended by Becky Clarke, executive vice president for POC at POC and laboratory billing software solutions provider TELCOR Corporation.

  • Point-of-care testing: a look ahead. Lewis, Martyn // MLO: Medical Laboratory Observer;Aug2015, Vol. 47 Issue 8, p27 

    The article discusses the future of point-of-care technology (POCT) and developments that will help bring its objectives to reality. Topics discussed include joined-up approach to patient management needed to enable feeding of POCT data into laboratory information systems (LIS), expected update...

  • Correction.  // H&HN: Hospitals & Health Networks;Nov2006, Vol. 80 Issue 11, p10 

    A correction to the article on point-of-care testing that was published in the September 2006 issue is presented.

  • The Getting the Purification and the Characterization of Species' Immunoglobulin G (IgG) and Anti-immunoglobulin G Serum for Dog, Goat and Rabbit. Turcu, D.; Oporanu, Mariana; Grigorescu, P.; Condur, D.; Petruţ, T.; Simion, Vioteta; Călin, V. // Bulletin of the University of Agricultural Sciences & Veterinary;2010, Vol. 67 Issue 1, p346 

    The research aimed at preparing, purifying and characterizing the immunoglobulin 0, for dog, goat and rabbit, and the anti-IgG serum for the same species. The IgG species purification was done through precipitation, using ammonium sulfate solution and ion exchange chromatography...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics