TITLE

Digital Subtraction Radiography for the Assessment of Changes in Peri-Implant Bone Density

AUTHOR(S)
Brägger, Urs; Bürgin, Walter; Lang, Niklaus P.; Buser, Daniel
PUB. DATE
June 1991
SOURCE
International Journal of Oral & Maxillofacial Implants;Summer1991, Vol. 6 Issue 2, p1
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Digital subtraction radiography is proposed as a potential diagnostic tool for implant research and patient monitoring. Examples of the application of this technique are given observing peri-implant density changes during the early healing phase and during ligature-induced peri-implantitis in an animal model. Additional cases document the loss of peri-implant bone density associated with an infection and increase in density caused by remodeling after functional loading of an implant with a single crown. Digital subtraction radiography might be one of the most sensitive noninvasive methods for assessing subtle density changes in peri-implant tissues, providing additional diagnostic information on im plant tissue integration and maintenance.
ACCESSION #
38012683

 

Related Articles

  • Numerical simulation of fluid field and in vitro three-dimensional fabrication of tissue-engineered bones in a rotating bioreactor and in vivo implantation for repairing segmental bone defects. Song, Kedong; Wang, Hai; Zhang, Bowen; Lim, Mayasari; Liu, YingChao; Liu, Tianqing // Cell Stress & Chaperones;Mar2013, Vol. 18 Issue 2, p193 

    In this paper, two-dimensional flow field simulation was conducted to determine shear stresses and velocity profiles for bone tissue engineering in a rotating wall vessel bioreactor (RWVB). In addition, in vitro three-dimensional fabrication of tissue-engineered bones was carried out in...

  • Subtraction Radiography in Oral Implantology. Nicopoulou-Karayianni, Kety; Brägger, Urs; Lang, N. P. // International Journal of Periodontics & Restorative Dentistry;Jun1997, Vol. 17 Issue 3, p220 

    Radiographic examinations in connection with implant installation are important means to diagnose changes in the bone tissue following implantation. During the healing and early remodeling phases, a slight reduction of the marginal bone height occurs in the first year after implantation, which...

  • HOW USEFUL IS THE CT SCAN IN THE ANALYSIS OF THE MANDIBULAR BONE. Teslaru, Silvia; Indrei, Anca; Mârţu, Silvia; Duvernoil, Nadine Martin; Haba, Danisia // Romanian Journal of Functional & Clinical, Macro- & Microscopica;Oct2010, Vol. 9 Issue 4, p408 

    This study aims to assess how useful are the dental CT scans in the investigation of severe periodontal disease for diagnosis purposes and whether the jawbone density is correlated or not with the number of teeth lost and with the superior and inferior mandibular panoramic index. Materials and...

  • The Scandinavian Total Ankle Replacement. Brunner, Samuel; Barg, Alexej; Knupp, Markus; Zwicky, Lukas; Kapron, Ashley L.; Valderrabano, Victor; Hintermann, Beat // Journal of Bone & Joint Surgery, American Volume;4/17/2013, Vol. 95-A Issue 8, p711 

    Background: The objective of this study was to determine the long-term survivorship and clinical and radiographic results of the Scandinavian Total Ankle Replacement (STAR). Methods: From February 1996 to March 2000, seventy-seven ankles in seventy-two patients (thirty-seven female and...

  • Radiation absorbed doses at compact bone-titanium interfaces in diagnostic radiography: a Monte Carlo approach. Nicopoulou-Karayianni, K.; Koligliatis, T.; Donta-Bakogianni, C.; Karayiannis, A.; Litsas, J. // Dentomaxillofacial Radiology;Sep2003, Vol. 32 Issue 5, p327 

    Estimation of the radiation absorbed dose at cortical tissue-implant interfaces in diagnostic radiology. Usage of the Monte Carlo simulation for cortical bone-implant interface; Effect of the implant on the radiation dose to the cortical bone surrounding the implant; Consideration on the...

  • Evaluation of Zotarolimus-Eluting Metal Stent in Animal Ureters. Kallidonis, Panagiotis; Kitrou, Panagiotis; Karnabatidis, Dimitrios; Kyriazis, Iason; Kalogeropoulou, Christina; Tsamandas, Athanasios; Apostolopoulos, Dimitrios J.; Vrettos, Theofanis; Liourdi, Despoina; Spiliopoulos, Stavros; Al-Aown, Abdulrahman; Scopa, Chrisoula D.; Liatsikos, Evangelos // Journal of Endourology;Oct2011, Vol. 25 Issue 10, p1661 

    AbstractBackground and Purpose:Drug-eluting stents proved to minimize neointimal hyperplasia in coronary vessels. Hyperplastic reaction is the most common unwelcome event related to the use of metal mesh stents in the ureter. We evaluated the effect of zotarolimus-eluting stent (ZES) Endeavor...

  • The Value of SPECT/CT in Monitoring Prefabricated Tissue-Engineered Bone and Orthotopic rhBMP-2 Implants for Mandibular Reconstruction. Zhou, Miao; Peng, Xin; Mao, Chi; Tian, Jia-he; Zhang, Shu-wen; Xu, Fang; Tu, Jing-jing; Liu, Sheng; Hu, Min; Yu, Guang-yan // PLoS ONE;9/4/2015, Vol. 10 Issue 9, p1 

    Bone tissue engineering shows good prospects for mandibular reconstruction. In recent studies, prefabricated tissue-engineered bone (PTEB) by recombinant human bone morphogenetic proteins (rhBMPs) applied in vivo has found to be an effective alternative for autologous bone grafts. However, the...

  • Loss of Tibial Bone Density in Patients with Rotating- or Fixed-platform TKA. Munro, Jacob T.; Pandit, Salil; Walker, Cameron G.; Clatworthy, Mark; Pitto, Rocco P. // Clinical Orthopaedics & Related Research;Mar2010, Vol. 468 Issue 3, p775 

    Little is known about tibial bone remodeling with TKA and its clinical relevance. We performed a randomized clinical trial to compare tibial bone density changes in cemented components with different bearing designs. Bone density changes were assessed using quantitative computed tomography...

  • An in vitro study of factors affecting the primary stability of orthodontic mini-implants. Holm, Lindsy; Cunningham, Susan J.; Petrie, Aviva; Cousley, Richard R.J. // Angle Orthodontist;Nov2012, Vol. 82 Issue 6, p1022 

    Objectives: To evaluate the effects of mini-implant features (length, design, core diameter), insertion technique (insertion angle, cortical punch), and cortical bone depth and density on miniimplant primary stability. The effect of mini-implant reinsertion was also investigated. Materials and...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics