TITLE

Contemporary Cruciate-Retaining Total Knee Arthroplasty with a Pegged Tibia! Baseplate: Results at a Minimum of Ten Years

AUTHOR(S)
Barrington, John W.; Sah, Alexander; Malchau, Henrik; Burke, Dennis W.
PUB. DATE
April 2009
SOURCE
Journal of Bone & Joint Surgery, American Volume;Apr2009, Vol. 91-A Issue 4, p874
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: A total knee arthroplasty with a four-peg tibial baseplate is an uncommonly used contemporary design. Potential advantages of this baseplate include preservation of host bone, compatibility with minimally invasive techniques, and easier removal with revision techniques. The purpose of this study was to determine the long-term results of a contemporary total knee arthroplasty that included a four-peg tibial baseplate. Methods: From February 1995 to December 1996, 127 total knee arthroplasties were performed by one surgeon in 115 patients with an average age of seventy years. Clinical and radiographic evaluations were performed with use of the Knee Society scoring system at a minimum often years following replacement. Complications were identified by means of chart review and screening for readmission at surrounding institutions. Results: At the time of follow-up, at a minimum of ten years after the arthroplasty, thirty patients (with thirty-three involved knees) were documented to have died and four patients (with seven involved knees) could not be located. The next-of-kin of the patients who had died directly confirmed that the knee was unrevised at the time of death. Eighty-seven knees in eighty-one patients remained available for evaluation after a minimum often years of follow-up. Two knees had failed: one had a late infection at three years, and one had aseptic loosening at seven years. The rate of survival free of revision at ten years was 97%. Knee Society knee and function scores averaged 94 and 75 points, respectively. None of the remaining knees had radiographic evidence of loosening. Conclusions: This study demonstrated excellent, durable clinical and radiographic results at a minimum of ten years after replacement with this cemented, modular, fixed-bearing, cruciate-retaining total knee prosthesis with a four-peg tibial baseplate. We believe that this design is an acceptable option for total knee arthroplasty. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
37614977

 

Related Articles

  • Glenohumeral Arthrodesis After Failed Prosthetic Shoulder Arthroplasty. Scalise, Jason J.; Iannotti, Joseph P. // Journal of Bone & Joint Surgery, American Volume;Mar2009 Supplement, Vol. 91-A, p30 

    BACKGROUND: While there have been numerous reports concerning glenohumeral arthrodesis for many indications, there is little available information specific to glenohumeral arthrodesis performed after failed prosthetic shoulder arthroplasty. The purpose of this study was to report the outcomes of...

  • Tendon Integrity and Functional Outcome After Arthroscopic Repair of High-Grade Partial-Thickness Supraspinatus Tears. Kamath, Ganesh; Galatz, Leesa M.; Keener, Jay D.; Teefey, Sharlene; Middleton, William; Yamaguchi, Ken // Journal of Bone & Joint Surgery, American Volume;May2009, Vol. 91-A Issue 5, p1055 

    Background: Partial-thickness rotator cuff tears are a common cause of shoulder pain, yet the appropriate surgical treatment is controversial. In particular, very little information is available regarding rotator cuff integrity after operative repair. The purpose of this study was to evaluate...

  • High-Tension Double-Row Footprint Repair Compared with Reduced-Tension Single-Row Repair for Massive Rotator Cuff Tears. Domb, Benjamin G.; Glousman, Ronald E.; Brooks, Adam; Hansen, Matthew; Lee, Thay Q.; Neal S. ElAttrache // Journal of Bone & Joint Surgery, American Volume;Nov2008 Supplement 4, Vol. 90-A, p35 

    The article reports on the results of research which was conducted in an effort to compare the biomechanical behavior of high tension double row repair compared with reduced tension single row repair in the treatment of massive rotator cuff tears. A discussion of the challenges that a massive...

  • Cost-Effectiveness of Antibiotic-Impregnated Bone Cement Used in Primary Total Hip Arthroplasty. Cummins, Justin S.; Tomek, Ivan M.; Kantor, Stephen R.; Furnes, Ove; Engesæter, Lars Birger; Finlayson, Samuel R. G. // Journal of Bone & Joint Surgery, American Volume;Mar2009, Vol. 91-A Issue 3, p634 

    Background: Antibiotic-impregnated bone cement is infrequently used in the United States for primary total hip arthroplasty because of concerns about cost, performance, and the possible development of antibiotic resistance and because it has been approved only for use in revision arthroplasty...

  • Computer-Assisted Minimally Invasive Total Knee Arthroplasty Compared with Standard Total Knee Arthroplasty. Dutton, Andrew Quoc; Seng-Jin Yeo // Journal of Bone & Joint Surgery, American Volume;Mar2009 Supplement, Vol. 91-A, p116 

    BACKGROUND: There is little information on the feasibility of computer navigation when using a minimally invasive approach for total knee arthroplasty, during which the anatomic landmarks for registration may be obscured. The purpose of the present study was to determine the radiographic...

  • Computer-Assisted Surgical Navigation Does Not Improve the Alignment and Orientation of the Components in Total Knee Arthroplasty. Young-Hoo Kim; Jun-Shik Kim; Yoowang Choi; Oh-Ryong Kwon // Journal of Bone & Joint Surgery, American Volume;Jan2009, Vol. 91-A Issue 1, p14 

    Background: Whether total knee arthroplasty with use of computer-assisted surgical navigation can improve the limb and component alignment is a matter of debate. We hypothesized that total knee arthroplasty with use of computer-assisted surgical navigation is superior to conventional total knee...

  • Imageless Navigation in Hip Resurfacing: Avoiding Component Malposition During the Surgeon Learning Curve. Romanowski, James R.; Swank, Michael L. // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p65 

    Background: Studies suggest that hip arthroplasty procedures performed in specialty hospitals or by physicians in practices with a high surgical volume are associated with a decreased rate of adverse outcomes related to component malpositioning. Little is known, however, about the influence of...

  • Does Computer-Assisted Surgery Improve Accuracy and Decrease the Learning Curve in Hip Resurfacing? A Radiographic Analysis. Seyler, Thorsten M.; Lai, Lawrence P.; Sprinkle, Denise I.; Ward, William G.; Jinnah, Riyaz H. // Journal of Bone & Joint Surgery, American Volume;Aug2008 Supplement 3, Vol. 90-A, p71 

    Background: Hip resurfacing is a technically demanding procedure in which accurate positioning of the femoral component is critical to the avoidance of early implant failures. The purpose of this study was to assess the accuracy of computer-assisted placement of the femoral component and to...

  • A Nonlocking End Screw Can Decrease Fracture Risk Caused by Locked Plating in the Osteoporotic Diaphysis. Bottlang, Michael; Doornink, Josef; Byrd, Gregory D.; Fitzpatrick, Daniel C.; Madey, Steven M. // Journal of Bone & Joint Surgery, American Volume;Mar2009, Vol. 91-A Issue 3, p620 

    Background: Locking plates transmit load through fixed-angle locking screws instead of relying on plate-to-bone compression. Therefore, locking screws may induce higher stress at the screw-bone interface than that seen with conventional nonlocked plating. This study investigated whether locked...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics