TITLE

A new magnetic bearing using Halbach magnet arrays for a magnetic levitation stage

AUTHOR(S)
Choi, Young-Man; Lee, Moon G.; Gweon, Dae-Gab; Jeong, Jaehwa
PUB. DATE
April 2009
SOURCE
Review of Scientific Instruments;Apr2009, Vol. 80 Issue 4, p045106
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Next-generation lithography requires a high precision stage, which is compatible with a high vacuum condition. A magnetic levitation stage with six degrees-of-freedom is considered state-of-the-art technology for a high vacuum condition. The noncontact characteristic of magnetic levitation enables high precision positioning as well as no particle generation. To position the stage against gravity, z-directional electromagnetic levitation mechanisms are widely used. However, if electromagnetic actuators for levitation are used, heat is inevitably generated, which deforms the structures and degrades accuracy of the stage. Thus, a gravity compensator is required. In this paper, we propose a new magnetic bearing using Halbach magnet arrays for a magnetic levitation stage. The novel Halbach magnetic bearing exerts a force four times larger than a conventional magnetic bearing with the same volume. We also discuss the complementary characteristics of the two magnetic bearings. By modifying the height of the center magnet in a Halbach magnetic bearing, a performance compromise between levitating force density and force uniformity is obtained. The Halbach linear active magnetic bearing can be a good solution for magnetic levitation stages because of its large and uniform levitation force.
ACCESSION #
38611901

 

Related Articles

  • High-precision magnetic levitation device with electro-optical feedback. Echevarria, Isabel; Rubio, Miguel A. // Review of Scientific Instruments;Jul1995, Vol. 66 Issue 7, p3931 

    Reports on a magnetic levitation device with electro-optical feedback which allows for precise stabilization of the vertical position of the levitated piece (LP). Monitoring of the vertical position of the LP through the reflection of a laser beam on a mirror placed in the upper part of the LP;...

  • A magnetic diagnostic on Tore Supra. Moreau, Ph.; Defrasne, P.; Joffrin, E.; Saint Laurent, F.; Martin, G. // Review of Scientific Instruments;Oct2003, Vol. 74 Issue 10, p4324 

    A magnetic diagnostic has been installed in Tore Supra during the year 2000. It has been designed to be compatible with the configuration Composants Internes Et Limiteur (CIEL) requirements. It consists of a set of 424 dedicated magnetic sensors, pickup coils, and flux loops. The entire system...

  • The project of using a compact SR source at the Siberian microelectronic center. Sinyukov, M. P.; Makarov, O. A. // Review of Scientific Instruments;Jan1992, Vol. 63 Issue 1, p774 

    The project for the x-ray lithography facility using a compact storage ring SIBERIA-AS is considered. The SR source with 600-MeV electron energy and an orbit circumference of about 3 m has an ironless superconducting azimuthally symmetrical magnet. It allows us to install up to 15 SR beam lines....

  • Quality Control of Cores Made of Nanocrystalline Alloys Intended for Primary Transducers of a Drill-Hole Magnetometer—Inclinometer. Astrakhantsev, Yu. G.; Korzunin, G. S.; Lavrent'ev, A. G.; Potapov, A. P.; Sherendo, T. A.; Shulika, V. V. // Russian Journal of Nondestructive Testing;Apr2004, Vol. 40 Issue 4, p264 

    The influence of different types of thermal magnetic treatment of ferroprobe cores made of the Fe73.5Cu1Nb3Si13.5B9 nanocrystalline alloy on the characteristics of primary transducers of a drill-hole magnetometer has been studied. The informative parameters of the Barkhausen effect (a stepwise...

  • A compact nanopositioning stage with high vibrational eigenfrequencies. Ball, S. J.; Folsom, C.; McLean, A. B. // Review of Scientific Instruments;Nov2005, Vol. 76 Issue 11, p113702 

    A compact nanopositioning stage is described that has high vibrational eigenfrequencies and is, therefore, insensitive to external vibrations. The high eigenfrequencies are produced by a rigid structure that is designed so that it does not degrade the motional performance of the stage....

  • Photoemission microscope safely measures features 20nm small.  // Electronics Weekly;9/13/2006, Issue 2258, p1 

    This article reports that a new photoemission microscope has been developed by a European consortium, which can measure features as small as 20nm without destroying the sample. The members of the consortium are Universities of Bielefeld and Mainz, Germany, and German instrument maker Focus....

  • Adsorption equilibria of CO/H2 with a magnetic suspension balance. Dreisbach, F.; Seif, R.; L�sch, H. W. // Journal of Thermal Analysis & Calorimetry;2003, Vol. 71 Issue 1, p73 

    Adsorption equilibria of pure gases and binary gas mixtures can be measured with a new magnetic suspension balance. For this measurement no additional concentration measurement is required, neither for the gas phase nor for the adsorbed phase. The new instrument allows gravimetric adsorption...

  • Optics for five-dimensional measurement for correction of vertical displacement error due to attitude of floating body in superconducting magnetic levitation system. Shiota, Fuyuhiko; Morokuma, Tadashi // Review of Scientific Instruments;Sep2006, Vol. 77 Issue 9, p096103 

    An improved optical system for five-dimensional measurement has been developed for the correction of vertical displacement error due to the attitude change of a superconducting floating body that shows five degrees of freedom besides a vertical displacement of 10 mm. The available solid angle...

  • The near-field acoustic levitation of high-mass rotors. Hong, Z. Y.; Lü, P.; Geng, D. L.; Zhai, W.; Yan, N.; Wei, B. // Review of Scientific Instruments;2014, Vol. 85 Issue 10, p1 

    Here we demonstrate that spherical rotors with 40 mm diameter and 0-1 kg mass can be suspended more than tens of micrometers away from an ultrasonically vibrating concave surface by near-field acoustic radiation force. Their rotating speeds exceed 3000 rpm. An acoustic model has been developed...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics