TITLE

Electrical and magnetic interaction along a defective single-walled carbon nanotube channel

AUTHOR(S)
Lee, Yun-Hi; Noh, Ji-Young
PUB. DATE
April 2009
SOURCE
Applied Physics Letters;4/20/2009, Vol. 94 Issue 16, p163109
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
We study the electrical and magnetic interaction in a low conduction regime for laterally as-grown defective single-walled carbon nanotube channel as functions of bias and gate voltage, combined with direct current and magnetic phase image by current-atomic force microscopy and magnetic force microscopy. For the SWNT field effect transistor at very low bias direct imaging of the current flow on the 0.9 and 2 nm diameter single-walled nanotube (SWNT) devices revealed that locally conducting islands occur along the SWNT channel, and become an origin of electrical behavior in the stage of minimal conduction. In contrast, the homogenous magnetic interaction along the as-laterally-grown individual SWNT channel observed by magnetic force measurements suggest a hint that as-grown single SWNT channel may be a reliable candidate for use in magnetoelectronics, regardless of whether clean or defective SWNT.
ACCESSION #
38225284

 

Related Articles

  • High resolution switching magnetization magnetic force microscopy. Cambel, V.; Precner, M.; Fedor, J.; Sˇoltýs, J.; Tóbik, J.; Sˇcˇepka, T.; Karapetrov, G. // Applied Physics Letters;2/11/2013, Vol. 102 Issue 6, p062405 

    We introduce switching magnetization magnetic force microscopy based on two-pass scanning atomic force microscopy with reversed tip magnetization between the scans. Within this approach the sum of the scanned data with reversed tip magnetization depicts local van der Waals forces, while their...

  • Magnetic force microscopy measurements in external magnetic fields—comparison between coated probes and an iron filled carbon nanotube probe. Wolny, F.; Mühl, T.; Weissker, U.; Leonhardt, A.; Wolff, U.; Givord, D.; Büchner, B. // Journal of Applied Physics;Jul2010, Vol. 108 Issue 1, p013908 

    We performed magnetic force microscopy (MFM) measurements in external magnetic fields parallel to the sample plane to qualitatively study their effect on the magnetization of different kinds of MFM probes. As a test structure we used an array of rectangular ferromagnetic thin film elements...

  • Stray fields of iron electrodes for spin-polarized transport. Barthelmess, M.; Thieme, A.; Eiselt, R.; Meier, G. // Journal of Applied Physics;5/15/2003, Vol. 93 Issue 10, p8400 

    In semiconductor spintronic devices that incorporate ferromagnetic materials the stray-field configuration in the plane of the two-dimensional electron system is of crucial importance. We investigate the stray fields of iron electrodes suitable as injector and detector for spin-polarized...

  • Correlating spin transport and electrode magnetization in a graphene spin valve: Simultaneous magnetic microscopy and non-local measurements. Berger, Andrew J.; Page, Michael R.; Hua Wen; McCreary, Kathleen M.; Bhallamudi, Vidya P.; Kawakami, Roland K.; Hammel, P. Chris // Applied Physics Letters;2015, Vol. 107 Issue 14, p1 

    Using simultaneous magnetic force microscopy and transport measurements of a graphene spin valve, we correlate the non-local spin signal with the magnetization of the device electrodes. The imaged magnetization states corroborate the influence of each electrode within a one-dimensional spin...

  • Material dependence of magnetic force microscopy performance using carbon nanotube probes: Experiments and simulation. Kuramochi, H.; Asada, H.; Uzumaki, T.; Yui, H.; Iitake, M.; Takano, F.; Akinaga, H.; Manago, T. // Journal of Applied Physics;2014, Vol. 115 Issue 9, p093907-1 

    We investigated the dependence of the performance of magnetic force microscopy (MFM) on magnetic coating materials by using carbon nanotube (CNT) probes. The magnetic structures of CNT-MFM probes with CoFe(80:20), CoFe(30:70), and CoCr(80:20) coatings were essentially the same in the...

  • Magnetic force microscopy sensors providing in-plane and perpendicular sensitivity. Mühl, T.; Körner, J.; Philippi, S.; Reiche, C. F.; Leonhardt, A.; Büchner, B. // Applied Physics Letters;9/10/2012, Vol. 101 Issue 11, p112401 

    We present a bimodal magnetic force microscopy sensor consisting of a conventional cantilever beam, a spacer element, and an iron-filled carbon nanotube. Depending on the mode of the cantilever's resonant flexural vibration, the sensor is sensitive to magnetic field derivatives parallel and...

  • Conductance of individual channels in a carbon nanotube field-effect transistor studied by magnetic force microscopy. Ato, Masayuki; Takahashi, Takuji; Okigawa, Yuki; Mizutani, Takashi // Journal of Applied Physics;Dec2009, Vol. 106 Issue 11, p114315-1 

    We observed current-induced magnetic fields using magnetic force microscopy (MFM) to investigate the channel properties of carbon nanotube field-effect transistors (CNT-FETs). We first modified the shape of a MFM cantilever to enhance its response to magnetic force and then observed the MFM...

  • Iron-filled carbon nanotubes as probes for magnetic force microscopy. Wolny, Franziska; Weissker, Uhland; Mühl, Thomas; Leonhardt, Albrecht; Menzel, Siegfried; Winkler, Andreas; Büchner, Bernd // Journal of Applied Physics;Sep2008, Vol. 104 Issue 6, p064908 

    Iron-filled carbon nanotubes (Fe-CNTs) were used to prepare probes for magnetic force microscopy (MFM) by attaching them to the tips of conventional atomic force microscopy cantilevers. An optimized chemical vapor deposition process, employing a two stage furnace and ferrocene as a precursor,...

  • Monopolelike probes for quantitative magnetic force microscopy: Calibration and application. Vock, S.; Wolny, F.; Mühl, T.; Kaltofen, R.; Schultz, L.; Büchner, B.; Hassel, C.; Lindner, J.; Neu, V. // Applied Physics Letters;12/20/2010, Vol. 97 Issue 25, p252505 

    A local magnetization measurement was performed by magnetic force microscopy (MFM) to determine magnetization in domains of an exchange coupled [Co/Pt]/Co/Ru multilayer with predominant perpendicular anisotropy. The quantitative MFM measurements were conducted with an iron-filled carbon nanotube...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics