TITLE

Assessment of a Recently Introduced Fluoroelastomeric Soft Lining Material

AUTHOR(S)
Collis, John
PUB. DATE
September 1993
SOURCE
International Journal of Prosthodontics;Sep/Oct1993, Vol. 6 Issue 5, p440
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The clinical usefulness of soft denture-lining materials is well established. This laboratory-based comparative study of a heat-processed silicone (Molloplast-B) and a recently introduced fluoroelastomeric soft lining material (Novus) evaluated absorption behaviour in distilled water; the softness of the materials at different thicknesses, both dry and after immersion in water; and their compatibility with denture cleansers. A significant absorption of water, greater than 5% by weight, was displayed by Novus after 4 months' immersion. The softness of different thicknesses of Novus (up to 1.35 mm) increased significantly upon immersion over the same period when compared to Molloplast-B, which showed no change. Some surface degradation of Novus was evident upon exposure to denture cleansers that was not apparent with Molloplast-B.
ACCESSION #
37703227

 

Related Articles

  • Torque Required to Loosen Single-Tooth Implant Abutment Screws Before and After Simulated Function. Breeding, Larry C.; Dixon, Donna L.; Nelson, Eric W.; Tietge, James D. // International Journal of Prosthodontics;Sep/Oct1993, Vol. 6 Issue 5, p435 

    The amount of torque required to loosen screws from three different antirotational screw-retained abutment/implant combinations was compared (with and without adhesive sealant applied) after 6 kg of force was applied during simulated intraoral movements. Movements were generated over two...

  • "Microbiological and clinical outcomes and patient satisfaction for two treatment options in the edentulous lower jaw after 10 years of function" Ley, John // Journal of Oral Implantology;2005, Vol. 31 Issue 6, p314 

    The article discusses research being done on implant prosthetics. It references a study by M. Quirynen et al published in the 2005 issue of "Clinical Oral Implants Research." It presents the findings of the research.

  • A Retrospective Study on the Maintenance and Repair of Implant-Supported Prostheses. Walton, Joanne N.; MacEntee, Michael I. // International Journal of Prosthodontics;Sep/Oct1993, Vol. 6 Issue 5, p451 

    This study reviewed the prosthodontic treatment and aftercare required by 29 patients with 32 implant-supported prostheses (12 fixed and 20 removable) placed on 107 implants. Patients were followed for 4 to 39 months. The majority of implant-supported prostheses (53%) were placed in the...

  • Implant Treatment in Elderly Patients. Jemt, Torsten // International Journal of Prosthodontics;Sep/Oct1993, Vol. 6 Issue 5, p456 

    A group of 48 patients, all more than 80 years old (mean age 82.7 years) at first implant surgery, who received a total of 254 implants, were followed in one clinical center. Of the exposed implants, 6 of 238 (2.5%) were found to be loose at second-stage surgery, and another 3 implants were lost...

  • Inaccurate Fit of Implant Superstructures. Part II: Efficacy of the Preci-disc System for the Correction of Errors. Uludamar, Altay; Leung, Theresa // International Journal of Prosthodontics;Jan/Feb1996, Vol. 9 Issue 1, p16 

    The Preci-disc prosthetic system for dental implants is designed to compensate for casting inaccuracies and to reduce stresses generated on the superstructure and implant components. This laboratory study compared stresses induced on the implant superstructure with various sizes of vertical...

  • Principles and treatment planning considerations for successful endosteal blade implantology (II). Judy, Kenneth W. M.; Weis, Charles M. // Quintessence International;Jan1979, Vol. 10 Issue 1, p9 

    The article discusses the principles and treatment planning considerations of successful endosteal blade implantology. Several types of blades can be used in the implants including distal abutment blades, intra-abutment blades and single tooth blades. As cited, intensive preoperative measures...

  • Development and Manufacture of Prosthodontic Components: Do We Need Changes? Watson, Philip A. // International Journal of Prosthodontics;Sep/Oct1998, Vol. 11 Issue 5, p513 

    Purpose: Prosthodontic components for implant treatment have been developed with minimal reported scientific investigation. This paper aims to highlight a number of problems caused by this approach to the development and marketing of prosthodontic components and to suggest solutions. Conclusion:...

  • Lingualized occlusion in implant dentistry. Reitz, John V. // Quintessence International;Mar1994, Vol. 25 Issue 3, p177 

    Occlusal requirements for implant prosthodontics, as well as the advantages and disadvantages of two occlusal schemes are discussed. Based on the requirements of fixed reconstruction, the concept of lingualized occlusion with anterior guidance is presented as an ideal occlusal scheme for many...

  • Relining a metal denture base: A clinical report. Pasam, Nirmala; Hallikerimath, R. B.; Gangadhar, S. A. // Journal of Indian Prosthodontic Society;Mar2006, Vol. 6 Issue 1, p51 

    A conventional complete denture can be a successful treatment for many edentulous patients, but situations may arise, particularly in the mandible, where they do not satisfy the patient's need. The problem of denture breakage for one reason or another, is as old as the denture service itself....

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics