The large Atriums of airports and railway stations facilitate the access to transport vehicles including shopping malls, cultural spaces, etc. For this reason, they are used by an elevated number of passengers and visitors. Numerous malls contain a large atrium too, as a principal access or as a food court, and they usually have high occupant loads. In case of fire, the smoke can affect human health seriously, and people may be unable to reach a safe place before being overcome by the conditions created by the fire. The traditional approach to fire protection by compartmentation is not applicable to these large volume spaces and the ability of sprinklers to suppress fire in spaces with high ceilings is limited. This work evaluated—using scale tests, fire computer modeling and analytical methods—a comparative analysis of the different results obtained for the smoke control in large atria when the smoke filling approach is applied. Smoke layer and plume temperatures have been registered during the scale test—based on the Froude Modeling—and they have been compared opposite to the FDS scale simulation and the FDS large scale simulation. Smoke layer descend has been studied and compared for the scale test, the computer simulations developed and the empirical equations used. The results demonstrated that the evacuation time calculation is conservative when the zone computer model CFAST, the field computer model FDS or the empirical equations are used, although it turns out to be difficult to define the interface height based on the temperatures registered during the scale tests. The zone computer models generate results faster than field computer models or smoke tests, so it would be necessary to develop better calculation algorithms to define the smoke layer interface.


Related Articles

  • Keeping Your Head Out of Water. Romeo, Jim // Reeves Journal: Plumbing, Heating, Cooling;Mar2003, Vol. 83 Issue 3, p52 

    Provides an overview of the structure of codes and standards that govern fire sprinkler installation in buildings. Names of professional societies providing the standard of how those codes will be met; Use of Uniform Building Codes by builders; Reasons behind the imposition of codes and...

  • EXTINGUISHING SYSTEMS.  // Fire Safety Engineering;Dec2008/Jan2009, Vol. 15 Issue 10, p35 

    The article focuses on automatic extinguishing and suppression systems. In 2008, the Fire Industry Association of Great Britain published Europe's first code and practice in designing and installing fire extinguishing systems. The article features a sprinkler system that sprays a fine...

  • Designing FOR LIFE SAFETY: Beyond Sprinklers, Fans, And Dampers. Staton, Tom; Heckler, Kieth A. // Engineered Systems;Nov2007, Vol. 24 Issue 11, p48 

    The article discusses the authors' views regarding factors that should be considered by life-safety system designers in the U.S. The authors analyzed smoke control systems for fire and life safety in an occupied structure. They said that these systems should be secured with automatic wet-pipe...

  • NO MATCH FOR FAHRENHEIT 2000.  // Concrete Products;Aug2004, Vol. 107 Issue 8, p4 

    Editorial. Comments on the need for concrete wall and building system stakeholders to harmonize compartmentation, a performance characteristic common to cast-in-place, precast and masonry design. Advantages over simply relying on automatic fire sprinklers; Concrete industry engineering and...

  • TRAGEDIES FUEL SPRINKLER PERFORMANCE MYTHS. Marsh, Don // Concrete Products;Mar2003, Vol. 106 Issue 3, p4 

    Editorial. Comments on several myths about the use of automatic fuel sprinkler. Role of sprinklers in building-occupant safety; Three complementary systems to reduce the risk of death and loss of property due to fire.

  • On the use of scenario analysis in combination with prescriptive fire safety design requirements. Bjelland, Henrik; Borg, Audun // Environment Systems & Decisions;Mar2013, Vol. 33 Issue 1, p33 

    Experience with fire safety engineering under a performance-based fire safety regulation regime shows that the majority of the analyses performed are scenario based. A comparison with purely pre-accepted performance requirement is made in order to assess the relative safety level of the...

  • The Safety of Automatic Fire Sprinklers.  // Buildings;Jul2008, Vol. 102 Issue 7, p52 

    The article presents questions and answers related to safety of automatic fire sprinklers including the effectiveness of fire sprinklers, studies on the effectiveness of fire sprinklers, and risk of fire sprinklers to accidental discharge.

  • Why CISD Should Install A Full Sprinkler System At Canyon Lake Middle School.  // Bulverde Standard (Canyon Lake, TX);8/22/2007, Vol. 23 Issue 34, p12 

    The article presents stories from various U.S. states on the benefits and services provided by maintaining a full fire sprinkler system.

  • FIRE PRODUCTS.  // Canadian Consulting Engineer;May2003, Vol. 44 Issue 3, p38 

    Features several products for fire protection and prevention. Detection and alarms; Actuators; Fire stops; Sprinklers; Tunnels.


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics