TITLE

Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

AUTHOR(S)
Hashimoto, Masatoshi; Tomita, Tetsuya; Sawada, Koichi; Fujibuchi, Toshioh; Nishio, Teiji; Nakagawa, Keiichi
PUB. DATE
April 2009
SOURCE
Review of Scientific Instruments;Apr2009, Vol. 80 Issue 4, p045101
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10×10 cm2 field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.
ACCESSION #
38611928

 

Related Articles

  • The Effect of Lead Intensification Screens on Film: Modeling and Experiment. Wendt, S.; Gray, J.; Zhou, C. // AIP Conference Proceedings;2004, Vol. 700 Issue 1, p530 

    A physics-based, intensification screen model, using lead as an example, has been developed. Comparisons to experimental results are shown. The dominant effect in producing the intensification is from photoelectrons ejected from a 24 – 40 micron layer of lead near the film with Compton...

  • Dosimetric evaluation of a new collimator insert system for stereotactic radiotherapy. T Paschalis; P Sandilos; E Tatsis; P Karaiskos; C Antypas; C Chatzigiannis; K Dardoufas; E Georgiou; L Vlachos // British Journal of Radiology;Jun2007, Vol. 80 Issue 954, p446 

    The prototype of a stereotactic collimator set developed in our department is evaluated for clinical use. This set consists of three cylindrical blocks mounted on a tray which slides in the wedge insert of a Siemens Primus accelerator. Each block has a collimating hole along its long axis to...

  • Particle simulation on x-ray emissions from ultra-intense laser produced plasmas. Sentoku, Y.; Mima, K. // Physics of Plasmas;Dec98, Vol. 5 Issue 12, p4366 

    Investigates the production of plasmas from ultra-short intense laser on x-ray emissions by particle simulations. Integration of the collisional absorption and x-ray bremsstrahlung processes in particle simulation; Utilization of Monte Carlo method in the bremsstrahlung processes integration;...

  • Development of a distributed read-out imaging TES X-ray microcalorimeter. Trowell, S.; Holland, A. D.; Fraser, G. W.; Goldie, D.; Gu, E. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p267 

    We report on the development of a linear absorber detector for one-dimensional imaging spectroscopy, read-out by two Transition Edge Sensors (TESs). The TESs, based on a single layer of iridium, demonstrate stable and controllable superconducting-to-normal transitions in the region of 130 mK....

  • Theoretical studies of the electron scattering effect on developed pattern profiles in x-ray lithography. Murata, Kenji // Journal of Applied Physics;1/15/1985, Vol. 57 Issue 2, p575 

    Presents theoretical studies of the electron scattering effect on developed pattern profiles in X-ray lithography. Description of a Monte Carlo simulation of the production of photoelectrons and Auger electrons in a thin positive resist polymethyl methacrylate; Production of photoelectrons and...

  • Monte Carlo simulation of x-ray spectra generated by kilo-electron-volt electrons. Llovet, X.; Sorbier, L.; Campos, C. S.; Acosta, E.; Salvat, F. // Journal of Applied Physics;4/1/2003, Vol. 93 Issue 7, p3844 

    We present a general algorithm for the simulation of x-ray spectra emitted from targets of arbitrary composition bombarded with kilovolt electron beams. Electron and photon transport is simulated by means of the general-purpose Monte Carlo code PENELOPE, using the standard, detailed simulation...

  • Monte Carlo simulation of x-ray spectra in electron probe microanalysis: Comparison of continuum with experiment. Ding, Z.-J.; Shimizu, R.; Obori, K. // Journal of Applied Physics;12/1/1994, Vol. 76 Issue 11, p7180 

    Presents a Monte Carlo simulation code developed to describe the x-ray generation in a specimen for electron probe microanalysis (EPMA), enabling x-ray spectra observed by EPMA to be reproduced theoretically. Background on EPMA; Procedures for the Monte Carlo simulation; Experiment methods used...

  • The energy dispersive x-ray detector: A quantitative model. Joy, David C. // Review of Scientific Instruments;Sep85, Vol. 56 Issue 9, p1772 

    When a Si(Li) solid-state energy dispersive detector is used to collect x-ray photons with energies below 2 keV the characteristic peaks in the spectrum show significant deviations from the ideal Gaussian shape observed for higher energy photons. This effect is due to incomplete collection of...

  • Personal monitor glass badge: theoretical dosemeter response calculated with the Monte Carlo transport code MCNPX. Hocine, Nora; Donadille, Laurent; Huet, Christelle; Itié, Christian; Clairand, Isabelle // Radiation Protection Dosimetry;Mar2011, Vol. 144 Issue 1-4, p231 

    This paper describes the results of the simulation of a radiophotoluminescent (RPL) dosemeter with the Monte Carlo transport code MCNPX. The aim of this study is to calculate the response with MCNPX of the RPL dosemeter in terms of equivalent doses Hp (0.07) and Hp(10) using X-ray photon...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics